The BECKHOFF IP1502-B318 is a specialized fieldbus box designed for direct field-level digital input and high-speed counter applications within PROFIBUS DP networks. Equipped with two independent 32-bit counter channels, this field-level module is engineered for decentralized automation tasks requiring precise position, frequency, or pulse detection. Its IP67-rated construction allows for direct mounting on machinery, eliminating the need for protective control cabinets and minimizing field-wiring runs.

This module features two counter inputs capable of processing signal frequencies up to 100 kHz, alongside two auxiliary gate inputs and two up/down direction switches. Built-in industrial M12 screw-type connectors ensure secure, vibration-resistant connections for sensors and actuator signals, while the integrated B-coded M12 T-connector facilitates straightforward PROFIBUS network daisy-chaining without external splitters.

Features

  • Two high-speed 32-bit counter channels supporting input frequencies up to 100 kHz.
  • Integrated PROFIBUS DP communication interface with automatic baud rate detection up to 12 Mbaud.
  • Direct field-level installation with IP65, IP66, and IP67 environmental protection ratings.
  • Built-in M12 T-connector for direct, simplified PROFIBUS network wiring.
  • Auxiliary gate inputs and direction control switches for flexible counter operations.
  • Short-circuit proof 24 V DC sensor supply sourced from the control voltage.
  • Durable polyamide (PA6) housing designed to withstand industrial mechanical stresses.

Applications

  • High-speed position and distance measurement using incremental encoders or pulse generators.
  • Part counting, flow measurement, and frequency monitoring in automated processing lines.
  • Decentralized industrial installations requiring field-level sensor integration without control cabinets.
  • Material handling and conveyor systems utilizing PROFIBUS DP communication.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1502-B318
Product Type Fieldbus Box (Counter Module)
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Mounting Method 2 fixing holes (3.5 mm diameter for M3)
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals CE, UL

Signal and Counter Inputs

Parameter Specification
Number of Inputs 2 counter inputs, 2 gate inputs, 2 up/down switches
Number of Counters 2 (each with a depth of 32 bits)
Counting Frequency 100 kHz (2 kHz for up/down switching)
Signal Connection M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage Range -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage Range 11 to 30 V (EN 61131-2, type 2)
Number of Outputs 2 x 24 V DC, 0.5 A (individually short-circuit proof)
Sensor Supply From control voltage, max. 0.5 A total (short-circuit proof)
Process Image Bit Width 80 inputs/outputs: 2 x 32-bit data, 2 x 8-bit control/status

Electrical and Power

Parameter Specification
Control Voltage Supply 24 V DC (-15% / +20%)
Box Supply Current 85 mA + sensor current (max. 0.5 A)
Power Supply Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Electrical Isolation Control voltage/fieldbus: No; Channels/control voltage: No

Fieldbus and Communication

Parameter Specification
Fieldbus System PROFIBUS DP
Data Transfer Rates Automatic detection up to 12 Mbaud
Bus Interface Connection 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded, integrated T-connector
Configuration Options Via KS2000 software or the master controller (supports DP-V1 extensions)

Installation Guidelines

  1. Verify the exact model (IP1502-B318) and check the housing and connectors for any visual damage before beginning installation.
  2. Ensure that all power supply lines are completely de-energized and locked out prior to mounting or connecting the module.
  3. Secure the fieldbus box to a flat, rigid mounting surface using the two 3.5 mm integrated mounting holes with appropriate M3 screws. Do not over-torque.
  4. Connect the PROFIBUS network lines to the B-coded M12 interface. Ensure both the incoming and outgoing connections are properly seated and hand-tightened to maintain the environmental seal.
  5. Connect the 24 V DC control voltage power source to the M8 feed connector. If daisy-chaining power to adjacent boxes, connect the downstream M8 female connector to the next device.
  6. Wire the signal sensors and actuator connections using the designated M12 screw-type interfaces.
  7. Seal any unused M12 or M8 connectors with IP-rated protective caps to ensure compliance with the IP65/66/67 protection standards.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP1502-B318?
The BECKHOFF IP1502-B318 is a decentralized, 2-channel digital input counter fieldbus box designed to process high-speed pulse inputs up to 100 kHz and interface with a PROFIBUS DP control network.
What type of fieldbus interface does the IP1502-B318 use?
The BECKHOFF IP1502-B318 uses a PROFIBUS DP interface featuring B-coded M12 connections, consisting of one 5-pin socket and one 5-pin plug with an integrated T-connector for direct daisy-chaining.
Can the BECKHOFF IP1502-B318 be installed without an electrical enclosure?
Yes, the BECKHOFF IP1502-B318 features an IP65/66/67 environmental protection rating, allowing direct field-level installation directly on machinery without an external control cabinet.
What are the power connection requirements for the IP1502-B318?
The BECKHOFF IP1502-B318 utilizes a 4-pin M8 male plug for its primary 24 V DC power feed and a 4-pin M8 female socket to distribute downstream power to other fieldbus modules.
What types of inputs are available on the IP1502-B318?
The BECKHOFF IP1502-B318 contains 2 counter inputs (32-bit depth), 2 gate inputs, and 2 up/down switches to control counting direction.
Reviews

IP1502-B318

Stock & lead time on request

Call
1 of 1

BECKHOFF IP1502-B318 PROFIBUS Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP1502-B318

  • Country of origin:Germany

  • Product Type: Fieldbus Box Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 30 mm x 210 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF IP1502-B318 is a specialized fieldbus box designed for direct field-level digital input and high-speed counter applications within PROFIBUS DP networks. Equipped with two independent 32-bit counter channels, this field-level module is engineered for decentralized automation tasks requiring precise position, frequency, or pulse detection. Its IP67-rated construction allows for direct mounting on machinery, eliminating the need for protective control cabinets and minimizing field-wiring runs.

This module features two counter inputs capable of processing signal frequencies up to 100 kHz, alongside two auxiliary gate inputs and two up/down direction switches. Built-in industrial M12 screw-type connectors ensure secure, vibration-resistant connections for sensors and actuator signals, while the integrated B-coded M12 T-connector facilitates straightforward PROFIBUS network daisy-chaining without external splitters.

Features

  • Two high-speed 32-bit counter channels supporting input frequencies up to 100 kHz.
  • Integrated PROFIBUS DP communication interface with automatic baud rate detection up to 12 Mbaud.
  • Direct field-level installation with IP65, IP66, and IP67 environmental protection ratings.
  • Built-in M12 T-connector for direct, simplified PROFIBUS network wiring.
  • Auxiliary gate inputs and direction control switches for flexible counter operations.
  • Short-circuit proof 24 V DC sensor supply sourced from the control voltage.
  • Durable polyamide (PA6) housing designed to withstand industrial mechanical stresses.

Applications

  • High-speed position and distance measurement using incremental encoders or pulse generators.
  • Part counting, flow measurement, and frequency monitoring in automated processing lines.
  • Decentralized industrial installations requiring field-level sensor integration without control cabinets.
  • Material handling and conveyor systems utilizing PROFIBUS DP communication.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1502-B318
Product Type Fieldbus Box (Counter Module)
Housing Material PA6 (Polyamide)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Mounting Method 2 fixing holes (3.5 mm diameter for M3)
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 and EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals CE, UL

Signal and Counter Inputs

Parameter Specification
Number of Inputs 2 counter inputs, 2 gate inputs, 2 up/down switches
Number of Counters 2 (each with a depth of 32 bits)
Counting Frequency 100 kHz (2 kHz for up/down switching)
Signal Connection M12, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage Range -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage Range 11 to 30 V (EN 61131-2, type 2)
Number of Outputs 2 x 24 V DC, 0.5 A (individually short-circuit proof)
Sensor Supply From control voltage, max. 0.5 A total (short-circuit proof)
Process Image Bit Width 80 inputs/outputs: 2 x 32-bit data, 2 x 8-bit control/status

Electrical and Power

Parameter Specification
Control Voltage Supply 24 V DC (-15% / +20%)
Box Supply Current 85 mA + sensor current (max. 0.5 A)
Power Supply Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Electrical Isolation Control voltage/fieldbus: No; Channels/control voltage: No

Fieldbus and Communication

Parameter Specification
Fieldbus System PROFIBUS DP
Data Transfer Rates Automatic detection up to 12 Mbaud
Bus Interface Connection 1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded, integrated T-connector
Configuration Options Via KS2000 software or the master controller (supports DP-V1 extensions)

Installation Guidelines

  1. Verify the exact model (IP1502-B318) and check the housing and connectors for any visual damage before beginning installation.
  2. Ensure that all power supply lines are completely de-energized and locked out prior to mounting or connecting the module.
  3. Secure the fieldbus box to a flat, rigid mounting surface using the two 3.5 mm integrated mounting holes with appropriate M3 screws. Do not over-torque.
  4. Connect the PROFIBUS network lines to the B-coded M12 interface. Ensure both the incoming and outgoing connections are properly seated and hand-tightened to maintain the environmental seal.
  5. Connect the 24 V DC control voltage power source to the M8 feed connector. If daisy-chaining power to adjacent boxes, connect the downstream M8 female connector to the next device.
  6. Wire the signal sensors and actuator connections using the designated M12 screw-type interfaces.
  7. Seal any unused M12 or M8 connectors with IP-rated protective caps to ensure compliance with the IP65/66/67 protection standards.
Loading product navigation…

What is the primary function of the BECKHOFF IP1502-B318?

The BECKHOFF IP1502-B318 is a decentralized, 2-channel digital input counter fieldbus box designed to process high-speed pulse inputs up to 100 kHz and interface with a PROFIBUS DP control network.

What type of fieldbus interface does the IP1502-B318 use?

The BECKHOFF IP1502-B318 uses a PROFIBUS DP interface featuring B-coded M12 connections, consisting of one 5-pin socket and one 5-pin plug with an integrated T-connector for direct daisy-chaining.

Can the BECKHOFF IP1502-B318 be installed without an electrical enclosure?

Yes, the BECKHOFF IP1502-B318 features an IP65/66/67 environmental protection rating, allowing direct field-level installation directly on machinery without an external control cabinet.

What are the power connection requirements for the IP1502-B318?

The BECKHOFF IP1502-B318 utilizes a 4-pin M8 male plug for its primary 24 V DC power feed and a 4-pin M8 female socket to distribute downstream power to other fieldbus modules.

What types of inputs are available on the IP1502-B318?

The BECKHOFF IP1502-B318 contains 2 counter inputs (32-bit depth), 2 gate inputs, and 2 up/down switches to control counting direction.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...