BECKHOFF

BECKHOFF ER2809-0022 EtherCAT Box 16-Channel Digital Output Module

SKU ER2809-0022

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: ER2809-0022

  • Country of origin:Germany

  • Product Type: EtherCAT Boxes

  • Payment: T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF ER2809-0022 EtherCAT Box is a modular industrial input/output device designed for machine-level applications without control cabinets. Equipped with 16 digital outputs, this compact module connects directly to the EtherCAT network to provide reliable switching of field devices. Housed in a durable, fully potted industrial enclosure, it is engineered to handle demanding factory environments while maintaining high-speed real-time communication performance.

This exact model features M12 connection technology for its output channels, supporting ohmic, inductive, and lamp loads with individual short-circuit protection. Power is supplied via standardized M8 connectors, allowing straightforward integration into decentralized machine topologies. The robust design eliminates the need for protective cabinets, reducing cabling effort and simplifying installation close to the actuators.

Features

  • 16 digital outputs housed in a decentralized EtherCAT Box module
  • M12 x 1, 5-pin, A-coded output connections for reliable sensor and actuator wiring
  • Supports ohmic, inductive, and lamp loads
  • Nominal output voltage of 24 V DC with individual short-circuit protection per channel
  • Dual M8 sockets for shielded EtherCAT bus interface daisy-chaining
  • Integrated power supply connection via M8 male feed and M8 female downstream sockets
  • IP65, IP66, and IP67 protection ratings for harsh industrial environments

Applications

  • Decentralized automation architectures without control cabinets
  • High-density digital actuator control in factory machinery
  • Automated material handling and conveyor systems
  • Packaging and sorting equipment requiring distributed I/O
  • Machine tool peripherals and assembly lines

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model ER2809-0022
Product Type EtherCAT Box
Protocol EtherCAT

Digital Outputs

Parameter Specification
Number of Outputs 16
Nominal Output Voltage 24 V DC (-15 percent / +20 percent)
Max. Output Current 0.5 A per channel, individually short-circuit proof (sum current 4 A)
Load Type Ohmic, inductive, lamp load
Switching Times Typ. Ton: 60 us, typ. Toff: 300 us
Short-Circuit Current Max. 1.5 A
Distributed Clocks Not supported

Electrical and Power Supply

Parameter Specification
Current Consumption from Us Typ. 130 mA
Auxiliary Power Current Typ. 20 mA plus load
Electrical Isolation 500 V

Connections and Interfaces

Parameter Specification
Bus Interface 2 x M8 socket, shielded, screw type
Output Connections M12 x 1, 5-pin, A-coded
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin

Mechanical and Environmental

Parameter Specification
Weight Approx. 450 g
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable

Approvals and Certifications

Parameter Specification
Approvals / Markings CE, UL

Installation Guidelines

  1. Ensure the machine or system is completely de-energized and locked out before beginning installation or wiring work.
  2. Inspect the BECKHOFF ER2809-0022 module and connectors for any visible shipping damage or contamination.
  3. Mount the EtherCAT Box securely onto a flat machine surface using the designated fixing holes in any variable orientation.
  4. Connect the incoming and outgoing shielded EtherCAT cables to the M8 bus sockets to maintain network integrity.
  5. Attach the 24 V DC power feed and downstream supply cables using the M8 power connectors, ensuring correct polarity and voltage limits.
  6. Wire actuators to the M12 output ports, verifying that individual channel load limits and total sum currents are not exceeded.
  7. Verify all connections, power up the system, and check module diagnostic LEDs during commissioning.

FAQ

What is the primary function of the BECKHOFF ER2809-0022?

The BECKHOFF ER2809-0022 is a decentralized EtherCAT Box module that provides 16 digital outputs for connecting industrial actuators and loads directly in the field without requiring a control cabinet.

How many outputs does the BECKHOFF ER2809-0022 feature and what is their current rating?

The BECKHOFF ER2809-0022 features 16 digital outputs with a maximum output current of 0.5 A per channel, individually short-circuit protected, with a total sum current limit of 4 A.

What type of connectors are used for the outputs and communication on the ER2809-0022?

The BECKHOFF ER2809-0022 utilizes M12 x 1, 5-pin, A-coded connectors for its 16 digital outputs and shielded M8 sockets for the EtherCAT bus interface.

What environmental protection rating does the BECKHOFF ER2809-0022 have?

The BECKHOFF ER2809-0022 offers IP65, IP66, and IP67 protection ratings, making it fully dust-tight and protected against water jets and temporary immersion in harsh industrial environments.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.