Bently Nevada

Bently Nevada 168679-01-01-01-02-03-05-01-01-00-02-02 ADRE 408 DSPi Dynamic Signal Processing Instrument

SKU 168679-01-01-01-02-03-05-01-01-00-02-02

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 168679-01-01-01-02-03-05-01-01-00-02-02
  • Origin United States
  • Product Type: Vibration Data Acquisition Systems
  • Payment: T/T, Western Union
  • Weight: 11.5 kg
  • Dimensions: 560 x 460 x 240 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 168679-01-01-01-02-03-05-01-01-00-02-02 ADRE 408 DSPi Dynamic Signal Processing Instrument

Quantity

Product Description

Description

The Bently Nevada 168679-01-01-01-02-03-05-01-01-00-02-02 is a multi-channel ADRE 408 DSPi Dynamic Signal Processing Instrument designed for real-time parallel signal processing, machinery condition monitoring, and advanced vibration data acquisition. The system functions as a digital recorder, spectrum analyzer, signal conditioner, oscilloscope, and filter platform, consolidating complex vibration analysis instrumentation into a single portable or rack-mountable enclosure. This specific build provides a 24-channel dynamic sampling architecture alongside speed, trigger, power supply, and digital replay capabilities for critical turbomachinery and rotating equipment diagnostic testing.

Engineered around a flexible client-server architecture, the 408 DSPi operates either as a standalone data recorder connected to corporate LAN/WAN networks or directly paired with a local host running ADRE Sxp software. The internal 480GB solid-state drive allows continuous high-speed data streaming and event logging independent of an active computer connection. This configuration populated across Slots 1 through 5 supports synchronous and asynchronous sampling across dynamic transducers, phase-reference Keyphasor inputs, and process transmitters without interrupting active data acquisition runs.

Features

  • Multi-Channel Dynamic Processing: Populated with three 8-channel dynamic sampling cards, delivering up to 24 simultaneous dynamic input channels with 24-bit A/D conversion.
  • Dedicated Speed & Trigger Management: Features one 3-channel speed input card supporting proximity, optical, magnetic, and laser tachometer inputs with built-in signal conditioning and buffered outputs.
  • Integrated Transducer Power: Includes a dedicated Transducer Power Supply Card capable of driving positive and negative bias 2-wire constant current sensors or 3-wire proximity probes.
  • Hardware Digital Replay Engine: Slot 5 equipped with a Digital Replay Card (without analog outputs) for offline reprocessing and signal re-conditioning without affecting original sampled dynamic data.
  • Standalone Storage & Networking: Contains an internal 480GB Solid State Drive (SSD) and dual 1000/100Mb Ethernet ports supporting DHCP or fixed IP addressing for network or local operation.
  • Rugged Enclosure & Power Kit: Built in an aluminum chassis with protective powder coating, complete with an external universal AC power supply (90–264 Vac) and hard shipping case for field deployment.
  • CE Compliance: Certified to European standards with CE approval marking.

Applications

  • Field vibration diagnostics and transient data collection during turbomachinery start-up and coast-down operations.
  • Multi-plane balancing analysis using Bently BALANCE software integration.
  • Structural dynamics testing and impact hammer excitation measurement.
  • Test stand validation and factory acceptance testing (FAT) for industrial turbines, compressors, pumps, and gearboxes.
  • Remote machinery condition monitoring across LAN/WAN infrastructure.

Ordering Information

Option Code Hardware / Configuration Selected
Model 168679 ADRE 408 DSPi Dynamic Signal Processing Instrument
Slot #1 (Option A) 01 - 8 Ch Dynamic Sampler Card
Slot #2 (Option B) 01 - 8 Ch Dynamic Sampler Card
Slot #3 (Option C) 01 - 8 Ch Dynamic Sampler Card
Slot #4 (Option D) 02 - 3 Ch Speed Input (KPH) / Trigger Card
Slot #5 (Option E) 03 - Transducer Power Supply Card
Option Slot #5 (Option E/Card) 05 / 01 - Digital Replay Card w/o Analog Output Card
Power Supply (Option F) 01 - 90/264 Vac 47/63Hz Power Supply (US, EU, BR Power Cords)
Carry Case (Option G) 01 - Hard Shipping Case
Metrology Cert (Option H) 00 - None
Rack Mount Kit (Option I) 00 - None
Solid State Drive (Option J) 02 - 480GB Solid State Drive
Approvals (Option K) 02 - CE

Technical Specifications

General

Parameter Specification
Manufacturer Bently Nevada (a Baker Hughes business)
Product Model ADRE 408 DSPi (Part Number 168679)
System Architecture Multi-channel Digital Signal Processing Instrument
Internal Data Storage 480GB Solid State Drive (SSD)
Real-Time Clock Accuracy Battery-backed RTC, 5 seconds/month
Chassis Construction Aluminum chassis with cast aluminum front/rear panels, textured black powder coating
Status Display / Controls Front panel LCD, LED status indicators, tactile switches

Dynamic Sampling (8-Channel Card x 3)

Parameter Specification
Dynamic Inputs 24 channels total (8 single-ended or 4 differential per card, 8 x 4-20mA)
A/D Conversion 24-bit resolution per channel
Single-Ended Input Impedance 742 kΩ
Differential Input Impedance 1.484 MΩ between Sig+ and Sig-
4-20 mA Input Impedance 511 Ω
Maximum Signal Input Range -25 to +25 V DC; 0.7 to 10 V AC
Asynchronous Sampling Rates 128 Hz to 128 kHz (Spans: 50 Hz to 50 kHz)
Synchronous Sampling Rates 16 to 2048 samples/revolution (Sync rate x RPM <= 32 kHz)
Direct Measurement Accuracy ±1% of Full Scale Range (DC to 50 kHz Hi Mode)
Bandpass Filter Options 2, 4, 6, 8 Pole Butterworth (HPF 1 Hz to 25.5 kHz, LPF 10 Hz to 50 kHz)
nX Amplitude & Phase Accuracy ±1% of Full Scale Range, ±3° of input (1 to 120,000 RPM)
Gap Voltage Range Fully programmable between -25 V DC and +25 V DC

Speed Input / Trigger (3-Channel Card)

Parameter Specification
Speed / Keyphasor Inputs 3 single-ended channels
Supported Transducers Proximity, magnetic, optical, laser, force hammer
Speed Range 1 to 120,000 RPM (0.0167 Hz to 2 kHz)
Speed Measurement Accuracy ±0.00915% of period input
Input Impedance 128.9 kΩ
Buffered Outputs 3 channels (Raw, Conditioned Analog, or TTL selectable); Short-circuit protected
Input Multiplier / Divider 3 stages per channel (8 digits pre-decimal, 12 digits post-decimal)

Transducer Power Supply

Parameter Specification
Power Capacity Up to 32 transducers simultaneously
Direct Connections 16 physical connections (8 x -24V DC, 8 x Constant Current)
Voltage Output Ratings -24 V DC (84.5 mA max), +24 V DC (29 mA max)
Constant Current Bias Positive (+3.36 mA) or Negative (-3.30 mA) selectable in blocks of 4
Protection Short-circuit protection and current regulation per output

Communication & Power Supply

Parameter Specification
Ethernet Ports Dual 1000/100Mb RJ45 ports
Network Protocols TCP/IP, DHCP or Fixed IP addressing
External Power Supply Input 90 to 264 Vac, 47 to 63 Hz auto-sensing
Power Supply Output +32 V DC ±5% @ 10 A Max; +5 V DC ±3% @ 600 mA Max

Physical & Environmental

Parameter Specification
408 DSPi Dimensions (L x W x H) 36.1 x 41.0 x 10.0 cm (14.25 x 16.0 x 3.8 in)
External Power Supply Dimensions 18.3 x 13.7 x 9.1 cm (7.2 x 5.4 x 3.6 in)
408 DSPi Weight 9.5 kg (21 lbs) fully populated with 32 channels
Power Supply Weight 1.3 kg (3 lbs)
Operating Temperature 0 degC to +50 degC (+32 degF to +122 degF)
Storage Temperature -30 degC to +80 degC (-22 degF to +176 degF)
Operating Humidity 0% to 95% non-condensing
Operational Vibration / Shock Vibration: 0.25G @ 5-100Hz; Shock: 10G @ 2ms

Connections / Interfaces

Connector / Interface Function
Front Panel SMA Ports Signal inputs for 8-channel dynamic sampling cards
Front Panel Speed BNC/SMA Ports Keyphasor, optical, and speed trigger input channels
Front Panel Keyphasor Terminal Optical transducer power output (+5 V DC) on Channel 3
Rear Panel Transducer Power 24 V DC and Constant Current power output terminal connections
Dual RJ45 Ports Independent primary LAN/WAN connection and local client interface
External DC Input Port High-reliability bayonet-locking connector for 32 V DC supply

Installation Guidelines

  1. Inspect the 408 DSPi instrument, external power supply, input cables, and hard shipping case for shipping damage before setup.
  2. Ensure proper physical placement on a benchtop or within a standard 19-inch rack, ensuring fan inlets remain unobstructed for cooling air flow.
  3. Connect the external power supply using the bayonet-locking DC connector and join the AC line to a 90–264 Vac power outlet.
  4. Connect dynamic signal inputs (proximity probes, accelerometers, or velocity sensors) to the SMA front panel connectors using appropriate adapter cables (SMA to BNC).
  5. Wire speed sensors or Keyphasor proximity drivers to the 3-channel Speed Input card.
  6. If powering sensors directly from the instrument, configure the Transducer Power Supply card switches for the required constant current (positive/negative bias) or -24 V DC settings prior to enabling transducer power.
  7. Connect an Ethernet cable from the primary RJ45 port on the instrument to a host PC or dedicated local network switch.

Configuration Guidelines

  1. Launch ADRE Quick Configuration or ADRE Sxp software on the client machine.
  2. Establish network communication using DHCP auto-discovery or by entering the fixed IP address assigned to the instrument port.
  3. Define the machine train layout, shaft rotational orientation, and sensor mounting angles in the software environment.
  4. Set channel-specific transducer parameters including scale factor (mV/mil, mV/g), coupling type (AC/DC), and full-scale range.
  5. Set up Keyphasor trigger thresholds, edge detection (rising/falling), and multiplier/divider ratios for order tracking.
  6. Download the generated configuration file to the 408 DSPi internal SSD storage.

Commissioning & Replacement Recommendations

  1. Verify sensor gap voltages and channel DC bias readings on the front display or software screen prior to machine start-up.
  2. Initiate a manual sample run from the front panel or client interface to confirm active dynamic sampling across all connected channels.
  3. Before replacing or re-configuring cards, stop active recording runs and back up stored database files from the 480GB internal SSD to an external drive or network host.
  4. When swapping processing cards, ensure power is removed from the unit before removing card retaining screws.

Compliance and Certifications

  • CE Compliance: Conforms to EMC Directive 2014/30/EU (EN 61000-6-2, EN 61000-6-4) and Low Voltage Directive 2014/35/EU.
  • RoHS: Complies with Directive 2011/65/EU.
  • FCC: Complies with Part 15 of FCC Rules for Class A digital devices.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Bently Nevada ADRE 408 DSPi?
The ADRE 408 DSPi is a multi-channel signal processing and data acquisition instrument used for real-time vibration analysis, machinery diagnostics, dynamic signal conditioning, and transient test data logging on rotating machinery.
How many dynamic channels does this specific 168679 model support?
This hardware configuration includes three 8-channel dynamic sampling cards (Slots 1 to 3), providing a total of 24 simultaneously sampled dynamic input channels.
Can the 408 DSPi record data without a computer connected?
Yes. The instrument features an internal 480GB solid-state drive (SSD) and front-panel controls that allow stand-alone data recording, event logging, and manual sampling without a continuously connected computer.
What function does the Digital Replay Card serve in Slot 5?
The Digital Replay Card allows users to reprocess and re-filter raw internal digital vibration data offline, enabling changes to trigger thresholds, filtering, order tracking, and waveform parameters without re-running the physical test.
How does the unit connect to client software like ADRE Sxp?
The instrument interfaces with client software via dual 1000/100Mb RJ45 Ethernet ports using standard TCP/IP protocol, supporting both DHCP and fixed IP configurations.
Reviews

168679-01-01-01-02-03-05-01-01-00-02-02

Stock &amp; lead time on request

Call
1 of 2

Bently Nevada 168679-01-01-01-02-03-05-01-01-00-02-02 ADRE 408 DSPi Dynamic Signal Processing Instrument

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 168679-01-01-01-02-03-05-01-01-00-02-02

  • Country of origin:United States

  • Product Type: Vibration Data Acquisition Systems

  • Payment: T/T, Western Union

  • Weight: 11500g

  • Dimensions: 560 x 460 x 240 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Bently Nevada 168679-01-01-01-02-03-05-01-01-00-02-02 is a multi-channel ADRE 408 DSPi Dynamic Signal Processing Instrument designed for real-time parallel signal processing, machinery condition monitoring, and advanced vibration data acquisition. The system functions as a digital recorder, spectrum analyzer, signal conditioner, oscilloscope, and filter platform, consolidating complex vibration analysis instrumentation into a single portable or rack-mountable enclosure. This specific build provides a 24-channel dynamic sampling architecture alongside speed, trigger, power supply, and digital replay capabilities for critical turbomachinery and rotating equipment diagnostic testing.

Engineered around a flexible client-server architecture, the 408 DSPi operates either as a standalone data recorder connected to corporate LAN/WAN networks or directly paired with a local host running ADRE Sxp software. The internal 480GB solid-state drive allows continuous high-speed data streaming and event logging independent of an active computer connection. This configuration populated across Slots 1 through 5 supports synchronous and asynchronous sampling across dynamic transducers, phase-reference Keyphasor inputs, and process transmitters without interrupting active data acquisition runs.

Features

  • Multi-Channel Dynamic Processing: Populated with three 8-channel dynamic sampling cards, delivering up to 24 simultaneous dynamic input channels with 24-bit A/D conversion.
  • Dedicated Speed & Trigger Management: Features one 3-channel speed input card supporting proximity, optical, magnetic, and laser tachometer inputs with built-in signal conditioning and buffered outputs.
  • Integrated Transducer Power: Includes a dedicated Transducer Power Supply Card capable of driving positive and negative bias 2-wire constant current sensors or 3-wire proximity probes.
  • Hardware Digital Replay Engine: Slot 5 equipped with a Digital Replay Card (without analog outputs) for offline reprocessing and signal re-conditioning without affecting original sampled dynamic data.
  • Standalone Storage & Networking: Contains an internal 480GB Solid State Drive (SSD) and dual 1000/100Mb Ethernet ports supporting DHCP or fixed IP addressing for network or local operation.
  • Rugged Enclosure & Power Kit: Built in an aluminum chassis with protective powder coating, complete with an external universal AC power supply (90–264 Vac) and hard shipping case for field deployment.
  • CE Compliance: Certified to European standards with CE approval marking.

Applications

  • Field vibration diagnostics and transient data collection during turbomachinery start-up and coast-down operations.
  • Multi-plane balancing analysis using Bently BALANCE software integration.
  • Structural dynamics testing and impact hammer excitation measurement.
  • Test stand validation and factory acceptance testing (FAT) for industrial turbines, compressors, pumps, and gearboxes.
  • Remote machinery condition monitoring across LAN/WAN infrastructure.

Ordering Information

Option Code Hardware / Configuration Selected
Model 168679 ADRE 408 DSPi Dynamic Signal Processing Instrument
Slot #1 (Option A) 01 - 8 Ch Dynamic Sampler Card
Slot #2 (Option B) 01 - 8 Ch Dynamic Sampler Card
Slot #3 (Option C) 01 - 8 Ch Dynamic Sampler Card
Slot #4 (Option D) 02 - 3 Ch Speed Input (KPH) / Trigger Card
Slot #5 (Option E) 03 - Transducer Power Supply Card
Option Slot #5 (Option E/Card) 05 / 01 - Digital Replay Card w/o Analog Output Card
Power Supply (Option F) 01 - 90/264 Vac 47/63Hz Power Supply (US, EU, BR Power Cords)
Carry Case (Option G) 01 - Hard Shipping Case
Metrology Cert (Option H) 00 - None
Rack Mount Kit (Option I) 00 - None
Solid State Drive (Option J) 02 - 480GB Solid State Drive
Approvals (Option K) 02 - CE

Technical Specifications

General

Parameter Specification
Manufacturer Bently Nevada (a Baker Hughes business)
Product Model ADRE 408 DSPi (Part Number 168679)
System Architecture Multi-channel Digital Signal Processing Instrument
Internal Data Storage 480GB Solid State Drive (SSD)
Real-Time Clock Accuracy Battery-backed RTC, 5 seconds/month
Chassis Construction Aluminum chassis with cast aluminum front/rear panels, textured black powder coating
Status Display / Controls Front panel LCD, LED status indicators, tactile switches

Dynamic Sampling (8-Channel Card x 3)

Parameter Specification
Dynamic Inputs 24 channels total (8 single-ended or 4 differential per card, 8 x 4-20mA)
A/D Conversion 24-bit resolution per channel
Single-Ended Input Impedance 742 kΩ
Differential Input Impedance 1.484 MΩ between Sig+ and Sig-
4-20 mA Input Impedance 511 Ω
Maximum Signal Input Range -25 to +25 V DC; 0.7 to 10 V AC
Asynchronous Sampling Rates 128 Hz to 128 kHz (Spans: 50 Hz to 50 kHz)
Synchronous Sampling Rates 16 to 2048 samples/revolution (Sync rate x RPM <= 32 kHz)
Direct Measurement Accuracy ±1% of Full Scale Range (DC to 50 kHz Hi Mode)
Bandpass Filter Options 2, 4, 6, 8 Pole Butterworth (HPF 1 Hz to 25.5 kHz, LPF 10 Hz to 50 kHz)
nX Amplitude & Phase Accuracy ±1% of Full Scale Range, ±3° of input (1 to 120,000 RPM)
Gap Voltage Range Fully programmable between -25 V DC and +25 V DC

Speed Input / Trigger (3-Channel Card)

Parameter Specification
Speed / Keyphasor Inputs 3 single-ended channels
Supported Transducers Proximity, magnetic, optical, laser, force hammer
Speed Range 1 to 120,000 RPM (0.0167 Hz to 2 kHz)
Speed Measurement Accuracy ±0.00915% of period input
Input Impedance 128.9 kΩ
Buffered Outputs 3 channels (Raw, Conditioned Analog, or TTL selectable); Short-circuit protected
Input Multiplier / Divider 3 stages per channel (8 digits pre-decimal, 12 digits post-decimal)

Transducer Power Supply

Parameter Specification
Power Capacity Up to 32 transducers simultaneously
Direct Connections 16 physical connections (8 x -24V DC, 8 x Constant Current)
Voltage Output Ratings -24 V DC (84.5 mA max), +24 V DC (29 mA max)
Constant Current Bias Positive (+3.36 mA) or Negative (-3.30 mA) selectable in blocks of 4
Protection Short-circuit protection and current regulation per output

Communication & Power Supply

Parameter Specification
Ethernet Ports Dual 1000/100Mb RJ45 ports
Network Protocols TCP/IP, DHCP or Fixed IP addressing
External Power Supply Input 90 to 264 Vac, 47 to 63 Hz auto-sensing
Power Supply Output +32 V DC ±5% @ 10 A Max; +5 V DC ±3% @ 600 mA Max

Physical & Environmental

Parameter Specification
408 DSPi Dimensions (L x W x H) 36.1 x 41.0 x 10.0 cm (14.25 x 16.0 x 3.8 in)
External Power Supply Dimensions 18.3 x 13.7 x 9.1 cm (7.2 x 5.4 x 3.6 in)
408 DSPi Weight 9.5 kg (21 lbs) fully populated with 32 channels
Power Supply Weight 1.3 kg (3 lbs)
Operating Temperature 0 degC to +50 degC (+32 degF to +122 degF)
Storage Temperature -30 degC to +80 degC (-22 degF to +176 degF)
Operating Humidity 0% to 95% non-condensing
Operational Vibration / Shock Vibration: 0.25G @ 5-100Hz; Shock: 10G @ 2ms

Connections / Interfaces

Connector / Interface Function
Front Panel SMA Ports Signal inputs for 8-channel dynamic sampling cards
Front Panel Speed BNC/SMA Ports Keyphasor, optical, and speed trigger input channels
Front Panel Keyphasor Terminal Optical transducer power output (+5 V DC) on Channel 3
Rear Panel Transducer Power 24 V DC and Constant Current power output terminal connections
Dual RJ45 Ports Independent primary LAN/WAN connection and local client interface
External DC Input Port High-reliability bayonet-locking connector for 32 V DC supply

Installation Guidelines

  1. Inspect the 408 DSPi instrument, external power supply, input cables, and hard shipping case for shipping damage before setup.
  2. Ensure proper physical placement on a benchtop or within a standard 19-inch rack, ensuring fan inlets remain unobstructed for cooling air flow.
  3. Connect the external power supply using the bayonet-locking DC connector and join the AC line to a 90–264 Vac power outlet.
  4. Connect dynamic signal inputs (proximity probes, accelerometers, or velocity sensors) to the SMA front panel connectors using appropriate adapter cables (SMA to BNC).
  5. Wire speed sensors or Keyphasor proximity drivers to the 3-channel Speed Input card.
  6. If powering sensors directly from the instrument, configure the Transducer Power Supply card switches for the required constant current (positive/negative bias) or -24 V DC settings prior to enabling transducer power.
  7. Connect an Ethernet cable from the primary RJ45 port on the instrument to a host PC or dedicated local network switch.

Configuration Guidelines

  1. Launch ADRE Quick Configuration or ADRE Sxp software on the client machine.
  2. Establish network communication using DHCP auto-discovery or by entering the fixed IP address assigned to the instrument port.
  3. Define the machine train layout, shaft rotational orientation, and sensor mounting angles in the software environment.
  4. Set channel-specific transducer parameters including scale factor (mV/mil, mV/g), coupling type (AC/DC), and full-scale range.
  5. Set up Keyphasor trigger thresholds, edge detection (rising/falling), and multiplier/divider ratios for order tracking.
  6. Download the generated configuration file to the 408 DSPi internal SSD storage.

Commissioning & Replacement Recommendations

  1. Verify sensor gap voltages and channel DC bias readings on the front display or software screen prior to machine start-up.
  2. Initiate a manual sample run from the front panel or client interface to confirm active dynamic sampling across all connected channels.
  3. Before replacing or re-configuring cards, stop active recording runs and back up stored database files from the 480GB internal SSD to an external drive or network host.
  4. When swapping processing cards, ensure power is removed from the unit before removing card retaining screws.

Compliance and Certifications

  • CE Compliance: Conforms to EMC Directive 2014/30/EU (EN 61000-6-2, EN 61000-6-4) and Low Voltage Directive 2014/35/EU.
  • RoHS: Complies with Directive 2011/65/EU.
  • FCC: Complies with Part 15 of FCC Rules for Class A digital devices.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 168679-01-01-01-02-03-05-01-01-00-02-02 ADRE 408 DSPi Dynamic Signal Processing Instrument

What is the primary function of the Bently Nevada ADRE 408 DSPi?

The ADRE 408 DSPi is a multi-channel signal processing and data acquisition instrument used for real-time vibration analysis, machinery diagnostics, dynamic signal conditioning, and transient test data logging on rotating machinery.

How many dynamic channels does this specific 168679 model support?

This hardware configuration includes three 8-channel dynamic sampling cards (Slots 1 to 3), providing a total of 24 simultaneously sampled dynamic input channels.

Can the 408 DSPi record data without a computer connected?

Yes. The instrument features an internal 480GB solid-state drive (SSD) and front-panel controls that allow stand-alone data recording, event logging, and manual sampling without a continuously connected computer.

What function does the Digital Replay Card serve in Slot 5?

The Digital Replay Card allows users to reprocess and re-filter raw internal digital vibration data offline, enabling changes to trigger thresholds, filtering, order tracking, and waveform parameters without re-running the physical test.

How does the unit connect to client software like ADRE Sxp?

The instrument interfaces with client software via dual 1000/100Mb RJ45 Ethernet ports using standard TCP/IP protocol, supporting both DHCP and fixed IP configurations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...