Description

The BECKHOFF IP2321-B200 is a high-performance, decentralized Fieldbus Box designed to connect digital sensors and actuators directly to a Lightbus industrial network. By combining four digital inputs and four high-current digital outputs into a single module, this device provides space-efficient, distributed intelligence for modern control architectures.

Engineered for direct machine mounting, the BECKHOFF IP2321-B200 eliminates the requirement for protective control cabinets. The integrated B200 Lightbus interface provides rapid optical-fiber communication, ensuring high noise immunity and fast cycle times in demanding industrial environments.

Features

  • Standard Lightbus (B200) interface utilizing optical fiber connectors for reliable, noise-immune communication.
  • Four digital inputs with a 3 ms input filter to suppress signal bounce and electrical noise.
  • Four high-current digital outputs capable of switching up to 2 A per channel, suitable for solenoid valves and actuators.
  • Industry-standard M8 screw connectors for secure signal routing and rapid cabling.
  • Sealed, compact housing designed for direct installation on machinery and equipment.

Applications

  • Decentralized input and output data acquisition on packaging and assembly machinery.
  • Direct control of high-current pneumatic valves and solenoids without auxiliary relays.
  • Optical fiber communication setups requiring immunity to electromagnetic interference (EMI).

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model IP2321-B200
Product Type Fieldbus Box I/O Module
Fieldbus Connection Lightbus (B200) fiber optic
Number of Inputs 4 digital inputs (24 V DC)
Input Filter Time 3 ms
Number of Outputs 4 digital outputs (24 V DC)
Max. Output Current 2 A per channel
I/O Connection Method M8 screw connectors
Operating Voltage 24 V DC (control and load voltage)

Connections / Interfaces

Interface / Terminal Function
Lightbus IN / OUT Fiber optic connection for communication ring configuration
I/O Channels 1 - 4 Digital inputs via standard M8 connectors
I/O Channels 5 - 8 Digital outputs via standard M8 connectors
Power Supply 24 V DC connection for control electronics and actuator power

Installation Guidelines

  1. Ensure that the entire system power supply is de-energized and locked out before starting the installation process.
  2. Mount the BECKHOFF IP2321-B200 securely to the machine chassis using the integrated mounting holes.
  3. Inspect and clean the fiber optic connectors of the Lightbus cables prior to insertion to prevent signal attenuation.
  4. Connect the Lightbus fiber optic cables, verifying the correct physical ring topology (IN to OUT sequence).
  5. Thread and secure the M8 sensor and actuator cables, ensuring the connectors are hand-tightened to maintain environmental integrity.
  6. Apply the 24 V DC control and load voltages, then verify status indication indicators on the module during initial boot.

Replacement Recommendations

When replacing an existing BECKHOFF IP2321-B200 module, label all fiber optic and M8 connections to ensure exact relocation. Check fiber optic end-faces for dust or damage, cleaning them with specialized optical tools if necessary before insertion into the replacement unit.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2321-B200?
The BECKHOFF IP2321-B200 is a decentralized Fieldbus Box designed to connect 4 digital inputs (24 V DC) and 4 high-current digital outputs (2 A) directly to a Lightbus optical network without the need for an electrical cabinet.
What type of communication network does the BECKHOFF IP2321-B200 support?
The BECKHOFF IP2321-B200 communicates using the proprietary BECKHOFF Lightbus fiber-optic fieldbus system, which provides immunity to electromagnetic interference and fast communication cycles.
How are the physical sensor and actuator connections made on the BECKHOFF IP2321-B200?
The BECKHOFF IP2321-B200 uses industrial M8 screw connectors for all digital inputs and outputs, providing a highly reliable connection on the machine floor.
What is the maximum output current rating for the BECKHOFF IP2321-B200?
The BECKHOFF IP2321-B200 supports a maximum switching current of up to 2 A per digital output channel, allowing direct activation of larger actuators and valves.
Does the BECKHOFF IP2321-B200 require a protective control cabinet?
No, the BECKHOFF IP2321-B200 is housed in a sealed, moisture-resistant enclosure designed for direct mounting on machines, simplifying field wiring.
Reviews

IP2321-B200

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2321-B200 Lightbus Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2321-B200

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2321-B200 is a high-performance, decentralized Fieldbus Box designed to connect digital sensors and actuators directly to a Lightbus industrial network. By combining four digital inputs and four high-current digital outputs into a single module, this device provides space-efficient, distributed intelligence for modern control architectures.

Engineered for direct machine mounting, the BECKHOFF IP2321-B200 eliminates the requirement for protective control cabinets. The integrated B200 Lightbus interface provides rapid optical-fiber communication, ensuring high noise immunity and fast cycle times in demanding industrial environments.

Features

  • Standard Lightbus (B200) interface utilizing optical fiber connectors for reliable, noise-immune communication.
  • Four digital inputs with a 3 ms input filter to suppress signal bounce and electrical noise.
  • Four high-current digital outputs capable of switching up to 2 A per channel, suitable for solenoid valves and actuators.
  • Industry-standard M8 screw connectors for secure signal routing and rapid cabling.
  • Sealed, compact housing designed for direct installation on machinery and equipment.

Applications

  • Decentralized input and output data acquisition on packaging and assembly machinery.
  • Direct control of high-current pneumatic valves and solenoids without auxiliary relays.
  • Optical fiber communication setups requiring immunity to electromagnetic interference (EMI).

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model IP2321-B200
Product Type Fieldbus Box I/O Module
Fieldbus Connection Lightbus (B200) fiber optic
Number of Inputs 4 digital inputs (24 V DC)
Input Filter Time 3 ms
Number of Outputs 4 digital outputs (24 V DC)
Max. Output Current 2 A per channel
I/O Connection Method M8 screw connectors
Operating Voltage 24 V DC (control and load voltage)

Connections / Interfaces

Interface / Terminal Function
Lightbus IN / OUT Fiber optic connection for communication ring configuration
I/O Channels 1 - 4 Digital inputs via standard M8 connectors
I/O Channels 5 - 8 Digital outputs via standard M8 connectors
Power Supply 24 V DC connection for control electronics and actuator power

Installation Guidelines

  1. Ensure that the entire system power supply is de-energized and locked out before starting the installation process.
  2. Mount the BECKHOFF IP2321-B200 securely to the machine chassis using the integrated mounting holes.
  3. Inspect and clean the fiber optic connectors of the Lightbus cables prior to insertion to prevent signal attenuation.
  4. Connect the Lightbus fiber optic cables, verifying the correct physical ring topology (IN to OUT sequence).
  5. Thread and secure the M8 sensor and actuator cables, ensuring the connectors are hand-tightened to maintain environmental integrity.
  6. Apply the 24 V DC control and load voltages, then verify status indication indicators on the module during initial boot.

Replacement Recommendations

When replacing an existing BECKHOFF IP2321-B200 module, label all fiber optic and M8 connections to ensure exact relocation. Check fiber optic end-faces for dust or damage, cleaning them with specialized optical tools if necessary before insertion into the replacement unit.

Loading product navigation…

What is the primary function of the BECKHOFF IP2321-B200?

The BECKHOFF IP2321-B200 is a decentralized Fieldbus Box designed to connect 4 digital inputs (24 V DC) and 4 high-current digital outputs (2 A) directly to a Lightbus optical network without the need for an electrical cabinet.

What type of communication network does the BECKHOFF IP2321-B200 support?

The BECKHOFF IP2321-B200 communicates using the proprietary BECKHOFF Lightbus fiber-optic fieldbus system, which provides immunity to electromagnetic interference and fast communication cycles.

How are the physical sensor and actuator connections made on the BECKHOFF IP2321-B200?

The BECKHOFF IP2321-B200 uses industrial M8 screw connectors for all digital inputs and outputs, providing a highly reliable connection on the machine floor.

What is the maximum output current rating for the BECKHOFF IP2321-B200?

The BECKHOFF IP2321-B200 supports a maximum switching current of up to 2 A per digital output channel, allowing direct activation of larger actuators and valves.

Does the BECKHOFF IP2321-B200 require a protective control cabinet?

No, the BECKHOFF IP2321-B200 is housed in a sealed, moisture-resistant enclosure designed for direct mounting on machines, simplifying field wiring.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...