BECKHOFF

BECKHOFF IP1002-B310 Fieldbus Box

SKU IP1002-B310

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP1002-B310
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 0.35 kg
  • Dimensions: 3.0 x 17.5 x 2.65 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF IP1002-B310 is a decentralized Fieldbus Box featuring an integrated PROFIBUS interface and 8 digital inputs. Designed for machine-level installation without a control cabinet, this IP65/66/67-rated module connects binary control signals directly to a PROFIBUS DP network in harsh industrial environments.

Equipped with M12 connectors for signal acquisition and M8 connectors for power distribution, the IP1002-B310 integrates into automated systems requiring distributed signal collection. Configuration is supported via the KS2000 software or the controller utilizing DP-V1 extensions, with automatic baud rate detection up to 12 Mbaud.

Features

  • 8-channel digital input configuration conforming to EN 61131-2, type 2
  • Integrated PROFIBUS DP interface with automatic baud rate detection up to 12 Mbaud
  • M12 connection technology for secure sensor wiring
  • M8 connectors for 24 V DC power feed and downstream connection
  • Rugged PA6 polyamide housing with IP65/66/67 protection rating for cabinet-free installation
  • DP-V1 extension support for flexible parameterization and diagnostics

Applications

  • Decentralized machine building and factory automation
  • Conveyor and material handling systems
  • Assembly lines and packaging machinery
  • Industrial environments requiring cabinet-free I/O distribution

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP1002-B310
Product Type Fieldbus Box
Housing Type Standard housing
Material PA6 (polyamide)
Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Installation Position Variable
Mounting 2 fixing holes 3.5 mm diameter for M3
Country of Origin Germany

Digital Inputs

Parameter Specification
Number of Inputs 8
Input Connections M12, screw type
Nominal Input Voltage 24 V DC (-15 %/+20 %)
Input Filter 3.0 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 2)
Input Current typ. 6 mA (EN 61131-2, type 2)
Sensor Supply from control voltage, max. 0.5 A, short-circuit proof in total
Bit Width in Process Image 8 inputs

Communication and PROFIBUS Interface

Parameter Specification
Bus System PROFIBUS DP
Bus Interface 1 x M12 socket, 5-pin, B-coded
Data Transfer Rates Automatic detection up to 12 Mbaud
Configuration Via KS2000 or controller, DP-V1 extensions supported

Electrical

Parameter Specification
Control Voltage Supply 24 V DC (-15 %/+20 %)
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
Box Supply Current 85 mA + current consumption of sensors, max. 0.5 A
Electrical Isolation Control voltage/fieldbus: no; control voltage/inputs: according to I/O type

Environmental and Approvals

Parameter Specification
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Approvals / Markings CE, UL

Connections / Interfaces

Interface / Terminal Function
M12 Socket (5-pin, B-coded) PROFIBUS DP bus interface
M12 Sockets (Screw type) 8 x Digital inputs (channels 1 to 8)
M8 Male Socket (4-pin) Control voltage power feed (24 V DC)
M8 Female Socket (4-pin) Downstream control voltage power connection

Installation Guidelines

  1. Ensure the system is completely de-energized before mounting or wiring the BECKHOFF IP1002-B310.
  2. Secure the unit directly onto a flat mounting surface using two M3 screws through the 3.5 mm fixing holes.
  3. Connect the 24 V DC control voltage supply to the M8 male feed socket using a compatible 4-pin cable.
  4. Connect PROFIBUS communication cables to the B-coded M12 bus socket.
  5. Attach binary sensors to the M12 input channels, ensuring signal levels conform to EN 61131-2, type 2 requirements.
  6. Verify all M12 and M8 screw connections are securely fastened to maintain IP65/66/67 environmental protection.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the BECKHOFF IP1002-B310?
The BECKHOFF IP1002-B310 is a decentralized Fieldbus Box equipped with an integrated PROFIBUS interface and 8 digital inputs, engineered for cabinet-free machine-level installations.
What communication protocol does the IP1002-B310 support?
The BECKHOFF IP1002-B310 supports the PROFIBUS DP communication protocol with automatic baud rate detection up to 12 Mbaud and DP-V1 extension capabilities.
How many digital inputs does the BECKHOFF IP1002-B310 feature?
The BECKHOFF IP1002-B310 features 8 digital input channels configured with M12 screw-type connections conforming to EN 61131-2, type 2 specifications.
What is the enclosure protection rating of the IP1002-B310?
The BECKHOFF IP1002-B310 features an IP65, IP66, and IP67 protection rating, ensuring reliable operation in harsh industrial environments without requiring a control cabinet.
Reviews

IP1002-B310

Stock & lead time on request

Call
1 of 1

BECKHOFF IP1002-B310 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP1002-B310

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 3.0 x 17.5 x 2.65 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP1002-B310 is a decentralized Fieldbus Box featuring an integrated PROFIBUS interface and 8 digital inputs. Designed for machine-level installation without a control cabinet, this IP65/66/67-rated module connects binary control signals directly to a PROFIBUS DP network in harsh industrial environments.

Equipped with M12 connectors for signal acquisition and M8 connectors for power distribution, the IP1002-B310 integrates into automated systems requiring distributed signal collection. Configuration is supported via the KS2000 software or the controller utilizing DP-V1 extensions, with automatic baud rate detection up to 12 Mbaud.

Features

  • 8-channel digital input configuration conforming to EN 61131-2, type 2
  • Integrated PROFIBUS DP interface with automatic baud rate detection up to 12 Mbaud
  • M12 connection technology for secure sensor wiring
  • M8 connectors for 24 V DC power feed and downstream connection
  • Rugged PA6 polyamide housing with IP65/66/67 protection rating for cabinet-free installation
  • DP-V1 extension support for flexible parameterization and diagnostics

Applications

  • Decentralized machine building and factory automation
  • Conveyor and material handling systems
  • Assembly lines and packaging machinery
  • Industrial environments requiring cabinet-free I/O distribution

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP1002-B310
Product Type Fieldbus Box
Housing Type Standard housing
Material PA6 (polyamide)
Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Installation Position Variable
Mounting 2 fixing holes 3.5 mm diameter for M3
Country of Origin Germany

Digital Inputs

Parameter Specification
Number of Inputs 8
Input Connections M12, screw type
Nominal Input Voltage 24 V DC (-15 %/+20 %)
Input Filter 3.0 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 2)
Input Current typ. 6 mA (EN 61131-2, type 2)
Sensor Supply from control voltage, max. 0.5 A, short-circuit proof in total
Bit Width in Process Image 8 inputs

Communication and PROFIBUS Interface

Parameter Specification
Bus System PROFIBUS DP
Bus Interface 1 x M12 socket, 5-pin, B-coded
Data Transfer Rates Automatic detection up to 12 Mbaud
Configuration Via KS2000 or controller, DP-V1 extensions supported

Electrical

Parameter Specification
Control Voltage Supply 24 V DC (-15 %/+20 %)
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
Box Supply Current 85 mA + current consumption of sensors, max. 0.5 A
Electrical Isolation Control voltage/fieldbus: no; control voltage/inputs: according to I/O type

Environmental and Approvals

Parameter Specification
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP65 / IP66 / IP67 (conforms to EN 60529)
Approvals / Markings CE, UL

Connections / Interfaces

Interface / Terminal Function
M12 Socket (5-pin, B-coded) PROFIBUS DP bus interface
M12 Sockets (Screw type) 8 x Digital inputs (channels 1 to 8)
M8 Male Socket (4-pin) Control voltage power feed (24 V DC)
M8 Female Socket (4-pin) Downstream control voltage power connection

Installation Guidelines

  1. Ensure the system is completely de-energized before mounting or wiring the BECKHOFF IP1002-B310.
  2. Secure the unit directly onto a flat mounting surface using two M3 screws through the 3.5 mm fixing holes.
  3. Connect the 24 V DC control voltage supply to the M8 male feed socket using a compatible 4-pin cable.
  4. Connect PROFIBUS communication cables to the B-coded M12 bus socket.
  5. Attach binary sensors to the M12 input channels, ensuring signal levels conform to EN 61131-2, type 2 requirements.
  6. Verify all M12 and M8 screw connections are securely fastened to maintain IP65/66/67 environmental protection.
Loading product navigation…

What is the BECKHOFF IP1002-B310?

The BECKHOFF IP1002-B310 is a decentralized Fieldbus Box equipped with an integrated PROFIBUS interface and 8 digital inputs, engineered for cabinet-free machine-level installations.

What communication protocol does the IP1002-B310 support?

The BECKHOFF IP1002-B310 supports the PROFIBUS DP communication protocol with automatic baud rate detection up to 12 Mbaud and DP-V1 extension capabilities.

How many digital inputs does the BECKHOFF IP1002-B310 feature?

The BECKHOFF IP1002-B310 features 8 digital input channels configured with M12 screw-type connections conforming to EN 61131-2, type 2 specifications.

What is the enclosure protection rating of the IP1002-B310?

The BECKHOFF IP1002-B310 features an IP65, IP66, and IP67 protection rating, ensuring reliable operation in harsh industrial environments without requiring a control cabinet.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors in different ways. This comparison covers torque quality, speed range, reversal, braking, electrical noise, thermal behavior, feedback, and retrofit...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controllable AC from a DC bus through semiconductor switching and filtering. This guide explains H-bridges, PWM, harmonics, motor loads, protection, thermal limits,...

Robot Force Control: From Contact Detection to Stable Process

Force control lets a robot adapt to contact instead of following position alone. This guide compares sensing approaches, control modes, process limits, safety boundaries, commissioning tests, and...

When Sensor-Level Logic Helps—and When It Hides Risk

Configurable sensors can perform window, latch, delay, and Boolean decisions before data reaches a PLC. The benefit is faster local behavior; the risk is hidden logic, weak diagnostics, and...

Connecting GX Simulator to Factory I/O Through OPC

A stable Mitsubishi virtual commissioning setup requires more than matching addresses. This guide explains the GX Simulator–OPC–Factory I/O data path, namespace design, scan timing, validation, and...