1 of 1

BECKHOFF EPP9001-0060 EtherCAT P/EtherCAT Connector

BECKHOFF EPP9001-0060 EtherCAT P/EtherCAT Connector

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPP9001-0060

  • Country of origin:Germany

  • Product Type: EtherCAT P/EtherCAT connector

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 30 mm x 86 mm x 22 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The EPP9001-0060 is a specialized EtherCAT P to EtherCAT converter designed to bridge EtherCAT P infrastructure with standard EtherCAT devices. This module functions as an interface bridge that separates the combined data and power lines of EtherCAT P into an EtherCAT data stream and a dedicated 24 V DC power feed. Housed in a robust, IP65/66/67-rated PA6 (polyamide) casing, this EtherCAT connector is ideal for decentralized machine-mounting environments where power distribution and data communication need to be split for legacy or non-P EtherCAT hardware.

Features

  • EtherCAT P to EtherCAT converter functionality
  • Integrated power decoupling (separates 24 V DC power from EtherCAT P stream)
  • Robust M8 shielded, screw-type connection interfaces
  • IP65/66/67 protection rating for harsh industrial environments
  • Compact form factor (30 mm x 86 mm x 22 mm)
  • Reliable operation from -25 to +60 Celsius
  • Simplified integration for mixed EtherCAT P and standard EtherCAT topologies

Technical Specifications

Feature Specification
Manufacturer BECKHOFF
Part Number EPP9001-0060
Protocol EtherCAT P/EtherCAT
Bus Interface 1 x M8 P-coded (IN), 1 x M8 (OUT)
Nominal Voltage 24 V DC (-15 %/+20 %)
Total Current max. 3 A per US and UP
Protection Rating IP65/66/67
Weight approx. 90 g
Dimensions (W x H x D) 30 mm x 86 mm x 22 mm
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Use the two 3.5 mm diameter fixing holes with M3 screws to mount the module onto the machine frame. The variable installation position allows for optimal cable routing.
  • Connections: The EtherCAT P input uses a P-coded M8 socket, while the EtherCAT output uses a standard M8 socket. Ensure cables are fully seated and screwed tight to maintain IP67 sealing.
  • Power Management: Note that the module supports a maximum feed-in of 3 A per US (System Power) and UP (Peripheral Power). Ensure the power budget of downstream devices does not exceed these values.
  • Grounding: As the module is shielded, ensure the mounting surface provides a good electrical connection to ground, or utilize the shield path through the M8 connectors to mitigate electromagnetic noise.

What is the primary role of the EPP9001-0060?

It serves as a converter that splits the combined EtherCAT P signal (data + power) into a standard EtherCAT data stream and a 24 V DC power feed for standard EtherCAT devices.

Does this module require a separate power supply?

No, it receives power from the EtherCAT P line (US and UP) and distributes it to the output, up to a maximum of 3 A.

Can this be used in environments with dust or water spray?

Yes, with an IP65/66/67 rating, it is protected against dust ingress and high-pressure water jets, making it suitable for wet or dirty industrial environments.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...