Description

The BECKHOFF IP2302-B730 is a compact Fieldbus Box designed for decentralized industrial automation applications. As part of the robust IP2302 series, this device integrates digital input and digital output channels within a durable machine-mount housing, allowing direct installation in harsh industrial environments without requiring a control cabinet. It establishes communication via a Modbus fieldbus interface and operates on a standard 24 V DC industrial supply.

Engineered for modular machine and plant construction, the unit connects local sensors and actuators directly to the controller network. The decentralized IP67 construction protects internal circuitry against dust, moisture, and mechanical stress, supporting reliable signal acquisition and actuation directly at the process level.

Features

  • Decentralized Fieldbus Box design with IP67 protection for cabinet-free machine mounting
  • Integrated digital input and digital output channel configuration
  • Modbus communication interface for network integration
  • Standard 24 V DC industrial operating voltage supply
  • M12 connection technology for secure sensor and actuator cabling

Applications

  • Decentralized signal collection and actuator control in modular machine building
  • Conveyor and material handling systems exposed to workshop environments
  • Automated assembly and handling machinery requiring distributed I/O nodes
  • Industrial plant engineering where cabinet space is limited

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2302-B730
Product Type Fieldbus Box
Country of Origin Germany

Electrical

Parameter Specification
Nominal Voltage 24 V DC
Output Current per Channel 0.5 A

Signal and I/O

Parameter Specification
Digital Inputs 4 channels
Digital Outputs 4 channels
Filter / Response Time 3 ms

Communication

Parameter Specification
Fieldbus Protocol Modbus

Connection

Parameter Specification
Connection Technology M12

Installation Guidelines

  1. Verify that the exact model number (IP2302-B730) matches your system design requirements and network specifications.
  2. Ensure all power supplies and fieldbus lines are completely de-energized before beginning mechanical mounting or electrical wiring.
  3. Mount the Fieldbus Box securely onto a flat, stable machine surface using appropriate mounting hardware, maintaining proper clearance for M12 cable connectors.
  4. Inspect all M12 sensor, actuator, power, and fieldbus cables for damage before connecting them to the corresponding ports.
  5. Verify the 24 V DC supply polarity and voltage levels before restoring power to the system.
  6. Power on the unit and check the diagnostic LED indicators to confirm proper operational status and network communication.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the BECKHOFF IP2302-B730?
The BECKHOFF IP2302-B730 is a decentralized Fieldbus Box equipped with 4 digital input channels, 4 digital output channels, and a Modbus communication interface for industrial automation environments.
What communication protocol does the BECKHOFF IP2302-B730 use?
The BECKHOFF IP2302-B730 communicates via the Modbus protocol, enabling seamless integration into compatible fieldbus networks.
What power supply and connection type does the BECKHOFF IP2302-B730 require?
The BECKHOFF IP2302-B730 operates on a standard 24 V DC power supply and utilizes M12 connection technology for robust field wiring.
How many I/O channels are available on the BECKHOFF IP2302-B730?
The BECKHOFF IP2302-B730 features a total of 8 channels, consisting of 4 digital inputs and 4 digital outputs with a 0.5 A rating per output channel.
Reviews

IP2302-B730

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2302-B730 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2302-B730

  • Country of origin:Germany

  • Product Type: Fieldbus Box

  • Payment: T/T, Western Union

  • Weight: 420g

  • Dimensions: 12.6 x 3.0 x 5.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2302-B730 is a compact Fieldbus Box designed for decentralized industrial automation applications. As part of the robust IP2302 series, this device integrates digital input and digital output channels within a durable machine-mount housing, allowing direct installation in harsh industrial environments without requiring a control cabinet. It establishes communication via a Modbus fieldbus interface and operates on a standard 24 V DC industrial supply.

Engineered for modular machine and plant construction, the unit connects local sensors and actuators directly to the controller network. The decentralized IP67 construction protects internal circuitry against dust, moisture, and mechanical stress, supporting reliable signal acquisition and actuation directly at the process level.

Features

  • Decentralized Fieldbus Box design with IP67 protection for cabinet-free machine mounting
  • Integrated digital input and digital output channel configuration
  • Modbus communication interface for network integration
  • Standard 24 V DC industrial operating voltage supply
  • M12 connection technology for secure sensor and actuator cabling

Applications

  • Decentralized signal collection and actuator control in modular machine building
  • Conveyor and material handling systems exposed to workshop environments
  • Automated assembly and handling machinery requiring distributed I/O nodes
  • Industrial plant engineering where cabinet space is limited

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2302-B730
Product Type Fieldbus Box
Country of Origin Germany

Electrical

Parameter Specification
Nominal Voltage 24 V DC
Output Current per Channel 0.5 A

Signal and I/O

Parameter Specification
Digital Inputs 4 channels
Digital Outputs 4 channels
Filter / Response Time 3 ms

Communication

Parameter Specification
Fieldbus Protocol Modbus

Connection

Parameter Specification
Connection Technology M12

Installation Guidelines

  1. Verify that the exact model number (IP2302-B730) matches your system design requirements and network specifications.
  2. Ensure all power supplies and fieldbus lines are completely de-energized before beginning mechanical mounting or electrical wiring.
  3. Mount the Fieldbus Box securely onto a flat, stable machine surface using appropriate mounting hardware, maintaining proper clearance for M12 cable connectors.
  4. Inspect all M12 sensor, actuator, power, and fieldbus cables for damage before connecting them to the corresponding ports.
  5. Verify the 24 V DC supply polarity and voltage levels before restoring power to the system.
  6. Power on the unit and check the diagnostic LED indicators to confirm proper operational status and network communication.
Loading product navigation…

What is the BECKHOFF IP2302-B730?

The BECKHOFF IP2302-B730 is a decentralized Fieldbus Box equipped with 4 digital input channels, 4 digital output channels, and a Modbus communication interface for industrial automation environments.

What communication protocol does the BECKHOFF IP2302-B730 use?

The BECKHOFF IP2302-B730 communicates via the Modbus protocol, enabling seamless integration into compatible fieldbus networks.

What power supply and connection type does the BECKHOFF IP2302-B730 require?

The BECKHOFF IP2302-B730 operates on a standard 24 V DC power supply and utilizes M12 connection technology for robust field wiring.

How many I/O channels are available on the BECKHOFF IP2302-B730?

The BECKHOFF IP2302-B730 features a total of 8 channels, consisting of 4 digital inputs and 4 digital outputs with a 0.5 A rating per output channel.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors in different ways. This comparison covers torque quality, speed range, reversal, braking, electrical noise, thermal behavior, feedback, and retrofit...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controllable AC from a DC bus through semiconductor switching and filtering. This guide explains H-bridges, PWM, harmonics, motor loads, protection, thermal limits,...

Robot Force Control: From Contact Detection to Stable Process

Force control lets a robot adapt to contact instead of following position alone. This guide compares sensing approaches, control modes, process limits, safety boundaries, commissioning tests, and...

When Sensor-Level Logic Helps—and When It Hides Risk

Configurable sensors can perform window, latch, delay, and Boolean decisions before data reaches a PLC. The benefit is faster local behavior; the risk is hidden logic, weak diagnostics, and...

Connecting GX Simulator to Factory I/O Through OPC

A stable Mitsubishi virtual commissioning setup requires more than matching addresses. This guide explains the GX Simulator–OPC–Factory I/O data path, namespace design, scan timing, validation, and...