BECKHOFF

Beckhoff IP1010-B518 Fieldbus Box Digital Input Module

SKU IP1010-B518

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: IP1010-B518

  • Country of origin:Germany

  • Product Type: Digital Input Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Configured for direct machine mounting without a control cabinet, the Beckhoff IP1010-B518 serves as a robust CANopen digital input module within the modular Fieldbus Box system. This dust-proof and water-resistant unit acquires binary control signals from the physical process level and transmits them to the higher-level controller via an integrated CANopen fieldbus interface. Featuring 8 distinct digital input channels with a fast 0.2 ms input filter, it is optimized for high-speed signal processing and automated system diagnostics. The connection design utilizes space-saving Ø8 mm (M8) snap-in circular connectors, while physical network wiring is streamlined through an integrated T-connector for straightforward bus looping.

Features

  • 8-channel digital input configuration for 24 V DC sensor signals.
  • Rapid signal acquisition utilizing a integrated 0.2 ms input filter.
  • Seamless system integration via the standard CANopen protocol.
  • Integrated T-connector for direct, loop-through bus cabling without external splitters.
  • Rugged IP67-rated enclosure suitable for harsh industrial environments.
  • M8 (Ø8 mm) snap-in connections for swift, tool-free sensor wiring.

Applications

  • Decentralized manufacturing automation systems.
  • Conveyor and material handling lines.
  • Automotive assembly and robotic work cells.
  • Packaging and food processing machinery requiring washdown-capable IP67 equipment.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model IP1010-B518
Product Series Fieldbus Box
Fieldbus Protocol CANopen
Number of Channels 8 digital inputs
Nominal Voltage 24 V DC (-15% / +20%)
Input Filter Time 0.2 ms
Sensor Connection 8 x M8 (Ø8 mm) snap-in sockets, 3-pin
Bus Connection Integrated T-connector
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP67
Shipping Weight 2.0 kg

Connections and Interfaces

M8 Pin Number Signal Assignment
1 +24 V DC Sensor Supply
3 0 V (GND)
4 Input Signal (DI)

Installation Guidelines

  • Mount the module directly to the machine frame or aluminum profiles using the integrated mounting holes.
  • To maintain the IP67 protection rating, ensure all unused M8 sensor sockets are fitted with protective screw/snap-in caps.
  • Verify that the CANopen network termination resistors are correctly positioned at the physically first and last nodes of the segment.
  • Avoid routing high-voltage power cables in close parallel proximity to the fieldbus communication lines.

Compliance and Certifications

  • CE
  • UL
  • RoHS

FAQ

What fieldbus protocol does the Beckhoff IP1010-B518 support?

The Beckhoff IP1010-B518 communicates using the standard CANopen fieldbus protocol.

What is the physical connection standard for the sensors?

The module features 8 sensor inputs terminated with 3-pin M8 (Ø8 mm) snap-in circular connectors.

What is the input filter speed of this module?

The IP1010-B518 is equipped with a rapid 0.2 ms input filter response time.

How is the CANopen bus linked to the module?

It utilizes an integrated T-connector interface, allowing for direct loop-through connection of the fieldbus line without external splitters.

Is the IP1010-B518 suitable for washdown environments?

Yes, it features an IP67 protection rating, making it dust-tight and resistant to water ingress, ideal for mounting directly on machinery.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.