The BECKHOFF IP1502-B318 is a specialized fieldbus box designed for direct field-level digital input and high-speed counter applications within PROFIBUS DP networks. Equipped with two independent 32-bit counter channels, this field-level module is engineered for decentralized automation tasks requiring precise position, frequency, or pulse detection. Its IP67-rated construction allows for direct mounting on machinery, eliminating the need for protective control cabinets and minimizing field-wiring runs.

This module features two counter inputs capable of processing signal frequencies up to 100 kHz, alongside two auxiliary gate inputs and two up/down direction switches. Built-in industrial M12 screw-type connectors ensure secure, vibration-resistant connections for sensors and actuator signals, while the integrated B-coded M12 T-connector facilitates straightforward PROFIBUS network daisy-chaining without external splitters.

Features

  • Two high-speed 32-bit counter channels supporting input frequencies up to 100 kHz.
  • Integrated PROFIBUS DP communication interface with automatic baud rate detection up to 12 Mbaud.
  • Direct field-level installation with IP65, IP66, and IP67 environmental protection ratings.
  • Built-in M12 T-connector for direct, simplified PROFIBUS network wiring.
  • Auxiliary gate inputs and direction control switches for flexible counter operations.
  • Short-circuit proof 24 V DC sensor supply sourced from the control voltage.
  • Durable polyamide (PA6) housing designed to withstand industrial mechanical stresses.

Applications

  • High-speed position and distance measurement using incremental encoders or pulse generators.
  • Part counting, flow measurement, and frequency monitoring in automated processing lines.
  • Decentralized industrial installations requiring field-level sensor integration without control cabinets.
  • Material handling and conveyor systems utilizing PROFIBUS DP communication.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1502-B318
Product Type Fieldbus Box (Counter Module)
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Mounting Method 2 fixing holes (3.5 mm diameter for M3)
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals CE, UL

Signal and Counter Inputs

Parameter Specification
Number of Inputs 2 counter inputs, 2 gate inputs, 2 up/down switches
Number of Counters 2 (each with a depth of 32 bits)
Counting Frequency 100 kHz (2 kHz for up/down switching)
Signal Connection M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage Range -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage Range 11 to 30 V (EN 61131-2, type 2)
Number of Outputs 2 x 24 V DC, 0.5 A (individually short-circuit proof)
Sensor Supply From control voltage, max. 0.5 A total (short-circuit proof)
Process Image Bit Width 80 inputs/outputs: 2 x 32-bit data, 2 x 8-bit control/status

Electrical and Power

Parameter Specification
Control Voltage Supply 24 V DC (-15% / +20%)
Box Supply Current 85 mA + sensor current (max. 0.5 A)
Power Supply Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Electrical Isolation Control voltage/fieldbus: No; Channels/control voltage: No

Fieldbus and Communication

Parameter Specification
Fieldbus System PROFIBUS DP
Data Transfer Rates Automatic detection up to 12 Mbaud
Bus Interface Connection 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded, integrated T-connector
Configuration Options Via KS2000 software or the master controller (supports DP-V1 extensions)

Installation Guidelines

  1. Verify the exact model (IP1502-B318) and check the housing and connectors for any visual damage before beginning installation.
  2. Ensure that all power supply lines are completely de-energized and locked out prior to mounting or connecting the module.
  3. Secure the fieldbus box to a flat, rigid mounting surface using the two 3.5 mm integrated mounting holes with appropriate M3 screws. Do not over-torque.
  4. Connect the PROFIBUS network lines to the B-coded M12 interface. Ensure both the incoming and outgoing connections are properly seated and hand-tightened to maintain the environmental seal.
  5. Connect the 24 V DC control voltage power source to the M8 feed connector. If daisy-chaining power to adjacent boxes, connect the downstream M8 female connector to the next device.
  6. Wire the signal sensors and actuator connections using the designated M12 screw-type interfaces.
  7. Seal any unused M12 or M8 connectors with IP-rated protective caps to ensure compliance with the IP65/66/67 protection standards.

FAQ

What is the primary function of the BECKHOFF IP1502-B318?

The BECKHOFF IP1502-B318 is a decentralized, 2-channel digital input counter fieldbus box designed to process high-speed pulse inputs up to 100 kHz and interface with a PROFIBUS DP control network.

What type of fieldbus interface does the IP1502-B318 use?

The BECKHOFF IP1502-B318 uses a PROFIBUS DP interface featuring B-coded M12 connections, consisting of one 5-pin socket and one 5-pin plug with an integrated T-connector for direct daisy-chaining.

Can the BECKHOFF IP1502-B318 be installed without an electrical enclosure?

Yes, the BECKHOFF IP1502-B318 features an IP65/66/67 environmental protection rating, allowing direct field-level installation directly on machinery without an external control cabinet.

What are the power connection requirements for the IP1502-B318?

The BECKHOFF IP1502-B318 utilizes a 4-pin M8 male plug for its primary 24 V DC power feed and a 4-pin M8 female socket to distribute downstream power to other fieldbus modules.

What types of inputs are available on the IP1502-B318?

The BECKHOFF IP1502-B318 contains 2 counter inputs (32-bit depth), 2 gate inputs, and 2 up/down switches to control counting direction.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.