BECKHOFF

Beckhoff IP2311-B200 Fieldbus Box Digital I/O Module

SKU IP2311-B200

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: IP2311-B200

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 250g

  • Dimensions: 30 mm x 210 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Beckhoff IP2311-B200 is a high-performance, distributed Lightbus fieldbus box designed to bridge local digital sensors and actuators with centralized control systems. This ruggedized I/O module integrates 4 digital inputs and 4 digital outputs within a compact, direct-to-machine mountable enclosure, eliminating the need for a separate protective control cabinet.

Operating over the proprietary Beckhoff Lightbus protocol, the module utilizes plastic optical fiber (APF) to guarantee high-speed, noise-immune communication. This fiber-optic medium ensures complete electrical isolation between the communication network and the field power, making the IP2311-B200 exceptionally resilient in high-EMC industrial environments. Designed for direct field deployment, its fully encapsulated housing carries IP65/66/67 ratings, offering robust resistance to dust, moisture, and mechanical vibration.

Features

  • 4 digital inputs (24 V DC) with a 0.2 ms hardware input filter.
  • 4 short-circuit proof digital outputs rated at 0.5 A per channel.
  • Direct Lightbus network integration using plastic optical fiber (APF).
  • Highly secure, interference-free data transmission up to 45 meters between stations.
  • M8 screw-type connectors for standard sensor and actuator connections.
  • Compact and light PA6 polyamide housing with a robust physical design.
  • Comprehensive status LEDs for local diagnostics, channel activity, and optical link status.

Applications

  • Distributed packaging machinery and materials handling systems.
  • Automotive manufacturing lines demanding high EMC immunity.
  • Water and wastewater treatment facilities with high moisture exposure.
  • Machine tool and robotic assembly cells where cabinet space is limited.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model IP2311-B200
Fieldbus Interface Lightbus (2 x fiber-optic sockets for ZS1020-0010 plugs)
Data Transfer Rate 2.5 Mbaud
Transmission Medium APF (plastic) optical fiber (1000 micrometers)
Distance Between Stations Up to 45 m
Number of Channels 4 inputs + 4 outputs
Digital Inputs 24 V DC, -3 to +5 V ("0" signal), 11 to 30 V ("1" signal, 6 mA, Type 2)
Input Filter Time 0.2 ms
Digital Outputs 24 V DC (-15% / +20%), 0.5 A per channel, short-circuit proof
Load Types Supported Ohmic, inductive, lamp load
Control/Supply Voltage 24 V DC (-15% / +20%) via M8 connector
Electrical Isolation Control voltage to fieldbus: Yes
Enclosure Material PA6 (polyamide)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight Approx. 250 g

Installation Guidelines

  • Mounting: Mount the unit directly to the machine frame or flat surface using the 2 pre-drilled 3.5 mm mounting holes designed for M3 screws.
  • Fiber-Optic Handling: Maintain the specified minimum bending radius of the APF optical fiber cables to prevent signal attenuation and physical damage.
  • Tightening Torque: Ensure M8 sensor and power connectors are tightened to the recommended torque specification to preserve the IP67 protection rating.
  • Grounding: Connect the functional ground (FE) connection to a low-impedance ground point on the machine to ensure stable internal reference potential.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27

FAQ

What network interface does the Beckhoff IP2311-B200 use?

The IP2311-B200 connects to the Beckhoff Lightbus system using plastic optical fiber (APF) at a transfer rate of 2.5 Mbaud.

What is the maximum distance supported between two fieldbus boxes?

The maximum distance supported between two individual stations is 45 meters using plastic optical fiber (1000 micrometers).

Can this module be mounted directly onto a machine frame without a cabinet?

Yes. The module features an IP65/IP66/IP67 rated PA6 polyamide housing, making it highly resistant to dust, liquids, and vibration, suitable for direct machine installation.

What are the electrical ratings for the digital outputs?

The digital outputs support 24 V DC with a maximum load current of 0.5 A per channel. Each output channel is individually short-circuit proof.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.