Product Description

Description

The BECKHOFF EQ3174-0002 is a 4-channel analog input EtherCAT Box designed for direct acquisition of voltage or current signals in harsh washdown environments. Built with a high-grade stainless steel housing featuring a Hygienic Design, this device is engineered for industries with strict sanitation and cleanliness requirements, such as food processing, packaging, pharmaceuticals, and chemical manufacturing.

This EtherCAT Box permits individual parameterization of each channel, supporting signal ranges of -10 to +10 V, 0 to +10 V, 0 to 20 mA, and 4 to 20 mA. High-resolution 16-bit analog-to-digital conversion, combined with distributed clocks capability, ensures precise synchronization and high-speed data acquisition directly at the machine level, eliminating the need for protective control cabinets.

Features

  • Four analog inputs, individually parameterizable for voltage or current signals.
  • High-grade stainless steel housing (Hygienic Design) with IP69K protection rating for high-pressure clean-in-place (CIP) and washdown applications.
  • High-resolution 16-bit measurement with rapid conversion times of approximately 100 microseconds.
  • Distributed Clocks (DC) support for highly precise synchronized time-stamped analog measurements.
  • M12 connection technology for secure sensor connectivity and M8 connections for EtherCAT and power.

Applications

  • Food, beverage, and packaging machinery requiring frequent chemical washdowns.
  • Pharmaceutical and biochemical processing plants with strict hygienic standards.
  • Direct machine-mount analog signal acquisition in humid, wet, or corrosive environments.

Technical Specifications

General Specifications

Parameter Specification
Manufacturer BECKHOFF
Model EQ3174-0002
Housing Material Stainless steel (Hygienic Design)
Protection Rating IP69K (conforms to EN 60529)
Dimensions (W x H x D) 39 mm x 160 mm x 43 mm
Installation 2 fixing lugs for M5 screws

Electrical and I/O Data

Parameter Specification
Number of Inputs 4
Signal Type -10/0...+10 V | 0/4...20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Conversion Time ~ 100 microseconds
Input Filter Limit Frequency 5 kHz
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Common-Mode Voltage UCM max. 35 V
Measurement Uncertainty < ±0.3% (relative to full scale value)
Sensor Supply From load supply voltage UP
Current Consumption from US 120 mA
Nominal Voltage 24 V DC (-15% / +20%)
Electrical Isolation 500 V

Connection and Communication

Parameter Specification
Protocol EtherCAT
Bus Interface Connection 2 x M8 socket, shielded, screw type
Input Connections M12 x 1, 5-pin, A-coded
Power Supply Feed Connection 1 x M8 male socket, 4-pin
Power Supply Downstream Connection 1 x M8 female socket, 4-pin
Distributed Clocks (DC) Yes

Environmental and Standards

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals/Markings CE, UL

Installation Guidelines

  1. Verify that the plant and all related power sources are de-energized before mounting or wiring.
  2. Securely mount the module to the machine frame using the two fixing lugs with M5 screws.
  3. Ensure all M12 and M8 cabling connectors are tightened to the recommended torque specifications to maintain the IP69K sealing integrity.
  4. Verify correct potential grouping and sensor power supply connections before energizing the module.
  5. Configure the input channel parameters (voltage or current range) within the TwinCAT System Manager software prior to commissioning.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary application of the BECKHOFF EQ3174-0002?
The BECKHOFF EQ3174-0002 is designed for direct machine-mount analog data acquisition in hygienic and washdown areas, such as food processing and pharmaceuticals, where high-pressure cleaning is performed.
What input signals are supported by the BECKHOFF EQ3174-0002?
The BECKHOFF EQ3174-0002 supports voltage signals of -10 to +10 V (or 0 to +10 V) and current signals of 0 to 20 mA (or 4 to 20 mA), which are individually parameterizable for each of its 4 channels.
What protection rating does the housing of the BECKHOFF EQ3174-0002 offer?
The BECKHOFF EQ3174-0002 features a high-grade stainless steel housing with an IP69K protection rating, making it completely dust-tight and resistant to high-pressure, high-temperature washdowns.
Does the BECKHOFF EQ3174-0002 support Distributed Clocks (DC)?
Yes, the BECKHOFF EQ3174-0002 fully supports EtherCAT Distributed Clocks (DC), enabling highly precise and synchronized time-stamped analog measurements.
Reviews

EQ3174-0002

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF EQ3174-0002 Hygienic Analog Input EtherCAT Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EQ3174-0002

  • Country of origin:Germany

  • Product Type: EtherCAT Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 39 mm x 160 mm x 43 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF EQ3174-0002 is a 4-channel analog input EtherCAT Box designed for direct acquisition of voltage or current signals in harsh washdown environments. Built with a high-grade stainless steel housing featuring a Hygienic Design, this device is engineered for industries with strict sanitation and cleanliness requirements, such as food processing, packaging, pharmaceuticals, and chemical manufacturing.

This EtherCAT Box permits individual parameterization of each channel, supporting signal ranges of -10 to +10 V, 0 to +10 V, 0 to 20 mA, and 4 to 20 mA. High-resolution 16-bit analog-to-digital conversion, combined with distributed clocks capability, ensures precise synchronization and high-speed data acquisition directly at the machine level, eliminating the need for protective control cabinets.

Features

  • Four analog inputs, individually parameterizable for voltage or current signals.
  • High-grade stainless steel housing (Hygienic Design) with IP69K protection rating for high-pressure clean-in-place (CIP) and washdown applications.
  • High-resolution 16-bit measurement with rapid conversion times of approximately 100 microseconds.
  • Distributed Clocks (DC) support for highly precise synchronized time-stamped analog measurements.
  • M12 connection technology for secure sensor connectivity and M8 connections for EtherCAT and power.

Applications

  • Food, beverage, and packaging machinery requiring frequent chemical washdowns.
  • Pharmaceutical and biochemical processing plants with strict hygienic standards.
  • Direct machine-mount analog signal acquisition in humid, wet, or corrosive environments.

Technical Specifications

General Specifications

Parameter Specification
Manufacturer BECKHOFF
Model EQ3174-0002
Housing Material Stainless steel (Hygienic Design)
Protection Rating IP69K (conforms to EN 60529)
Dimensions (W x H x D) 39 mm x 160 mm x 43 mm
Installation 2 fixing lugs for M5 screws

Electrical and I/O Data

Parameter Specification
Number of Inputs 4
Signal Type -10/0...+10 V | 0/4...20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Conversion Time ~ 100 microseconds
Input Filter Limit Frequency 5 kHz
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Common-Mode Voltage UCM max. 35 V
Measurement Uncertainty < ±0.3% (relative to full scale value)
Sensor Supply From load supply voltage UP
Current Consumption from US 120 mA
Nominal Voltage 24 V DC (-15% / +20%)
Electrical Isolation 500 V

Connection and Communication

Parameter Specification
Protocol EtherCAT
Bus Interface Connection 2 x M8 socket, shielded, screw type
Input Connections M12 x 1, 5-pin, A-coded
Power Supply Feed Connection 1 x M8 male socket, 4-pin
Power Supply Downstream Connection 1 x M8 female socket, 4-pin
Distributed Clocks (DC) Yes

Environmental and Standards

Parameter Specification
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals/Markings CE, UL

Installation Guidelines

  1. Verify that the plant and all related power sources are de-energized before mounting or wiring.
  2. Securely mount the module to the machine frame using the two fixing lugs with M5 screws.
  3. Ensure all M12 and M8 cabling connectors are tightened to the recommended torque specifications to maintain the IP69K sealing integrity.
  4. Verify correct potential grouping and sensor power supply connections before energizing the module.
  5. Configure the input channel parameters (voltage or current range) within the TwinCAT System Manager software prior to commissioning.
Loading product navigation…

What is the primary application of the BECKHOFF EQ3174-0002?

The BECKHOFF EQ3174-0002 is designed for direct machine-mount analog data acquisition in hygienic and washdown areas, such as food processing and pharmaceuticals, where high-pressure cleaning is performed.

What input signals are supported by the BECKHOFF EQ3174-0002?

The BECKHOFF EQ3174-0002 supports voltage signals of -10 to +10 V (or 0 to +10 V) and current signals of 0 to 20 mA (or 4 to 20 mA), which are individually parameterizable for each of its 4 channels.

What protection rating does the housing of the BECKHOFF EQ3174-0002 offer?

The BECKHOFF EQ3174-0002 features a high-grade stainless steel housing with an IP69K protection rating, making it completely dust-tight and resistant to high-pressure, high-temperature washdowns.

Does the BECKHOFF EQ3174-0002 support Distributed Clocks (DC)?

Yes, the BECKHOFF EQ3174-0002 fully supports EtherCAT Distributed Clocks (DC), enabling highly precise and synchronized time-stamped analog measurements.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...