The BECKHOFF IP2320-B400 is a decentralized, IP67-rated Fieldbus Box designed for space-saving, machine-mounted application without a control cabinet. This combination I/O module integrates 4 digital inputs and 4 digital outputs within a single rugged enclosure, directly interfacing with Interbus industrial communication networks.

By bringing control signals directly to the machine frame, the BECKHOFF IP2320-B400 simplifies field wiring and reduces cabling complexity. Input signals are processed with a 3 ms filter time, while high-capacity digital outputs deliver up to 2 A per channel, making this module highly suitable for switching solenoids, valves, actuators, and other demanding load types in industrial automation environments.

Features

  • Interbus fieldbus interface for direct integration into decentralized control networks.
  • 4 digital inputs (24 V DC) with a 3 ms input filter.
  • 4 high-capacity digital outputs (24 V DC) rated at 2 A per channel.
  • Compact M8 (Ø8 mm) circular connection system for efficient, secure sensor and actuator wiring.
  • Durable IP67 protection class, safeguarding electronics against dust, moisture, and liquid ingress.
  • Localized diagnostic capability to facilitate rapid troubleshooting on the plant floor.

Applications

  • Decentralized machine control architectures where direct I/O mounting is required.
  • Material handling systems, packaging machinery, and conveyor networks.
  • Automated assembly and production lines utilizing Interbus communication.
  • High-current switching applications for valves, actuators, and contactors.

Technical Specifications

General

Manufacturer BECKHOFF
Model IP2320-B400
Product Type Fieldbus Box (I/O Combination Module)
Enclosure Protection Class IP67

Fieldbus and Communication

Fieldbus Interface Interbus

Digital Inputs

Number of Inputs 4
Nominal Voltage 24 V DC
Input Filter Time 3 ms

Digital Outputs

Number of Outputs 4
Nominal Voltage 24 V DC
Max. Output Current 2 A per channel

Connection and Wiring

I/O Connection Technology M8 (Ø8 mm circular connectors)

Connections / Interfaces

Interface Function
Interbus Interface Incoming and outgoing fieldbus communication lines
I/O Connectors (M8) 4 x Digital Input, 4 x Digital Output connections
Power Supply Connection Control voltage and load supply (24 V DC)

Installation Guidelines

  1. Verify that the physical model number matches IP2320-B400 before beginning installation.
  2. Ensure all system power supplies (fieldbus power, control power, and load power) are de-energized before mounting.
  3. Mount the Fieldbus Box securely onto a flat machine surface using the designated mounting holes. Do not overtighten mounting screws to avoid stress on the housing.
  4. Connect the incoming and outgoing Interbus lines using verified industrial-grade cabling.
  5. Wire sensors and actuators to the M8 circular ports. Ensure connectors are tightened to the appropriate hand-tight torque specification to maintain the IP67 environmental seal.
  6. Apply 24 V DC power and confirm logic/bus LED indicators illuminate correctly.
  7. Perform configuration and physical addressing within your Interbus master controller configuration software.

Replacement Recommendations

When replacing an existing BECKHOFF IP2320-B400, carefully label each M8 connector corresponding to its physical I/O channel before removal. Ensure the replacement unit is secured tightly to maintain vibration resistance, and verify that cable seals are undamaged to prevent moisture penetration.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2320-B400?
The BECKHOFF IP2320-B400 is an IP67-rated decentralized Fieldbus Box designed to connect 4 digital inputs and 4 high-current digital outputs directly to an Interbus network without requiring a control cabinet.
What connection system is used for I/O on the IP2320-B400?
The BECKHOFF IP2320-B400 utilizes M8 (Ø8 mm) circular connectors for quick and space-efficient connection of standard digital sensors and actuators.
What is the maximum output current supported by the IP2320-B400?
Each of the 4 digital outputs on the BECKHOFF IP2320-B400 is rated to switch load currents up to a maximum of 2 A.
Is a protective control cabinet necessary to install this Fieldbus Box?
No, the BECKHOFF IP2320-B400 is designed with an IP67 environmental protection rating, allowing it to be mounted directly to machinery in harsh environments without an electrical cabinet.
Reviews

IP2320-B400

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2320-B400 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2320-B400

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF IP2320-B400 is a decentralized, IP67-rated Fieldbus Box designed for space-saving, machine-mounted application without a control cabinet. This combination I/O module integrates 4 digital inputs and 4 digital outputs within a single rugged enclosure, directly interfacing with Interbus industrial communication networks.

By bringing control signals directly to the machine frame, the BECKHOFF IP2320-B400 simplifies field wiring and reduces cabling complexity. Input signals are processed with a 3 ms filter time, while high-capacity digital outputs deliver up to 2 A per channel, making this module highly suitable for switching solenoids, valves, actuators, and other demanding load types in industrial automation environments.

Features

  • Interbus fieldbus interface for direct integration into decentralized control networks.
  • 4 digital inputs (24 V DC) with a 3 ms input filter.
  • 4 high-capacity digital outputs (24 V DC) rated at 2 A per channel.
  • Compact M8 (Ø8 mm) circular connection system for efficient, secure sensor and actuator wiring.
  • Durable IP67 protection class, safeguarding electronics against dust, moisture, and liquid ingress.
  • Localized diagnostic capability to facilitate rapid troubleshooting on the plant floor.

Applications

  • Decentralized machine control architectures where direct I/O mounting is required.
  • Material handling systems, packaging machinery, and conveyor networks.
  • Automated assembly and production lines utilizing Interbus communication.
  • High-current switching applications for valves, actuators, and contactors.

Technical Specifications

General

Manufacturer BECKHOFF
Model IP2320-B400
Product Type Fieldbus Box (I/O Combination Module)
Enclosure Protection Class IP67

Fieldbus and Communication

Fieldbus Interface Interbus

Digital Inputs

Number of Inputs 4
Nominal Voltage 24 V DC
Input Filter Time 3 ms

Digital Outputs

Number of Outputs 4
Nominal Voltage 24 V DC
Max. Output Current 2 A per channel

Connection and Wiring

I/O Connection Technology M8 (Ø8 mm circular connectors)

Connections / Interfaces

Interface Function
Interbus Interface Incoming and outgoing fieldbus communication lines
I/O Connectors (M8) 4 x Digital Input, 4 x Digital Output connections
Power Supply Connection Control voltage and load supply (24 V DC)

Installation Guidelines

  1. Verify that the physical model number matches IP2320-B400 before beginning installation.
  2. Ensure all system power supplies (fieldbus power, control power, and load power) are de-energized before mounting.
  3. Mount the Fieldbus Box securely onto a flat machine surface using the designated mounting holes. Do not overtighten mounting screws to avoid stress on the housing.
  4. Connect the incoming and outgoing Interbus lines using verified industrial-grade cabling.
  5. Wire sensors and actuators to the M8 circular ports. Ensure connectors are tightened to the appropriate hand-tight torque specification to maintain the IP67 environmental seal.
  6. Apply 24 V DC power and confirm logic/bus LED indicators illuminate correctly.
  7. Perform configuration and physical addressing within your Interbus master controller configuration software.

Replacement Recommendations

When replacing an existing BECKHOFF IP2320-B400, carefully label each M8 connector corresponding to its physical I/O channel before removal. Ensure the replacement unit is secured tightly to maintain vibration resistance, and verify that cable seals are undamaged to prevent moisture penetration.

Loading product navigation…

What is the primary function of the BECKHOFF IP2320-B400?

The BECKHOFF IP2320-B400 is an IP67-rated decentralized Fieldbus Box designed to connect 4 digital inputs and 4 high-current digital outputs directly to an Interbus network without requiring a control cabinet.

What connection system is used for I/O on the IP2320-B400?

The BECKHOFF IP2320-B400 utilizes M8 (Ø8 mm) circular connectors for quick and space-efficient connection of standard digital sensors and actuators.

What is the maximum output current supported by the IP2320-B400?

Each of the 4 digital outputs on the BECKHOFF IP2320-B400 is rated to switch load currents up to a maximum of 2 A.

Is a protective control cabinet necessary to install this Fieldbus Box?

No, the BECKHOFF IP2320-B400 is designed with an IP67 environmental protection rating, allowing it to be mounted directly to machinery in harsh environments without an electrical cabinet.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...