The BECKHOFF EPP6002-0002 is a 2-channel serial interface EtherCAT P Box designed to integrate serial end devices directly into an EtherCAT P network. This compact and rugged module enables the direct connection of devices utilizing RS232, RS485, or RS422 interfaces, making it highly versatile for distributed data transmission in decentralized industrial automation environments.

By employing EtherCAT P technology, the BECKHOFF EPP6002-0002 combines high-speed communication and power supply (both system/sensor supply Us and peripheral voltage Up for actuators) into a single, standardized 4-wire cable. This design minimizes cabling complexity, reduces installation footprints, and eliminates the need for separate local power supplies for connected serial devices.

Features

  • Two independent serial channels with individually selectable interfaces for RS232, RS422, or RS485.
  • Direct EtherCAT P interface using two shielded, P-coded M8 screw-type connectors.
  • Integrated data buffering with an 864-byte receive buffer and a 128-byte transmit buffer per channel.
  • Configurable data transfer rates ranging from 300 to 115,200 baud, with 9600 baud preset out of the box.
  • Onboard auxiliary sensor supply providing +5 V DC at 20 mA per channel to power connected serial peripherals.
  • Rugged polyamide housing featuring IP65, IP66, and IP67 ingress protection for direct machine mounting without a control cabinet.

Applications

  • Decentralized integration of serial barcode scanners, barcode readers, and RFID systems.
  • Direct connection of industrial weighing scales, laboratory balances, and measurement sensors.
  • Interfacing with serial displays, operator panels, and legacy drive controllers.
  • Distributed serial data acquisition across long distances in harsh environmental conditions.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model EPP6002-0002
Product Type EtherCAT P Box (Serial Interface)
Number of Channels 2
Supported Interfaces RS232, RS485, RS422 (Individually selectable)

Electrical and Power

Parameter Specification
Nominal Voltage 24 V DC (-15% / +20%)
Current Consumption (from Us) Typ. 100 mA
Sensor Supply Voltage +5 V DC
Sensor Supply Current 20 mA per channel
Electrical Isolation 500 V

Communication

Parameter Specification
Protocol EtherCAT
Data Transfer Rates 300 to 115,200 baud (9600 baud preset)
Data Buffer 864 bytes receive buffer, 128 bytes transmit buffer
Max Cable Length (RS232) 15 m
Max Cable Length (RS422/RS485) Approx. 1000 m
Bit Distortion Less than 3%

Connection and Mechanical

Parameter Specification
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Connection Method (Signals) M12 x 1, 5-pin, A-coded
Housing Material Polyamide PA6
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Installation 2 x fixing holes, 3.5 mm diameter for M3 mounting
Weight Approx. 165 g

Environmental and Standards

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE, UL

Connections / Interfaces

Interface Type Function
EtherCAT P (M8, P-coded) Input and output connections combining EtherCAT communication and unit power (Us/Up).
Serial Ports (M12, 5-pin, A-coded) Connects serial end devices (TxD, RxD, GND, and optional +5 V sensor supply).

Installation Guidelines

  1. Ensure the entire industrial network is de-energized before mounting or servicing the system.
  2. Mount the module directly to the machine frame or mounting plate using two M3 screws through the 3.5 mm fixing holes.
  3. Connect the EtherCAT P network lines using only shielded, P-coded M8 connectors to prevent alignment and voltage issues.
  4. Verify that the serial devices are wired correctly according to their interface type (RS232, RS422, or RS485) into the A-coded M12 ports.
  5. Tighten all cable connections to the specified torque to guarantee full IP65/66/67 ingress protection. Install sealing caps on any unused ports.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Which serial communication standards does the BECKHOFF EPP6002-0002 support?
The BECKHOFF EPP6002-0002 supports RS232, RS485, and RS422 communication standards. Each of the two channels can be configured and selected individually to match the electrical characteristics of your serial end device.
How is the BECKHOFF EPP6002-0002 powered?
The BECKHOFF EPP6002-0002 is powered via the EtherCAT P line using standard M8 P-coded connectors. This single cable carries both the high-speed EtherCAT communication and the required operating and peripheral voltages (Us/Up), eliminating the need for separate local supply cabling.
Can the BECKHOFF EPP6002-0002 provide power to connected serial sensors?
Yes, the BECKHOFF EPP6002-0002 features an integrated auxiliary sensor supply. It provides +5 V DC at up to 20 mA per channel to power low-power serial sensors or peripherals directly from the module.
What is the physical protection level of the BECKHOFF EPP6002-0002?
The BECKHOFF EPP6002-0002 is housed in a rugged polyamide enclosure rated for IP65, IP66, and IP67 protection. This design allows it to be mounted directly on machinery in dusty or wet environments without requiring a protective control cabinet.
Reviews

EPP6002-0002

Stock & lead time on request

Call
1 of 1

BECKHOFF EPP6002-0002 EtherCAT P Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPP6002-0002

  • Country of origin:Germany

  • Product Type: EtherCAT P Boxes

  • Payment: T/T, Western Union

  • Weight: 165g

  • Dimensions: 30 mm x 126 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF EPP6002-0002 is a 2-channel serial interface EtherCAT P Box designed to integrate serial end devices directly into an EtherCAT P network. This compact and rugged module enables the direct connection of devices utilizing RS232, RS485, or RS422 interfaces, making it highly versatile for distributed data transmission in decentralized industrial automation environments.

By employing EtherCAT P technology, the BECKHOFF EPP6002-0002 combines high-speed communication and power supply (both system/sensor supply Us and peripheral voltage Up for actuators) into a single, standardized 4-wire cable. This design minimizes cabling complexity, reduces installation footprints, and eliminates the need for separate local power supplies for connected serial devices.

Features

  • Two independent serial channels with individually selectable interfaces for RS232, RS422, or RS485.
  • Direct EtherCAT P interface using two shielded, P-coded M8 screw-type connectors.
  • Integrated data buffering with an 864-byte receive buffer and a 128-byte transmit buffer per channel.
  • Configurable data transfer rates ranging from 300 to 115,200 baud, with 9600 baud preset out of the box.
  • Onboard auxiliary sensor supply providing +5 V DC at 20 mA per channel to power connected serial peripherals.
  • Rugged polyamide housing featuring IP65, IP66, and IP67 ingress protection for direct machine mounting without a control cabinet.

Applications

  • Decentralized integration of serial barcode scanners, barcode readers, and RFID systems.
  • Direct connection of industrial weighing scales, laboratory balances, and measurement sensors.
  • Interfacing with serial displays, operator panels, and legacy drive controllers.
  • Distributed serial data acquisition across long distances in harsh environmental conditions.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model EPP6002-0002
Product Type EtherCAT P Box (Serial Interface)
Number of Channels 2
Supported Interfaces RS232, RS485, RS422 (Individually selectable)

Electrical and Power

Parameter Specification
Nominal Voltage 24 V DC (-15% / +20%)
Current Consumption (from Us) Typ. 100 mA
Sensor Supply Voltage +5 V DC
Sensor Supply Current 20 mA per channel
Electrical Isolation 500 V

Communication

Parameter Specification
Protocol EtherCAT
Data Transfer Rates 300 to 115,200 baud (9600 baud preset)
Data Buffer 864 bytes receive buffer, 128 bytes transmit buffer
Max Cable Length (RS232) 15 m
Max Cable Length (RS422/RS485) Approx. 1000 m
Bit Distortion Less than 3%

Connection and Mechanical

Parameter Specification
Bus Interface 2 x M8 socket, shielded, screw type, P-coded
Connection Method (Signals) M12 x 1, 5-pin, A-coded
Housing Material Polyamide PA6
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Installation 2 x fixing holes, 3.5 mm diameter for M3 mounting
Weight Approx. 165 g

Environmental and Standards

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE, UL

Connections / Interfaces

Interface Type Function
EtherCAT P (M8, P-coded) Input and output connections combining EtherCAT communication and unit power (Us/Up).
Serial Ports (M12, 5-pin, A-coded) Connects serial end devices (TxD, RxD, GND, and optional +5 V sensor supply).

Installation Guidelines

  1. Ensure the entire industrial network is de-energized before mounting or servicing the system.
  2. Mount the module directly to the machine frame or mounting plate using two M3 screws through the 3.5 mm fixing holes.
  3. Connect the EtherCAT P network lines using only shielded, P-coded M8 connectors to prevent alignment and voltage issues.
  4. Verify that the serial devices are wired correctly according to their interface type (RS232, RS422, or RS485) into the A-coded M12 ports.
  5. Tighten all cable connections to the specified torque to guarantee full IP65/66/67 ingress protection. Install sealing caps on any unused ports.
Loading product navigation…

Which serial communication standards does the BECKHOFF EPP6002-0002 support?

The BECKHOFF EPP6002-0002 supports RS232, RS485, and RS422 communication standards. Each of the two channels can be configured and selected individually to match the electrical characteristics of your serial end device.

How is the BECKHOFF EPP6002-0002 powered?

The BECKHOFF EPP6002-0002 is powered via the EtherCAT P line using standard M8 P-coded connectors. This single cable carries both the high-speed EtherCAT communication and the required operating and peripheral voltages (Us/Up), eliminating the need for separate local supply cabling.

Can the BECKHOFF EPP6002-0002 provide power to connected serial sensors?

Yes, the BECKHOFF EPP6002-0002 features an integrated auxiliary sensor supply. It provides +5 V DC at up to 20 mA per channel to power low-power serial sensors or peripherals directly from the module.

What is the physical protection level of the BECKHOFF EPP6002-0002?

The BECKHOFF EPP6002-0002 is housed in a rugged polyamide enclosure rated for IP65, IP66, and IP67 protection. This design allows it to be mounted directly on machinery in dusty or wet environments without requiring a protective control cabinet.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...