The BECKHOFF ERI2008-0002 is a ruggedized IO-Link box module designed to provide decentralized digital output capabilities in demanding industrial environments. Equipped with eight digital outputs, this device operates as an IO-Link device under the Class B specification, facilitating both control data and auxiliary power transmission over a single connection interface.

Housed in a robust zinc die-cast enclosure, the BECKHOFF ERI2008-0002 provides superior mechanical stability and resistance compared to standard plastic alternatives. It connects to the higher-level IO-Link master via an A-coded M12 connector, while field-level actuators connect directly through space-saving M8 screw-type connection points. This architecture simplifies field installation, reduces cabling requirements, and eliminates the need for protective control cabinets near the machine footprint.

Features

  • Eight digital output channels supporting up to 0.5 A per channel from the auxiliary power contact.
  • Rugged zinc die-cast housing engineered for extreme mechanical resistance in heavy-use environments.
  • High IP65, IP66, and IP67 protection ratings, ensuring dust-tight performance and water immersion resistance.
  • IO-Link V1.1 Class B specification compliance with COM 3 transmission rates up to 230.4 kbaud.
  • Individually short-circuit proof output channels with built-in diagnostic and protection capabilities.
  • Complete electrical isolation between the L+ logic supply and the P24 auxiliary load supply.

Applications

  • Decentralized actuator control in machine building and automated assembly lines.
  • Applications requiring robust field bus distribution without the use of centralized terminal boxes.
  • Heavy-duty mechanical handling and conveyor systems exposed to vibration, moisture, or particulate matter.
  • Integration with pneumatic valves, contactors, indicators, and small DC motors.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model ERI2008-0002
Product Type IO-Link Box
Housing Material Zinc die-cast
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable (2 fixing holes, 3.5 mm diameter for M3 screws)

IO-Link and Communication

Parameter Specification
Protocol IO-Link
Specification Version IO-Link V1.1, Class B
Data Transfer Rates 230.4 kbaud (COM 3)
Interface Connection 1 x M12 plug, A-coded

Electrical and Outputs

Parameter Specification
Number of Outputs 8 digital outputs
Output Connections M8, screw-type connection
Load Type Ohmic, inductive, lamp load
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (from P24, individually short-circuit proof)
Short-Circuit Current Typical 1.5 A
Current Consumption (Logic) Typical 100 mA from L+
Auxiliary Power Current Typical 20 mA + load
Electrical Isolation L+ / P24: Yes

Physical and Environmental

Parameter Specification
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Weight Approx. 265 g
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals/Markings CE, UL

Connections / Interfaces

Interface or Terminal Function
IO-Link Interface (M12) 1 x M12 plug, A-coded (Class B power and communication connection)
Digital Outputs (M8) 8 x M8 sockets, 3-pin (connection of actuators and field devices)

Installation Guidelines

  1. Verify that the supply voltage matches the nominal range of 24 V DC (-15% / +20%) before connecting any cables.
  2. De-energize all electrical supplies to the system prior to mounting or wiring the IO-Link box.
  3. Securely mount the module directly to the machine frame using two 3.5 mm diameter fixing holes designed for M3 screws. Do not overtighten.
  4. Connect the IO-Link Class B cable to the A-coded M12 plug interface, ensuring the connection is threaded tightly to maintain the specified IP protection level.
  5. Attach the actuator wiring to the M8 screw-type ports. Unused M8 or M12 connections must be sealed with appropriate protective caps to preserve IP65/66/67 integrity.
  6. Verify correct operation through the host controller software configuration, monitoring current draw and checking for short-circuit faults.

FAQ

What is the primary function of the BECKHOFF ERI2008-0002?

The BECKHOFF ERI2008-0002 is a decentralized IO-Link box module equipped with 8 digital outputs (24 V DC, 0.5 A) housed in a durable, zinc die-cast casing to control field actuators directly in harsh environments.

What connection technology does the BECKHOFF ERI2008-0002 use for I/O and communication?

The BECKHOFF ERI2008-0002 features 8 x M8 screw-type connections for its digital outputs and a single A-coded M12 plug for the IO-Link host communication interface.

What IO-Link specification and class does the BECKHOFF ERI2008-0002 support?

The BECKHOFF ERI2008-0002 complies with the IO-Link V1.1 Class B specification and supports COM 3 data transfer rates up to 230.4 kbaud.

How is the BECKHOFF ERI2008-0002 protected against environmental elements?

The BECKHOFF ERI2008-0002 features a robust die-cast zinc housing with an IP65, IP66, and IP67 protection rating, making it highly resistant to dust, high-pressure water jets, and temporary immersion.

Does the BECKHOFF ERI2008-0002 offer channel-level safety or isolation?

Yes, the BECKHOFF ERI2008-0002 provides electrical isolation between the L+ logic supply and the P24 auxiliary load supply, and each of its 8 digital outputs is individually short-circuit proof.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.