BECKHOFF

Beckhoff IP2000-B318 Fieldbus Box Digital Output Module

SKU IP2000-B318

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: IP2000-B318

  • Country of origin:Germany

  • Product Type: Fieldbus Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Decentralized automation processes in harsh machine environments require robust, cabinet-free I/O interfaces. The IP2000-B318 Fieldbus Box serves as a reliable distributed interface, linking up to eight binary actuator control signals directly to a PROFIBUS network. Engineered with an IP67 rating, this module facilitates direct machine mounting, drastically reducing field wiring complexity and cabling costs.

Operating with a standard 24 V DC control voltage, the module distributes power and signal logic to eight independent digital outputs, each capable of delivering up to 0.5 A of load current. Standardized Ø8 mm snap-on connectors ensure fast, secure connection of field cables, while the integrated T-connector design facilitates straightforward loop-through of the PROFIBUS network lines directly on the module body.

Features

  • Direct Fieldbus Coupling: Native support for PROFIBUS DP protocol networks with integrated T-connector topology.
  • High-Density Outputs: 8 digital outputs rated at 24 V DC, 0.5 A per channel with integrated short-circuit protection.
  • Rugged Enclosure: Fully encapsulated IP67-rated housing designed for direct machine installation without protective enclosures.
  • Quick Installation: Standardized Ø8 mm snap-on connections minimize installation downtime and wiring errors.
  • Status Indicators: High-visibility LED diagnostic displays for network status and channel-specific logical output states.

Applications

  • Automotive assembly lines and robotic cell integration
  • Packaging, sorting, and material handling systems
  • Pneumatic valve terminal control and decentralized actuator block management
  • Conveyor systems and general machinery engineering

Technical Specifications

Manufacturer Beckhoff Automation GmbH & Co. KG
Part Number / Model IP2000-B318
Product Series Fieldbus Box (IPxxxx Series)
Fieldbus Interface PROFIBUS DP
Number of Outputs 8 digital outputs
Nominal Output Voltage 24 V DC (-15% / +20%)
Load Current per Channel 0.5 A (short-circuit proof)
Signal Connection 8 x Ø8 mm snap-on connectors
Bus Connection Integrated T-connector (PROFIBUS IN/OUT)
Protection Rating IP67
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Approximate Weight 2.0 kg (shipping weight weight-adjusted)

Installation Guidelines

  • Mechanical Mounting: Fasten the unit securely to a flat surface using the integrated mounting holes. Ensure that no mechanical stresses are applied to the housing structure.
  • Functional Grounding: Establish a low-impedance connection between the module ground and the machine ground plane to ensure electromagnetic compatibility (EMC).
  • Cabling and Shielding: Utilize shielded PROFIBUS cables. Route fieldbus lines away from high-voltage cables or motor drive leads to prevent signal distortion.
  • Unused Interfaces: Seal any unused Ø8 mm signal sockets or PROFIBUS connectors with appropriate protective IP67 sealing caps to maintain the ingress protection rating.

FAQ

What is the primary function of the Beckhoff IP2000-B318?

The Beckhoff IP2000-B318 is an IP67-rated decentralized Fieldbus Box designed to connect 8 binary digital outputs directly to a PROFIBUS DP network.

What connector size is used for the output signals?

This module utilizes standardized Ø8 mm snap-on connectors for secure, fast-mating field wiring.

What is the rated load current for each digital output channel?

Each output channel is rated for up to 0.5 A at 24 V DC and features short-circuit protection.

Can the PROFIBUS lines be looped through this module directly?

Yes, the IP2000-B318 features an integrated T-connector design, allowing the PROFIBUS network to be easily routed to subsequent nodes without auxiliary splitters.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...