Bently Nevada

Bently Nevada 3300/16-11-01-02-03-02-00 PWA 86739-01 Dual Vibration Monitor

SKU 3300/16-11-01-02-03-02-00 86739-01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 3300/16-11-01-02-03-02-00 86739-01
  • Origin United States
  • Product Type: Dual Vibration Monitor
  • Payment: T/T, Western Union
  • Weight: 1.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3300/16-11-01-02-03-02-00 PWA 86739-01 Dual Vibration Monitor

Quantity

Product Description

Description

The Bently Nevada 3300/16-11-01-02-03-02-00 is a dual vibration monitor for the Bently Nevada 3300 machinery monitoring system. The unit uses the original PWA 86739-01 main circuit board.

The monitor continuously measures two independent radial vibration channels, identified as Channel A and Channel B. It also monitors proximity probe gap voltage for each channel.

This configuration has a vibration full-scale range of 0 to 100 um peak-to-peak. The transducer input option is designed for 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensors with a 200 mV/mil scale factor.

The unit includes a hermetically sealed alarm relay option and internal safety barriers. Alert and Danger functions provide independent machinery protection setpoints for the monitored channels.

Features

  • Dual-channel radial vibration monitoring

  • Independent Channel A and Channel B measurement

  • Probe gap voltage monitoring

  • 0 to 100 um peak-to-peak vibration range

  • Compatible with 3300 8 mm Proximitor Sensors

  • Compatible with 3300 XL 8 mm Proximitor Sensors

  • Compatible with 7200 5 mm and 8 mm Proximitor Sensors

  • 200 mV/mil transducer input scale factor

  • Hermetically sealed alarm relay configuration

  • Internal safety barrier configuration

  • Buffered transducer outputs

  • Alert and Danger alarm functions

  • First Out, bypass, self-test, and recorder-output functions

  • Original PWA 86739-01 main board

Applications

  • Radial shaft vibration monitoring

  • Shaft gap and position monitoring

  • Rotating machinery protection

  • Turbine and compressor vibration monitoring

  • Machinery condition monitoring using proximity probe systems

  • Replacement of existing 3300/16 monitors with matching configuration

Ordering Information

Option Configuration
Model 3300/16 Dual Vibration Monitor
A: Full-scale Range 11 - 0 to 100 um peak-to-peak
B: Transducer Input 01 - 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensor
Transducer Scale Factor 200 mV/mil
C: Alarm Relay 02 - Hermetically sealed
D: Agency Approval 03 - Exact catalog code retained; meaning not defined in supplied Rev. P manual
E: Safety Barrier 02 - Internal
F: Trip Multiply 00 - None

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model 3300/16-11-01-02-03-02-00
Product Type Dual Vibration Monitor
System 3300
Main PWA 86739-01
PWA Version Original
Number of Channels 2
Measurement Radial vibration and probe gap
Vibration Full-scale Range 0 to 100 um peak-to-peak
Transducer Input 3300 8 mm, 3300 XL 8 mm, 7200 5 mm and 8 mm Proximitor Sensors
Transducer Scale Factor 200 mV/mil
Alarm Relay Hermetically sealed
Safety Barrier Internal
Trip Multiply None
Recorder Outputs 0 to -10 Vdc, +1 to +5 Vdc, or +4 to +20 mA
Buffered Outputs Front-panel coaxial connectors and rear Signal Input Relay Module

Monitor Functions

Function Description
Radial Vibration Continuous measurement of shaft dynamic motion for Channels A and B
Probe Gap Displays negative DC voltage proportional to probe-to-target gap
Alert Alarm First-level vibration alarm
Danger Alarm Second-level vibration alarm
First Out Identifies the first channel entering an alarm state when enabled
Channel Bypass Removes a selected channel from active monitoring
Danger Bypass Inhibits Danger relay drive during maintenance
Buffered Output Provides transducer signals for external equipment
Recorder Output Provides output proportional to measured vibration
Self-Test Power-up, cyclic, and user-invoked diagnostic testing

PWA 86739-01 Configuration

The 86739-01 is the original version of the 3300/16 main PWA.

Its programmable options are configured through jumpers on the main circuit board. These include First Out, alarm latching, Danger voting, vibration alarm delay, Gap Alarm, recorder clamping, corner frequency, recorder output, gap range, vibration range, transducer input, and Trip Multiply.

Installation & Commissioning

  • Confirm the complete catalog number before replacing the installed monitor.

  • Verify the installed board is PWA 86739-01 before changing jumper settings.

  • Confirm the Proximitor Sensor type and 200 mV/mil scale factor.

  • Record Alert, Danger, gap, recorder, and bypass settings before removal.

  • Power down the rack or inhibit rack alarms before removing the monitor.

  • Verify internal safety barrier wiring before reconnecting field circuits.

  • Check both vibration channels and gap readings after installation.

  • Confirm Alert and Danger functions before returning the system to service.

Replacement Notes

  • PWA 86739-01 uses different jumper locations from later 135305-01 and 140720-01 boards.

  • Do not copy jumper positions from later PWA revisions.

  • Match the full-scale range, transducer input, relay type, safety barrier, and Trip Multiply configuration.

  • Preserve the exact catalog number when sourcing a replacement.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the Bently Nevada 3300/16-11-01-02-03-02-00 used for?
The Bently Nevada 3300/16-11-01-02-03-02-00 monitors two independent radial vibration channels and probe gap in a 3300 machinery monitoring system.
What vibration range does the 3300/16-11-01-02-03-02-00 use?
The Bently Nevada 3300/16-11-01-02-03-02-00 uses full-scale range option 11, corresponding to 0 to 100 um peak-to-peak vibration.
Which Proximitor Sensors are compatible with this 3300/16 configuration?
The Bently Nevada 3300/16-11-01-02-03-02-00 uses transducer option 01 for 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensors at 200 mV/mil.
What is PWA 86739-01 in the Bently Nevada 3300/16?
The Bently Nevada 3300/16 with PWA 86739-01 uses the original main-board version. Its programmable jumper locations differ from later 135305-01 and 140720-01 PWA revisions.
Does this 3300/16 monitor include internal safety barriers?
The Bently Nevada 3300/16-11-01-02-03-02-00 includes option E02, which identifies the internal safety barrier configuration in the supplied Bently Nevada manual.
What should be checked before replacing a PWA 86739-01 monitor?
The Bently Nevada 3300/16 replacement should match the full catalog number, PWA revision, transducer input, vibration range, relay configuration, barriers, and existing jumper-programmed options.
Reviews

3300/16-11-01-02-03-02-00 86739-01

Stock & lead time on request

Call
1 of 5

Bently Nevada 3300/16-11-01-02-03-02-00 PWA 86739-01 Dual Vibration Monitor

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3300/16-11-01-02-03-02-00 86739-01

  • Country of origin:United States

  • Product Type: Dual Vibration Monitor

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Bently Nevada 3300/16-11-01-02-03-02-00 is a dual vibration monitor for the Bently Nevada 3300 machinery monitoring system. The unit uses the original PWA 86739-01 main circuit board.

The monitor continuously measures two independent radial vibration channels, identified as Channel A and Channel B. It also monitors proximity probe gap voltage for each channel.

This configuration has a vibration full-scale range of 0 to 100 um peak-to-peak. The transducer input option is designed for 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensors with a 200 mV/mil scale factor.

The unit includes a hermetically sealed alarm relay option and internal safety barriers. Alert and Danger functions provide independent machinery protection setpoints for the monitored channels.

Features

  • Dual-channel radial vibration monitoring

  • Independent Channel A and Channel B measurement

  • Probe gap voltage monitoring

  • 0 to 100 um peak-to-peak vibration range

  • Compatible with 3300 8 mm Proximitor Sensors

  • Compatible with 3300 XL 8 mm Proximitor Sensors

  • Compatible with 7200 5 mm and 8 mm Proximitor Sensors

  • 200 mV/mil transducer input scale factor

  • Hermetically sealed alarm relay configuration

  • Internal safety barrier configuration

  • Buffered transducer outputs

  • Alert and Danger alarm functions

  • First Out, bypass, self-test, and recorder-output functions

  • Original PWA 86739-01 main board

Applications

  • Radial shaft vibration monitoring

  • Shaft gap and position monitoring

  • Rotating machinery protection

  • Turbine and compressor vibration monitoring

  • Machinery condition monitoring using proximity probe systems

  • Replacement of existing 3300/16 monitors with matching configuration

Ordering Information

Option Configuration
Model 3300/16 Dual Vibration Monitor
A: Full-scale Range 11 - 0 to 100 um peak-to-peak
B: Transducer Input 01 - 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensor
Transducer Scale Factor 200 mV/mil
C: Alarm Relay 02 - Hermetically sealed
D: Agency Approval 03 - Exact catalog code retained; meaning not defined in supplied Rev. P manual
E: Safety Barrier 02 - Internal
F: Trip Multiply 00 - None

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Model 3300/16-11-01-02-03-02-00
Product Type Dual Vibration Monitor
System 3300
Main PWA 86739-01
PWA Version Original
Number of Channels 2
Measurement Radial vibration and probe gap
Vibration Full-scale Range 0 to 100 um peak-to-peak
Transducer Input 3300 8 mm, 3300 XL 8 mm, 7200 5 mm and 8 mm Proximitor Sensors
Transducer Scale Factor 200 mV/mil
Alarm Relay Hermetically sealed
Safety Barrier Internal
Trip Multiply None
Recorder Outputs 0 to -10 Vdc, +1 to +5 Vdc, or +4 to +20 mA
Buffered Outputs Front-panel coaxial connectors and rear Signal Input Relay Module

Monitor Functions

Function Description
Radial Vibration Continuous measurement of shaft dynamic motion for Channels A and B
Probe Gap Displays negative DC voltage proportional to probe-to-target gap
Alert Alarm First-level vibration alarm
Danger Alarm Second-level vibration alarm
First Out Identifies the first channel entering an alarm state when enabled
Channel Bypass Removes a selected channel from active monitoring
Danger Bypass Inhibits Danger relay drive during maintenance
Buffered Output Provides transducer signals for external equipment
Recorder Output Provides output proportional to measured vibration
Self-Test Power-up, cyclic, and user-invoked diagnostic testing

PWA 86739-01 Configuration

The 86739-01 is the original version of the 3300/16 main PWA.

Its programmable options are configured through jumpers on the main circuit board. These include First Out, alarm latching, Danger voting, vibration alarm delay, Gap Alarm, recorder clamping, corner frequency, recorder output, gap range, vibration range, transducer input, and Trip Multiply.

Installation & Commissioning

  • Confirm the complete catalog number before replacing the installed monitor.

  • Verify the installed board is PWA 86739-01 before changing jumper settings.

  • Confirm the Proximitor Sensor type and 200 mV/mil scale factor.

  • Record Alert, Danger, gap, recorder, and bypass settings before removal.

  • Power down the rack or inhibit rack alarms before removing the monitor.

  • Verify internal safety barrier wiring before reconnecting field circuits.

  • Check both vibration channels and gap readings after installation.

  • Confirm Alert and Danger functions before returning the system to service.

Replacement Notes

  • PWA 86739-01 uses different jumper locations from later 135305-01 and 140720-01 boards.

  • Do not copy jumper positions from later PWA revisions.

  • Match the full-scale range, transducer input, relay type, safety barrier, and Trip Multiply configuration.

  • Preserve the exact catalog number when sourcing a replacement.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3300/16-11-01-02-03-02-00 PWA 86739-01 Dual Vibration Monitor

What is the Bently Nevada 3300/16-11-01-02-03-02-00 used for?

The Bently Nevada 3300/16-11-01-02-03-02-00 monitors two independent radial vibration channels and probe gap in a 3300 machinery monitoring system.

What vibration range does the 3300/16-11-01-02-03-02-00 use?

The Bently Nevada 3300/16-11-01-02-03-02-00 uses full-scale range option 11, corresponding to 0 to 100 um peak-to-peak vibration.

Which Proximitor Sensors are compatible with this 3300/16 configuration?

The Bently Nevada 3300/16-11-01-02-03-02-00 uses transducer option 01 for 3300 8 mm, 3300 XL 8 mm, or 7200 5 mm and 8 mm Proximitor Sensors at 200 mV/mil.

What is PWA 86739-01 in the Bently Nevada 3300/16?

The Bently Nevada 3300/16 with PWA 86739-01 uses the original main-board version. Its programmable jumper locations differ from later 135305-01 and 140720-01 PWA revisions.

Does this 3300/16 monitor include internal safety barriers?

The Bently Nevada 3300/16-11-01-02-03-02-00 includes option E02, which identifies the internal safety barrier configuration in the supplied Bently Nevada manual.

What should be checked before replacing a PWA 86739-01 monitor?

The Bently Nevada 3300/16 replacement should match the full catalog number, PWA revision, transducer input, vibration range, relay configuration, barriers, and existing jumper-programmed options.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...