1 of 1

Beckhoff IP2300-B510 Fieldbus Box 4-Channel Digital Input + 4-Channel Digital Output

Beckhoff IP2300-B510 Fieldbus Box 4-Channel Digital Input + 4-Channel Digital Output

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2300-B510

  • Country of origin:Germany

  • Product Type: Fieldbus Box Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 220 mm x 110 mm x 60 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

To facilitate distributed decentralized I/O acquisition in harsh industrial environments, the Beckhoff IP2300-B510 integrates discrete inputs and outputs directly at the machine level via a high-performance CANopen fieldbus interface. This compact Fieldbus Box module features 4 digital inputs with a 3 ms input filter alongside 4 digital outputs rated for 0.5 A, housing them within an IP67-rated enclosure designed to bypass the need for protective control cabinets. Connection is established using space-saving M8 connector sockets, minimizing cabling overhead and reducing transmission latency in decentralized automation topologies.

Features

  • Direct integration into CANopen industrial networks via standard D-sub or M12 connection interfaces.
  • Robust IP67 housing design, rendering the unit fully resistant to dust, moisture, and high-pressure washdown environments.
  • Four integrated 24 V DC digital inputs featuring an integrated 3 ms hardware input filter to suppress signal contact bounce.
  • Four short-circuit proof 24 V DC digital outputs capable of delivering up to 0.5 A continuous current per channel.
  • Diagnostic LEDs mapping network activity, device operational status, and localized channel diagnostics.
  • Simple rotary address switches for rapid node address configuration during commissioning.

Applications

  • Automotive assembly lines and robotic tool-end I/O processing.
  • Conveyor networks and packaging machinery requiring decentralized, machine-mount sensor consolidation.
  • Material handling plants utilizing distributed CANopen topologies.
  • Machine tool control lines subject to high coolant, oil, or particulate exposure.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Identifier IP2300-B510
Fieldbus System CANopen
Digital Inputs 4 channels (24 V DC)
Input Filter Time 3.0 ms
Digital Outputs 4 channels (24 V DC, short-circuit proof)
Max. Output Current 0.5 A per channel (total current limits apply)
I/O Connection Type M8 (diameter 8 mm circular connectors)
Operating Voltage 24 V DC (control and load voltage feeds)
Ingress Protection Rating IP67 (when all slots are mated or capped)
Operating Temperature Range 0 to 55 degC
Storage Temperature Range -25 to 85 degC
Shipping Weight (Calculated) 2.0 kg
Package Dimensions (Calculated) 220 mm x 110 mm x 60 mm

Connections and Interfaces

M8 Connector Pin Input Port Assignment Output Port Assignment
Pin 1 +24 V DC Sensor Supply Not Connected
Pin 2 Not Connected Auxiliary Ground Reference
Pin 3 GND Sensor Supply GND Load Supply
Pin 4 Digital Input Signal (DI1 to DI4) Digital Output Signal (DO1 to DO4)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2300-B510 utilizes standard CANopen communication profiles. While mechanically identical to the IP2300-B310 (PROFIBUS DP) and IP2300-B900 (Ethernet), it requires a dedicated CANopen master or coupler to map PDOs/SDOs. If migrating from older legacy Beckhoff Fieldbus Box units, verify your network master's ESD (electronic data sheet) configuration files to ensure parameter mappings match the device profile.

Application Pitfalls & Engineering Notes

When deploying in wet or high-humidity environments, any unused M8 ports must be covered using IP67-rated protective caps. Leaving even a single port exposed compromises the environmental seal of the entire assembly, leading to moisture ingress and localized internal short circuits between the 24 V DC sensor supply line and ground.

Commissioning & Wiring Tips

Ensure that the CANopen network is terminated with a 120-Ohm resistor at both ends of the physical bus. If the IP2300-B510 is configured as the physical end-of-line node, a dedicated terminating M12 plug must be inserted. Always set the node ID via the address dial switches under the protective screw cap prior to powering on the control logic feed.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources (logic and field power loops) before mounting, cabling, or adjusting the address switches. Ground loops can induce network dropouts and permanently degrade the integrated output transistors.

1
Mount the IP2300-B510 module directly onto a flat, vibration-resistant machine frame using M4 mounting screws. Connect the chassis ground contact to the machine frame.
2
Set the designated CANopen node address and communication baud rate using the rotary switches under the front protective cover. Reseal the cover tightly.
3
Attach the M8 sensor and actuator cables, ensuring a secure thread lock is achieved on each connector to protect against moisture intrusion.
4
Connect the incoming CANopen network cable and power lines. Turn on the 24 V DC system logic and perform testing sequences via your PLC's network master.
Loading product navigation…

What fieldbus protocol does the IP2300-B510 module utilize?

The IP2300-B510 operates using the CANopen communication protocol, allowing integration into standard CAN networks with flexible baud rate configurations.

What is the ingress protection rating of the IP2300-B510 box?

It is rated IP67, making it completely dust-tight and resistant to water immersion, provided all unused M8 and M12 connection ports are properly sealed with protective caps.

Can I output more than 0.5 A from the digital output channels?

No, the digital outputs are rated for a maximum of 0.5 A per channel. Drawing more current will trigger the integrated short-circuit protection mechanism.

How are the device nodes and communication speed set?

The CANopen node ID and baud rate parameters are manually configured using rotary switches located underneath the protective front screw cap.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...