Description
Designed for direct decentralised installation on machinery without requiring protective control cabinets, the Beckhoff IP2041-B318 digital output module interfaces binary control signals with the PROFIBUS DP network. This Fieldbus Box accommodates eight digital outputs, each handling high load currents up to 2 A (with a total combined module current capacity of 12 A). The module uses space-saving M8 screw-type connectors for secure I/O coupling, and features an integrated B-coded M12 T-connector to simplify PROFIBUS loop-through cabling.
The IP2041-B318 supports DP-V1 extensions and can be configured through the KS2000 software suite or directly via the master controller. Its robust polyamide construction is sealed to IP67 standards, making it highly resilient against moisture, dust, and mechanical stress in demanding production environments.
Features
- Eight independent 24 V DC digital outputs rated for resistive, inductive, and lamp loads.
- Individually short-circuit proof outputs with a nominal channel capacity of 2 A.
- High total power handling, supporting up to 12 A total current across output groups.
- Integrated M12 B-coded T-connector (1x plug, 1x socket) for direct PROFIBUS network distribution.
- Automatic fieldbus baud rate detection up to 12 Mbaud.
- IP65, IP66, and IP67 dust and moisture ingress protection.
- Configuration accessibility via the KS2000 commissioning tool or the host controller.
Applications
- Machine tool and processing center integration
- Conveyor and material handling automation
- Packaging and bottling plants
- Assembly lines and robotics platforms
Technical Specifications
| Manufacturer |
Beckhoff |
| Part Number / Model |
IP2041-B318 |
| Protocol / Interface |
PROFIBUS DP |
| Number of Outputs |
8 digital outputs |
| Nominal Output Voltage |
24 V DC (-15% / +20%) |
| Max. Output Current |
2 A per channel (total max. 12 A; Channel 0 to 3: sum 4 A, Channel 4 to 5: sum 4 A, Channel 6 to 7: sum 4 A) |
| Short-Circuit Current |
typical 4 A |
| Data Transfer Rates |
Automatic detection up to 12 Mbaud |
| Bus Connection |
1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded, integrated T-connector |
| Power Feed Connections |
2 x M8 male socket, 4-pin (no downstream connection) |
| Box Supply Current |
85 mA + sensor current consumption (max. 0.5 A) |
| Auxiliary Power Current |
typical 50 mA per channel |
| Housing Type |
XXL housing |
| Housing Material |
PA6 (polyamide) |
| Dimensions (W x H x D) |
30 mm x 210 mm x 26.5 mm |
| Operating Temperature |
0 to +55 degC |
| Storage Temperature |
-25 to +85 degC |
| Vibration / Shock Resistance |
Conforms to EN 60068-2-6 / EN 60068-2-27 |
| EMC Immunity / Emission |
Conforms to EN 61000-6-2 / EN 61000-6-4 |
| Protection Class |
IP65, IP66, IP67 (conforms to EN 60529) |
Connections and Interfaces
| Interface Type |
Connector Style |
Function / Pin Assignment |
| PROFIBUS DP |
M12 (1x socket, 1x plug), B-coded |
Incoming and outgoing bus loop (integrated T-connector) |
| Outputs (0 to 7) |
M8, screw-type |
Actuator / output channel connections |
| Power Supply Feed |
2x M8 male socket, 4-pin |
Control voltage and load voltage inputs |
Installation Guidelines
- Mount the module directly to the machinery frame using the two 3.5 mm diameter fixing holes intended for M3 screws.
- Ensure all unused M8 and M12 ports are sealed with approved IP67-rated protective caps to maintain environmental sealing.
- Route communication cables separately from high-voltage power lines to minimize potential electromagnetic interference.
- Ensure grounding connection is properly made to the machine body to guarantee EMC compliance and system stability.
Compliance and Certifications