The BECKHOFF IP2041-B810 is an IP67-rated decentralized Fieldbus Box module designed to switch high-capacity digital output signals in demanding industrial automation environments. This module provides 8 digital output channels and interfaces with host controllers via an RS232 serial interface, enabling direct installation on machinery and eliminating the need for protective control cabinets.

With an IP67 protection class, the BECKHOFF IP2041-B810 is protected against dust and water ingress, making it suitable for distributed I/O architectures in wet, dirty, or space-constrained areas. The outputs are engineered for switching high-current actuators and connect directly using industry-standard M8 screw-type connection technology.

Features

  • 8 digital outputs rated for switching actuators directly in the field.
  • Integrated RS232 serial interface for local control and diagnostic integration.
  • High current capacity of up to 2 A per channel with a maximum sum current limit of 12 A.
  • IP67-rated housing for cabinet-free installation in harsh industrial environments.
  • M8 connection technology ensuring secure, vibration-resistant cable connections.

Applications

  • Decentralized control systems requiring direct actuator switching at the machine level.
  • Cabinet-free machine building, material handling, and assembly line systems.
  • Point-to-point RS232 communication architectures where localized high-current digital outputs are required.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Number IP2041-B810
Product Type Fieldbus Box (IP67)
Number of Outputs 8 digital outputs
Output Current Max. 2 A per channel
Sum Current Limit Max. 12 A total across all channels
Fieldbus Interface RS232 serial communication
Output Connection M8, 3-pin screw-type connectors
Operating Voltage 24 V DC (control and load supply)
Protection Rating IP67 (dust tight, water resistant)

Installation Guidelines

  1. Ensure that all electrical power sources are de-energized before beginning installation or maintenance.
  2. Securely mount the IP2041-B810 module directly to a flat machine surface using the integrated mounting holes.
  3. Connect the 24 V DC power supply lines, keeping load voltage and control voltage channels separated if required.
  4. Attach the RS232 serial interface cable to the dedicated communication port on the box.
  5. Connect the actuators to the corresponding M8 output channels, ensuring the cables are properly tightened to maintain the IP67 seal.
  6. To prevent water ingress, seal all unused M8 and communication ports with water-tight protective caps.
  7. Apply power and verify that the status LEDs illuminate correctly to indicate proper communication and channel states.

Replacement Recommendations

When replacing an existing BECKHOFF IP2041-B810, verify that the replacement unit shares the identical model and suffix to prevent communication mismatches. Ensure the serial baud rate, data bits, and parity configuration in the host controller align with the RS232 interface settings of the new box. Always power down the system completely before swapping signal cables or the power supply connector.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2041-B810?
The BECKHOFF IP2041-B810 is an IP67-rated Fieldbus Box designed to control 8 digital output channels (up to 2 A each) over an RS232 serial communication network directly in cabinet-free environments.
What is the maximum electrical capacity of the outputs on the IP2041-B810?
Each of the 8 digital outputs on the BECKHOFF IP2041-B810 can carry a maximum load of 2 A, provided that the total sum current across all outputs does not exceed 12 A.
How is the physical sealing of the IP2041-B810 maintained?
To maintain the IP67 environmental rating on the BECKHOFF IP2041-B810, all connected M8 cables must be screwed on securely, and any unused ports must be capped with water-tight protective seals.
What communication protocol is used by the IP2041-B810?
The BECKHOFF IP2041-B810 features an RS232 interface, allowing serial command sequences or specific point-to-point protocols to be used for module control and diagnosis.
Reviews

IP2041-B810

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2041-B810 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2041-B810

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2041-B810 is an IP67-rated decentralized Fieldbus Box module designed to switch high-capacity digital output signals in demanding industrial automation environments. This module provides 8 digital output channels and interfaces with host controllers via an RS232 serial interface, enabling direct installation on machinery and eliminating the need for protective control cabinets.

With an IP67 protection class, the BECKHOFF IP2041-B810 is protected against dust and water ingress, making it suitable for distributed I/O architectures in wet, dirty, or space-constrained areas. The outputs are engineered for switching high-current actuators and connect directly using industry-standard M8 screw-type connection technology.

Features

  • 8 digital outputs rated for switching actuators directly in the field.
  • Integrated RS232 serial interface for local control and diagnostic integration.
  • High current capacity of up to 2 A per channel with a maximum sum current limit of 12 A.
  • IP67-rated housing for cabinet-free installation in harsh industrial environments.
  • M8 connection technology ensuring secure, vibration-resistant cable connections.

Applications

  • Decentralized control systems requiring direct actuator switching at the machine level.
  • Cabinet-free machine building, material handling, and assembly line systems.
  • Point-to-point RS232 communication architectures where localized high-current digital outputs are required.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Number IP2041-B810
Product Type Fieldbus Box (IP67)
Number of Outputs 8 digital outputs
Output Current Max. 2 A per channel
Sum Current Limit Max. 12 A total across all channels
Fieldbus Interface RS232 serial communication
Output Connection M8, 3-pin screw-type connectors
Operating Voltage 24 V DC (control and load supply)
Protection Rating IP67 (dust tight, water resistant)

Installation Guidelines

  1. Ensure that all electrical power sources are de-energized before beginning installation or maintenance.
  2. Securely mount the IP2041-B810 module directly to a flat machine surface using the integrated mounting holes.
  3. Connect the 24 V DC power supply lines, keeping load voltage and control voltage channels separated if required.
  4. Attach the RS232 serial interface cable to the dedicated communication port on the box.
  5. Connect the actuators to the corresponding M8 output channels, ensuring the cables are properly tightened to maintain the IP67 seal.
  6. To prevent water ingress, seal all unused M8 and communication ports with water-tight protective caps.
  7. Apply power and verify that the status LEDs illuminate correctly to indicate proper communication and channel states.

Replacement Recommendations

When replacing an existing BECKHOFF IP2041-B810, verify that the replacement unit shares the identical model and suffix to prevent communication mismatches. Ensure the serial baud rate, data bits, and parity configuration in the host controller align with the RS232 interface settings of the new box. Always power down the system completely before swapping signal cables or the power supply connector.

Loading product navigation…

What is the primary function of the BECKHOFF IP2041-B810?

The BECKHOFF IP2041-B810 is an IP67-rated Fieldbus Box designed to control 8 digital output channels (up to 2 A each) over an RS232 serial communication network directly in cabinet-free environments.

What is the maximum electrical capacity of the outputs on the IP2041-B810?

Each of the 8 digital outputs on the BECKHOFF IP2041-B810 can carry a maximum load of 2 A, provided that the total sum current across all outputs does not exceed 12 A.

How is the physical sealing of the IP2041-B810 maintained?

To maintain the IP67 environmental rating on the BECKHOFF IP2041-B810, all connected M8 cables must be screwed on securely, and any unused ports must be capped with water-tight protective seals.

What communication protocol is used by the IP2041-B810?

The BECKHOFF IP2041-B810 features an RS232 interface, allowing serial command sequences or specific point-to-point protocols to be used for module control and diagnosis.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...