Description

The BECKHOFF IP1000-B730 is a Modbus RTU/ASCII Fieldbus Box designed to act as a decentralized interface in demanding industrial automation environments. This compact module enables reliable communication and integration of field devices into Modbus serial networks, ensuring steady operation and high environmental durability. Built to survive challenging field conditions, it features a fully sealed design that facilitates direct machine mounting without the need for an additional protective enclosure.

By shifting the communication interface directly into the field, the BECKHOFF IP1000-B730 minimizes wiring overhead and simplifies distributed machine architectures. It offers configuration options via onboard address selection switches or specialized configuration software, providing flexibility during commissioning and system integration.

Features

  • Protocol support for Modbus RTU and Modbus ASCII standards.
  • Flexible address configuration using integrated physical rotary switches or the KS2000 software tool.
  • Wide range of supported serial data transfer rates from 150 to 38,400 baud.
  • Standardized M12 fieldbus interface with secure B-coding.
  • M8 power supply connection system featuring feed and downstream daisy-chain capability.
  • Electrical isolation between the control voltage and the fieldbus interface for enhanced noise immunity.
  • High protection rating of IP65/66/67, permitting direct mounting in wet, dusty, or harsh industrial environments.

Applications

  • Decentralized machine control and distributed I/O network architectures.
  • Field-level sensor and actuator communication using Modbus serial communication.
  • In-the-field installations requiring robust environmental protection without control cabinets.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1000-B730
Product Type Fieldbus Box

Communication & Configuration

Parameter Specification
Protocol Modbus RTU / Modbus ASCII
Data Transfer Rates 150, 300, 600, 1200, 2400, 4800, 9600, 19,200, 38,400 baud
Configuration Method Address selection switch or KS2000 software
Bus Interface 1 x M12 socket, 5-pin, B-coded

Electrical Data

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + sensor current consumption (max. 0.5 A)
Electrical Isolation Control voltage to fieldbus: Yes

Mechanical & Environmental

Parameter Specification
Weight Approx. 210 g
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Ingress Protection IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration & Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity & Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals & Markings CE, UL

Installation Guidelines

  1. Verify that the system power supply is completely de-energized before beginning installation of the BECKHOFF IP1000-B730.
  2. Mount the Fieldbus Box securely to a flat mounting surface using appropriate fastening screws to ensure mechanical stability.
  3. Set the required Modbus node address using the integrated address selection switches or prepare the unit for KS2000 software configuration.
  4. Connect the 24 V DC control voltage supply to the 4-pin M8 male feed socket, paying close attention to correct pin alignment.
  5. Attach the Modbus RTU/ASCII network cable to the 5-pin B-coded M12 socket connector.
  6. Seal any unused M8 or M12 connector ports with matching protective caps to preserve the IP65/IP66/IP67 environmental protection rating.
  7. Re-energize the system and verify communication and device operation using the diagnostic indicators.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP1000-B730?
The BECKHOFF IP1000-B730 is a Modbus RTU/ASCII Fieldbus Box designed to act as a decentralized interface that connects field-level equipment directly to a Modbus serial network without requiring an electrical cabinet.
What baud rates are supported by the BECKHOFF IP1000-B730?
The BECKHOFF IP1000-B730 supports multiple configurable data transfer rates, including 150, 300, 600, 1200, 2400, 4800, 9600, 19200, and 38400 baud.
How is the BECKHOFF IP1000-B730 configured?
The BECKHOFF IP1000-B730 can be configured by using the onboard physical address selection switches or via the BECKHOFF KS2000 software interface.
What physical connections does the BECKHOFF IP1000-B730 use?
The BECKHOFF IP1000-B730 utilizes a 5-pin B-coded M12 socket for the Modbus fieldbus connection, and M8 connectors for power distribution (one 4-pin male feed and one 4-pin female downstream connection).
Reviews

IP1000-B730

Stock & lead time on request

Call
1 of 1

BECKHOFF IP1000-B730 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP1000-B730

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 210g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP1000-B730 is a Modbus RTU/ASCII Fieldbus Box designed to act as a decentralized interface in demanding industrial automation environments. This compact module enables reliable communication and integration of field devices into Modbus serial networks, ensuring steady operation and high environmental durability. Built to survive challenging field conditions, it features a fully sealed design that facilitates direct machine mounting without the need for an additional protective enclosure.

By shifting the communication interface directly into the field, the BECKHOFF IP1000-B730 minimizes wiring overhead and simplifies distributed machine architectures. It offers configuration options via onboard address selection switches or specialized configuration software, providing flexibility during commissioning and system integration.

Features

  • Protocol support for Modbus RTU and Modbus ASCII standards.
  • Flexible address configuration using integrated physical rotary switches or the KS2000 software tool.
  • Wide range of supported serial data transfer rates from 150 to 38,400 baud.
  • Standardized M12 fieldbus interface with secure B-coding.
  • M8 power supply connection system featuring feed and downstream daisy-chain capability.
  • Electrical isolation between the control voltage and the fieldbus interface for enhanced noise immunity.
  • High protection rating of IP65/66/67, permitting direct mounting in wet, dusty, or harsh industrial environments.

Applications

  • Decentralized machine control and distributed I/O network architectures.
  • Field-level sensor and actuator communication using Modbus serial communication.
  • In-the-field installations requiring robust environmental protection without control cabinets.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1000-B730
Product Type Fieldbus Box

Communication & Configuration

Parameter Specification
Protocol Modbus RTU / Modbus ASCII
Data Transfer Rates 150, 300, 600, 1200, 2400, 4800, 9600, 19,200, 38,400 baud
Configuration Method Address selection switch or KS2000 software
Bus Interface 1 x M12 socket, 5-pin, B-coded

Electrical Data

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + sensor current consumption (max. 0.5 A)
Electrical Isolation Control voltage to fieldbus: Yes

Mechanical & Environmental

Parameter Specification
Weight Approx. 210 g
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Ingress Protection IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration & Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity & Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals & Markings CE, UL

Installation Guidelines

  1. Verify that the system power supply is completely de-energized before beginning installation of the BECKHOFF IP1000-B730.
  2. Mount the Fieldbus Box securely to a flat mounting surface using appropriate fastening screws to ensure mechanical stability.
  3. Set the required Modbus node address using the integrated address selection switches or prepare the unit for KS2000 software configuration.
  4. Connect the 24 V DC control voltage supply to the 4-pin M8 male feed socket, paying close attention to correct pin alignment.
  5. Attach the Modbus RTU/ASCII network cable to the 5-pin B-coded M12 socket connector.
  6. Seal any unused M8 or M12 connector ports with matching protective caps to preserve the IP65/IP66/IP67 environmental protection rating.
  7. Re-energize the system and verify communication and device operation using the diagnostic indicators.
Loading product navigation…

What is the primary function of the BECKHOFF IP1000-B730?

The BECKHOFF IP1000-B730 is a Modbus RTU/ASCII Fieldbus Box designed to act as a decentralized interface that connects field-level equipment directly to a Modbus serial network without requiring an electrical cabinet.

What baud rates are supported by the BECKHOFF IP1000-B730?

The BECKHOFF IP1000-B730 supports multiple configurable data transfer rates, including 150, 300, 600, 1200, 2400, 4800, 9600, 19200, and 38400 baud.

How is the BECKHOFF IP1000-B730 configured?

The BECKHOFF IP1000-B730 can be configured by using the onboard physical address selection switches or via the BECKHOFF KS2000 software interface.

What physical connections does the BECKHOFF IP1000-B730 use?

The BECKHOFF IP1000-B730 utilizes a 5-pin B-coded M12 socket for the Modbus fieldbus connection, and M8 connectors for power distribution (one 4-pin male feed and one 4-pin female downstream connection).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...