BECKHOFF

BECKHOFF FM3312-B310-1010 12-Channel Thermocouple Fieldbus Module with PROFIBUS DP

SKU FM3312-B310-1010

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: FM3312-B310-1010
  • Origin Germany
  • Product Type: Fieldbus Modules
  • Payment: T/T, Western Union
  • Weight: 1.03 kg
  • Dimensions: 150 mm x 52 mm x 129 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF FM3312-B310-1010 is a high-density, decentralized fieldbus module designed for the direct acquisition of up to 12 thermocouple temperature measurement channels. Operating as a node on a PROFIBUS DP network, this module facilitates remote temperature monitoring without requiring a separate control cabinet. It directly accommodates Type J and K thermocouple sensors, as well as millivolt (mV) linear voltage signals, making it suitable for distributed thermal sensing across industrial machinery and plant environments.

The module features a rugged mechanical design, incorporating a Han24E connector interface in a Type B add-on housing with gold-plated contacts. This construction ensures stable low-voltage signal transmission even in harsh physical environments. Communication with the higher-level controller is handled via a high-speed PROFIBUS DP interface, supporting data transfer rates of up to 12 Mbaud. Parameter configuration and diagnostics can be performed using the Beckhoff KS2000 software tool or directly via the fieldbus controller.

To maintain high signal integrity in noisy electrical environments, the module features electrical isolation between the measurement channels and the control voltage, as well as between the control electronics and the PROFIBUS fieldbus interface. Configurable input filter variations allow engineers to tune the module's response characteristics according to the specific environmental noise and thermal dynamics of the application.

Features

  • 12 independent thermocouple input channels supporting Type J and Type K sensors.
  • Direct millivolt (mV) linear voltage measurement mode.
  • Integrated PROFIBUS DP fieldbus interface with transfer rates up to 12 Mbaud.
  • Heavy-duty Type B housing featuring a Han24E pin insert with hard gold-plated contacts.
  • Configurable input signal filtering with five distinct variations.
  • High-density 2-wire thermocouple connection scheme.
  • Direct configuration via the KS2000 software interface or the master PLC.
  • Electrical isolation of 500 V between input channels and control voltage.

Applications

  • Decentralized multi-point temperature measurement in processing machinery.
  • Extrusion lines and plastic injection molding systems.
  • Thermal monitoring of industrial furnaces and heat treatment equipment.
  • Distributed environmental testing and temperature tracking in remote field sites.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Number FM3312-B310-1010
Fieldbus Interface PROFIBUS DP
Data Transfer Rates Max. 12 Mbaud
Thermocouple Channels 12
Sensor Support Type J, Type K, mV voltage measurement
Measuring Range -10 to +900 degC
Resolution 0.1 degC per digit
Conversion Time Approx. 250 ms
Measurement Error < ±0.5% of full scale value
Input Filter 5 configurable variations
Power Supply Voltage 24 V DC (-15% / +20%)
Current Consumption Typ. 90 mA, max. 120 mA
Process Image Width Input: 4 x 16-bit data (optional: 4 x 8-bit control/status)
Electrical Isolation Channels/Control Voltage: 500 V; Control Voltage/Fieldbus: 100 V (PROFIBUS)
Housing Type Type B add-on housing AGG with locking bracket
Housing Pin Insert Han24E
Contact Plating Hard gold-plated
Dimensions (W x H x D) 150 mm x 52 mm x 129 mm
Net Weight 1030 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating Housing IP65; PROFIBUS connector IP67 (when mated)
Approvals / Markings CE, UL

Connections / Interfaces

Interface / Connection Point Function
Fieldbus Port DIN 45322, 6-pin screw-type connector for PROFIBUS DP
Thermocouple Inputs Han24E / Han64D heavy-duty industrial plug-in connection, 2-wire scheme
Power Supply Connection Internal control voltage terminals (24 V DC supply)

Installation Guidelines

  1. Ensure that all local electrical and control systems are fully de-energized before beginning physical installation.
  2. Mount the module onto the designated mounting surface using the structural AGG add-on housing and locking bracket assembly.
  3. Connect the 24 V DC power supply lines, ensuring correct polarity and proper grounding practices.
  4. Route and plug in the heavy-duty thermocouple wiring harness via the Han24E industrial insert, ensuring gold-plated pins are clean and free of contaminants. Keep thermocouple cable lengths under 10 meters to prevent signal degradation.
  5. Connect the PROFIBUS DP communications cable using the 6-pin DIN 45322 screw-type connector. Use certified shielded PROFIBUS cables to prevent EMI.
  6. After hardware inspection, apply power and use the KS2000 tool or the PROFIBUS controller to set the appropriate sensor type (Type J, K, or mV) and configure the preferred digital input filter variation.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What sensor types are supported by the BECKHOFF FM3312-B310-1010?
The BECKHOFF FM3312-B310-1010 fieldbus module supports direct connection of Type J and Type K thermocouples, as well as general millivolt (mV) linear voltage measurements.
How is the thermocouple connection physically wired on this module?
The BECKHOFF FM3312-B310-1010 utilizes a rugged Han24E heavy-duty industrial plug-in connector with gold-plated contacts, configured for 2-wire thermocouple connections.
What is the maximum cable length allowed for thermocouple sensors on the BECKHOFF FM3312-B310-1010?
To ensure measurement accuracy and maintain signal integrity, the maximum recommended cable length for thermocouple sensors connected to the BECKHOFF FM3312-B310-1010 is 10 meters.
How do you configure the input filters on the BECKHOFF FM3312-B310-1010?
The BECKHOFF FM3312-B310-1010 features five configurable input filter variations which can be set using the Beckhoff KS2000 configuration software or directly through parameterization from the PROFIBUS DP master controller.
What are the protection ratings for the BECKHOFF FM3312-B310-1010 housing?
The main housing of the BECKHOFF FM3312-B310-1010 is rated to IP65, and the PROFIBUS fieldbus interface connector achieves an IP67 protection rating when fully and correctly mated.
Reviews

FM3312-B310-1010

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF FM3312-B310-1010 12-Channel Thermocouple Fieldbus Module with PROFIBUS DP

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: FM3312-B310-1010

  • Country of origin:Germany

  • Product Type: Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 1030g

  • Dimensions: 150 mm x 52 mm x 129 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF FM3312-B310-1010 is a high-density, decentralized fieldbus module designed for the direct acquisition of up to 12 thermocouple temperature measurement channels. Operating as a node on a PROFIBUS DP network, this module facilitates remote temperature monitoring without requiring a separate control cabinet. It directly accommodates Type J and K thermocouple sensors, as well as millivolt (mV) linear voltage signals, making it suitable for distributed thermal sensing across industrial machinery and plant environments.

The module features a rugged mechanical design, incorporating a Han24E connector interface in a Type B add-on housing with gold-plated contacts. This construction ensures stable low-voltage signal transmission even in harsh physical environments. Communication with the higher-level controller is handled via a high-speed PROFIBUS DP interface, supporting data transfer rates of up to 12 Mbaud. Parameter configuration and diagnostics can be performed using the Beckhoff KS2000 software tool or directly via the fieldbus controller.

To maintain high signal integrity in noisy electrical environments, the module features electrical isolation between the measurement channels and the control voltage, as well as between the control electronics and the PROFIBUS fieldbus interface. Configurable input filter variations allow engineers to tune the module's response characteristics according to the specific environmental noise and thermal dynamics of the application.

Features

  • 12 independent thermocouple input channels supporting Type J and Type K sensors.
  • Direct millivolt (mV) linear voltage measurement mode.
  • Integrated PROFIBUS DP fieldbus interface with transfer rates up to 12 Mbaud.
  • Heavy-duty Type B housing featuring a Han24E pin insert with hard gold-plated contacts.
  • Configurable input signal filtering with five distinct variations.
  • High-density 2-wire thermocouple connection scheme.
  • Direct configuration via the KS2000 software interface or the master PLC.
  • Electrical isolation of 500 V between input channels and control voltage.

Applications

  • Decentralized multi-point temperature measurement in processing machinery.
  • Extrusion lines and plastic injection molding systems.
  • Thermal monitoring of industrial furnaces and heat treatment equipment.
  • Distributed environmental testing and temperature tracking in remote field sites.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Number FM3312-B310-1010
Fieldbus Interface PROFIBUS DP
Data Transfer Rates Max. 12 Mbaud
Thermocouple Channels 12
Sensor Support Type J, Type K, mV voltage measurement
Measuring Range -10 to +900 degC
Resolution 0.1 degC per digit
Conversion Time Approx. 250 ms
Measurement Error < ±0.5% of full scale value
Input Filter 5 configurable variations
Power Supply Voltage 24 V DC (-15% / +20%)
Current Consumption Typ. 90 mA, max. 120 mA
Process Image Width Input: 4 x 16-bit data (optional: 4 x 8-bit control/status)
Electrical Isolation Channels/Control Voltage: 500 V; Control Voltage/Fieldbus: 100 V (PROFIBUS)
Housing Type Type B add-on housing AGG with locking bracket
Housing Pin Insert Han24E
Contact Plating Hard gold-plated
Dimensions (W x H x D) 150 mm x 52 mm x 129 mm
Net Weight 1030 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating Housing IP65; PROFIBUS connector IP67 (when mated)
Approvals / Markings CE, UL

Connections / Interfaces

Interface / Connection Point Function
Fieldbus Port DIN 45322, 6-pin screw-type connector for PROFIBUS DP
Thermocouple Inputs Han24E / Han64D heavy-duty industrial plug-in connection, 2-wire scheme
Power Supply Connection Internal control voltage terminals (24 V DC supply)

Installation Guidelines

  1. Ensure that all local electrical and control systems are fully de-energized before beginning physical installation.
  2. Mount the module onto the designated mounting surface using the structural AGG add-on housing and locking bracket assembly.
  3. Connect the 24 V DC power supply lines, ensuring correct polarity and proper grounding practices.
  4. Route and plug in the heavy-duty thermocouple wiring harness via the Han24E industrial insert, ensuring gold-plated pins are clean and free of contaminants. Keep thermocouple cable lengths under 10 meters to prevent signal degradation.
  5. Connect the PROFIBUS DP communications cable using the 6-pin DIN 45322 screw-type connector. Use certified shielded PROFIBUS cables to prevent EMI.
  6. After hardware inspection, apply power and use the KS2000 tool or the PROFIBUS controller to set the appropriate sensor type (Type J, K, or mV) and configure the preferred digital input filter variation.
Loading product navigation…

What sensor types are supported by the BECKHOFF FM3312-B310-1010?

The BECKHOFF FM3312-B310-1010 fieldbus module supports direct connection of Type J and Type K thermocouples, as well as general millivolt (mV) linear voltage measurements.

How is the thermocouple connection physically wired on this module?

The BECKHOFF FM3312-B310-1010 utilizes a rugged Han24E heavy-duty industrial plug-in connector with gold-plated contacts, configured for 2-wire thermocouple connections.

What is the maximum cable length allowed for thermocouple sensors on the BECKHOFF FM3312-B310-1010?

To ensure measurement accuracy and maintain signal integrity, the maximum recommended cable length for thermocouple sensors connected to the BECKHOFF FM3312-B310-1010 is 10 meters.

How do you configure the input filters on the BECKHOFF FM3312-B310-1010?

The BECKHOFF FM3312-B310-1010 features five configurable input filter variations which can be set using the Beckhoff KS2000 configuration software or directly through parameterization from the PROFIBUS DP master controller.

What are the protection ratings for the BECKHOFF FM3312-B310-1010 housing?

The main housing of the BECKHOFF FM3312-B310-1010 is rated to IP65, and the PROFIBUS fieldbus interface connector achieves an IP67 protection rating when fully and correctly mated.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...