1 of 1

Beckhoff IP3112-B518 Fieldbus Box

Beckhoff IP3112-B518 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP3112-B518

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Decentralized automation tasks require rugged hardware capable of operating outside traditional control cabinets. The Beckhoff IP3112-B518 Fieldbus Box meets this demand by providing direct connection of peripheral signals to CANopen networks in harsh industrial environments. By housing the communication and I/O interface in a compact, environmentally sealed module, this device minimizes cabling effort and reduces cabinet space requirements.

Operating as a high-performance CANopen node, the IP3112-B518 supports up to 16 send and 16 receive Process Data Objects (PDOs), enabling highly flexible data transmission. It features advanced CANopen communication profiles including life guarding, node guarding, emergency object handling, variable mapping, and store/restore parameters. Configuration can be executed either via the KS2000 service software or directly from the master controller using Service Data Objects (SDOs). The integrated M12 T-connector simplifies bus cabling by allowing direct loop-through of the network medium without additional external splitters.

Features

  • Direct integration into CANopen industrial networks.
  • Supports up to 16 send and 16 receive Process Data Objects (PDOs) for flexible data mapping.
  • Automatic detection of network data transfer rates from 10 kbaud up to 1 Mbaud.
  • Robust environmental protection class IP65, IP66, and IP67, enabling cabinet-free mounting.
  • Integrated M12 T-connector interface for efficient bus wiring and daisy-chaining.
  • Comprehensive diagnostics via built-in node guarding, life guarding, and emergency object services.

Applications

  • Automotive manufacturing and assembly lines.
  • Material handling systems and industrial conveyors.
  • Wastewater treatment facilities.
  • Food processing and packaging machinery.
  • Distributed sensor/actuator networks in heavy machine manufacturing.

Technical Specifications

Manufacturer Beckhoff
Model/Part Number IP3112-B518
Product Type CANopen Fieldbus Box
Data Transfer Rates 10 kbaud to 1 Mbaud (automatic detection)
Number of PDOs 16 send / 16 receive
Bus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated T-connector
Power Supply (Control) 24 V DC (-15 percent / +20 percent)
Power Supply Connections Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Electrical Isolation 500 V (control voltage / fieldbus)
Communication Modes Event-driven, cyclic, synchronous, polling
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Approximate Weight 2.0 kg (including shipping packaging)

Connections and Interfaces

Connection Type Interface Style Function
Bus Interface (Inlet) M12 Plug, 5-pin Incoming CANopen signal and bus power reference
Bus Interface (Outlet) M12 Socket, 5-pin Outgoing loop-through CANopen signal (integrated T-connector)
Power Feed M8 Male, 4-pin Control voltage supply (24 V DC)
Power Downstream M8 Female, 4-pin Power distribution to downstream Fieldbus Boxes

Installation Guidelines

  • Ensure the unit is mounted on a flat, vibration-resistant surface using the designated mounting holes.
  • Tighten all unused M12 and M8 connection ports with verified protective caps to maintain the IP67 sealing integrity.
  • Route bus lines and power cables separately from high-voltage motor or drive cabling to avoid electromagnetic interference.
  • Ensure correct termination of the CANopen network by installing a 120-Ohm terminating resistor at both physical ends of the bus segment.

Compliance and Certifications

  • CE
  • UL

What is the primary function of the Beckhoff IP3112-B518?

The Beckhoff IP3112-B518 is a decentralized CANopen Fieldbus Box designed to connect digital or analog I/O peripheral signals directly to a CANopen network without requiring an electrical control cabinet.

What is the protection rating of this module and where can it be installed?

The module features an IP65/66/67 rating conforming to EN 60529, allowing it to be installed directly on machines in wet, dusty, or highly demanding industrial environments.

How are the bus connections and power configured on the IP3112-B518?

It uses an integrated M12 T-connector (1 x 5-pin plug and 1 x 5-pin socket) for the CANopen bus connection, and M8 connectors (1 x 4-pin male feed, 1 x 4-pin female downstream) for power supply routing.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Micro Drive Specialist EMS Bets on Custom Engineering to Broaden Market Appeal

UK micro-drive specialist EMS is pairing Faulhaber high-torque gearheads and compact motion controllers with in-house custom engineering—aiming beyond catalog sales into tailored mechatronics.

Bringing Object-Oriented Thinking to PLC Programming

Copy-paste ladder does not scale. Object-oriented PLC techniques—user-defined structures and instructions—cut duplication, propagate fixes once, and keep large multi-device programs readable.

Why Process Safety Management Programs Fail Even When OSHA Boxes Are Checked

OSHA boxes checked is not the same as a living PSM system. Refinery history shows programs fail when procedures, training, contractors, and investigations drift from how the plant actually runs.

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.