1 of 1

Beckhoff IP2042-B518 Fieldbus Box 8-Channel Digital Output Module

Beckhoff IP2042-B518 Fieldbus Box 8-Channel Digital Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2042-B518

  • Country of origin:Germany

  • Product Type: Fieldbus I/O Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 30 mm x 210 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for decentralized control architectures, the Beckhoff IP2042-B518 operates as a high-performance Fieldbus Box distributing 8 digital output channels directly in rugged field environments via a CANopen interface. This robust device allows the direct connection of 24 V DC actuators, such as solenoid valves, contactors, and indicators, without requiring an additional protective terminal enclosure. Featuring integrated T-connector bus interfaces and M12 output connections, it offers an exceptionally high output capacity of up to 2 A per channel (12 A cumulative total), ensuring reliable power distribution in high-load industrial applications.

Features

  • High Current Output: Employs 8 digital channels handling 2 A each, individually protected against short circuits.
  • Integrated T-Connector: Simplifies network trunk line wiring with a pre-integrated M12 daisy-chain interface.
  • Automatic Network Adaptation: Instantly detects communication speeds from 10 kbaud up to 1 Mbaud on the CANopen network.
  • Environmentally Sealed Housing: Standard XXL polyamide casing with IP65, IP66, and IP67 protection ratings.
  • Advanced Diagnostics: Built-in variable mapping, emergency objects, and Node/Life Guarding options for reliable network status tracking.

Applications

  • Decentralized packaging machine lines requiring direct, cabinet-free mounting.
  • Automotive assembly automation with high-density localized actuator clusters.
  • Heavy material handling and conveyor automation systems.
  • Pneumatic valve manifold control and distributed solenoid piloting.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Reference IP2042-B518
Output Count 8 digital outputs
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 2 A per channel (short-circuit proof)
Aggregate Output Limit Max. 12 A (Ch 0-3: sum 4 A | Ch 4-5: sum 4 A | Ch 6-7: sum 4 A)
Fieldbus System CANopen (up to 16 Rx / 16 Tx PDOs)
Baud Rates 10 kbaud to 1 Mbaud (automatic auto-detection)
Control Voltage Current Draw 45 mA + sensor current load (max 0.5 A)
Electrical Isolation Control voltage to fieldbus: 500 V
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Environmental Protection IP65/66/67 (conforms to EN 60529)
Housing Material Polyamide PA6
Device Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector / Terminal Type Pin Number Function / Signal Assignment
CANopen Bus Interface (M12) Pin 1 Shield / Functional Earth
Pin 2 V+ (Bus Power, optional)
Pin 3 CAN Ground (GND)
Pin 4 CAN High (CAN_H)
Pin 5 CAN Low (CAN_L)
Power Supply Inlet (M8 Feed) Pin 1 Control Voltage +24 V DC (Us)
Pin 2 Load Voltage +24 V DC (Up)
Pin 3 GND Us
Pin 4 GND Up

Alternative Models & Compatibility

The IP2042-B518 is fully compatible with standard Beckhoff CANopen structures. It serves as a direct drop-in replacement for equivalent legacy IP2042 modules using the -B510 and -B518 variants. Users upgrading or replacing modules must ensure that the master PLC controller possesses the correct EDS file to support the extended diagnostics and flexible variable mapping capabilities of the -B518 series.

Application Pitfalls & Engineering Notes

Pay close attention to internal power budget grouping rules. While individual channels are short-circuit protected and rated for 2 A, physical thermal constraints within the housing limit aggregate current draws. Specifically, channels 0-3 must not exceed a combined total of 4 A; channels 4-5 must not exceed 4 A; and channels 6-7 are restricted to 4 A. Exceeding these thermal grouped limits can cause regional shut-down or local safety tripping.

Commissioning & Wiring Tips

To optimize signaling efficiency on long CANopen network segments, always utilize properly shielded, twisted-pair copper cabling specifically designed for industrial CAN networks. Additionally, a 120-ohm bus termination resistor must be installed on the unused M12 port if this specific module constitutes the physically final node on the CANopen network bus trunk line.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources (control voltage Us and load voltage Up) prior to mechanical installation, cable connection, or hardware service. Failure to de-energize circuits may cause localized arc faults, damage internal solid-state components, and compromise the network interface.

1
Position the module on a flat mounting surface and align the physical fixing points. Securely mount using two 3.5 mm diameter M3 screws. Do not over-torque.
2
Connect the incoming CANopen network feed line to the integrated M12 plug interface, and loop output networks using the integrated M12 socket.
3
Attach the M8 supply cabling, verifying separate wiring paths for the control voltage (Us) and output load voltage (Up). Tighten the lock rings to ensure an IP67 liquid-tight seal.
Loading product navigation…

What are the channel group current limits for the IP2042-B518?

While each channel supports up to 2 A individually, the module has sum limits: channels 0 to 3 are capped at 4 A total, channels 4 and 5 at 4 A, and channels 6 and 7 at 4 A. The overall maximum module current is 12 A.

Does this Fieldbus Box require a separate CANopen termination resistor?

Yes. If the IP2042-B518 is the last physical device on the CANopen bus trunk, a matching 120-ohm termination resistor must be installed on the outgoing M12 bus connection.

How do I configure the baud rate on this module?

The module features automatic baud rate detection ranging from 10 kbaud up to 1 Mbaud, aligning itself with the active master on the network automatically.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...