Description
An unthreaded length of 0 mm (Option 000) and an overall case length of 50 mm (Option 050) define the metric M16 x 1.5 unarmored body configuration of this 330709-000-050-10-02-05 3300 XL 11 mm proximity probe. This metric non-contact transducer operates without stainless steel armor and is equipped with a 1.0 m (3.3 ft) integrated coaxial cable (Option 10) terminated in a standard miniature coaxial ClickLoc connector (Option 02) without a connector protector.
With an Option 05 configuration, this probe includes multiple international agency certifications for hazardous areas, allowing for direct installation in intrinsically safe and non-incendive environments. Designed to work in coordination with a 330730 extension cable and a 330780 Proximitor sensor, this transducer system offers a 4.0 mm (160 mils) linear range, which is approximately double that of the standard 8 mm transducer systems, making it highly effective for axial position, ramp differential expansion, and reciprocating compressor rod measurements.
Features
- Metric M16 x 1.5 threaded case with 0 mm unthreaded length and 50 mm total case length.
- Integrated 1.0 m (3.3 ft) triaxial FEP insulated standard cable without protective armor.
- Gold-plated brass miniature coaxial ClickLoc connector for reliable signal transmission.
- Generates a scale factor of 3.94 V/mm (100 mV/mil) over a 4.0 mm (160 mils) linear range.
- Multiple agency approvals (Option 05) including ATEX, IECEx, and CSA certifications for hazardous areas.
Applications
- Axial thrust position monitoring on steam and gas turbines.
- Ramp differential expansion measurements on power generation turbines.
- Reciprocating compressor rod position and rod drop monitoring.
- Shaft vibration and Keyphasor phase reference sensing on large rotating machinery.
Ordering Information
| Option / Segment |
Code on This SKU |
Description / Meaning |
| Base Model |
330709 |
3300 XL 11 mm Proximity Probe, M16 x 1.5 thread, without armor |
| A: Unthreaded Length Option |
000 |
0 mm unthreaded length (fully threaded case) |
| B: Overall Case Length Option |
050 |
50 mm overall case length |
| C: Total Length Option |
10 |
1.0 meter (3.3 feet) total length |
| D: Connector and Cable-Type Option |
02 |
Miniature coaxial ClickLoc connector, standard cable |
| E: Agency Approval Option |
05 |
Multiple Approvals (CSA, ATEX, IECEx) |
Technical Specifications
| Parameter |
Specification |
| Manufacturer |
Bently Nevada |
| Model / Part Number |
330709-000-050-10-02-05 |
| System Type |
3300 XL 11 mm Proximity Transducer System |
| Probe Diameter |
11 mm |
| Case Thread |
M16 x 1.5 metric |
| Case Material |
AISI 304 stainless steel (SST) |
| Tip Material |
Polyphenylene sulfide (PPS) |
| Cable Type |
75 ohm triaxial, FEP insulated standard cable (unarmored) |
| Connector Material |
Gold-plated brass miniature coaxial ClickLoc |
| Linear Range |
4.0 mm (160 mils), from 0.5 to 4.5 mm (20 to 180 mils) |
| Recommended Gap |
2.5 mm (100 mils) |
| Incremental Scale Factor (ISF) |
3.94 V/mm (100 mV/mil) +/- 10% |
| Probe DC Resistance |
5.9 ohm +/- 0.5 ohm |
| Maximum Torque Rating |
63.3 N-m (560 in-lb) |
| Recommended Torque |
21.1 N-m (187 in-lb) |
| Tensile Strength |
330 N (75 lb) probe case to lead; 270 N (60 lb) lead to extension cable |
| Operating and Storage Temperature |
-52 degC to +177 degC (-62 degF to +351 degF) |
| Pressure Sealing |
Viton O-ring differential pressure seal |
| Environmental Protection |
100% condensing, non-submersible when connectors are protected |
Installation Guidelines
-
Gap Adjustment: Adjust the sensor gap to 2.5 mm (100 mils) from the target surface, corresponding to a nominal output voltage of -10 Vdc.
-
Minimum Bend Radius: Maintain a minimum coaxial cable bend radius of 25.4 mm (1.0 in) during installation to protect signal transmission.
-
Torque Limit: Tighten the M16 x 1.5 probe case to a recommended 21.1 N-m (187 in-lb). Do not exceed the maximum rated torque of 63.3 N-m (560 in-lb) to prevent damage.
-
Connector Connection: Screw ClickLoc connectors together hand-tight. Do not use mechanics tools that could over-torque the brass housing.
Compliance and Certifications
-
EMC: European Community Directive 2014/30/EU, EN 61000-6-2, EN 61000-6-4
-
RoHS: European Community Directive 2011/65/EU
-
China RoHS: EFUP designation of 15 years per SJ/T 11364-2024
-
Functional Safety: SIL 2 capable (HFT = 0), SIL 3 capable (HFT = 1)
-
Hazardous Area Approvals: Intrinsically Safe (ia) and Non-incendive (nA, ec) per Class I, Zone 0, Zone 2, Div 1, and Div 2 standards (CSA, ATEX, IECEx)