BECKHOFF

BECKHOFF IP5109-B528 DeviceNet Fieldbus Box

SKU IP5109-B528

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP5109-B528
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Dimensions: 2 x 2 x 0.25 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF IP5109-B528 is a fieldbus-level communication module designed for direct mounting on machinery and equipment. Utilizing the DeviceNet protocol, this Fieldbus Box allows for highly distributed control layouts, collecting and transmitting peripheral signals directly at the machine site without requiring a protective control cabinet.

The BECKHOFF IP5109-B528 features integrated physical connections, utilizing an M12 plug and socket arrangement with an integrated tee-connector to simplify network topology. Transmission rates are detected automatically up to a maximum of 500 kbaud, matching the configured speed of the local DeviceNet segment. Electrical isolation of 500 V between the control logic and the fieldbus network ensures safe, stable signal transfer even in electrically noisy industrial environments.

Power delivery is split into distinct paths to maintain operational security, with control and load voltages configured via M8 supply connectors. Highly durable and protective housings make this device suitable for wet, dusty, or mechanically demanding environments, providing reliable signal integration directly at the point of action.

Features

  • DeviceNet network communication with automatic transmission rate detection up to 500 kbaud
  • Integrated physical bus interface consisting of one M12 plug (5-pin) and one M12 socket (5-pin) featuring a built-in tee-connector
  • Separate 24 V DC control voltage input and load voltage supply lines to isolate logical operations from field loads
  • Flexible I/O communication options, supporting polling, bit strobe, cyclic, and change-of-state modes
  • Direct machine mounting capability supported by a highly protective IP65, IP66, and IP67-rated enclosure
  • Configuration options using the KS2000 software interface or direct controller-level explicit messaging

Applications

  • Decentralized signal processing in high-moisture or washdown-heavy environments
  • Distributed machinery architectures using DeviceNet fieldbus topologies
  • Modular production lines requiring on-machine mounting without external electrical enclosures

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP5109-B528
Product Type Fieldbus Box
Configuration Option Via KS2000 software or the controller (explicit messaging)

Fieldbus and Communication

Parameter Specification
Fieldbus Protocol DeviceNet
Data Transfer Rates Automatic detection up to 500 kbaud
Bus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin), integrated tee-connector
Data Transfer Medium Shielded copper cable, with power supply, typically 2 x 2 x 0.25 mm²
I/O Communication Types Bit strobe, polling, cyclic, change of state

Electrical Data

Parameter Specification
Control Voltage Supply 24 V DC (-15% / +20%)
Load Voltage Supply According to I/O type
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + sensor current consumption (maximum 0.5 A)
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage to fieldbus: 500 V; Control voltage to inputs/outputs: according to I/O type

Environmental and Mechanical

Parameter Specification
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Approvals and Markings CE, UL

Installation Guidelines

  1. Ensure that all power sources (control and load voltages) are completely de-energized before mounting, wiring, or servicing the unit.
  2. Inspect the physical housing of the device for any structural damage before installation.
  3. Mount the module securely on a flat machine surface using the designated mounting holes. Variable orientation is permitted.
  4. Connect the DeviceNet network cabling to the M12 connectors, ensuring the integrated tee-connector configuration matches your network loop requirements.
  5. Connect the 24 V DC control power and downstream power loop via the integrated 4-pin M8 connectors, paying close attention to correct pin assignments.
  6. Ensure all unused M12 and M8 ports are sealed with appropriate protective caps to maintain the IP65/66/67 environmental protection rating.
  7. Perform configuration tasks using the KS2000 tool or direct explicit messaging via your master controller.

Replacement Recommendations

When replacing an existing unit with a new BECKHOFF IP5109-B528, record all physical wiring connections, device node addressing, and network baud rate configurations beforehand. Switch off all control and load power supplies. Swap the physical unit and reconnect the M12 and M8 cables, securing the connections tightly to preserve environmental sealing. Verify node configuration and run system checks to confirm correct network communication and status led behaviors before resuming automated operations.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What fieldbus protocol does the BECKHOFF IP5109-B528 support?
The BECKHOFF IP5109-B528 supports the DeviceNet fieldbus protocol, offering automatic data transfer rate detection up to a maximum of 500 kbaud.
How is the BECKHOFF IP5109-B528 module configured?
The BECKHOFF IP5109-B528 can be configured using either the BECKHOFF KS2000 configuration software or directly through the main controller using explicit messaging.
What are the physical network interfaces on the BECKHOFF IP5109-B528?
The BECKHOFF IP5109-B528 is equipped with one 5-pin M12 plug and one 5-pin M12 socket, which feature an integrated tee-connector for bus-looping applications.
Can the BECKHOFF IP5109-B528 be mounted directly on a machine?
Yes, the BECKHOFF IP5109-B528 features a protective housing rated to IP65, IP66, and IP67, allowing it to be mounted directly on machines in wet or dusty environments without a protective control panel.
What are the power connection requirements for the BECKHOFF IP5109-B528?
The BECKHOFF IP5109-B528 utilizes a 4-pin M8 male socket for incoming power feed and a 4-pin M8 female socket for downstream power loops, operating on a 24 V DC control voltage supply.
Reviews

IP5109-B528

Stock & lead time on request

Call
1 of 1

BECKHOFF IP5109-B528 DeviceNet Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP5109-B528

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 2 x 2 x 0.25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP5109-B528 is a fieldbus-level communication module designed for direct mounting on machinery and equipment. Utilizing the DeviceNet protocol, this Fieldbus Box allows for highly distributed control layouts, collecting and transmitting peripheral signals directly at the machine site without requiring a protective control cabinet.

The BECKHOFF IP5109-B528 features integrated physical connections, utilizing an M12 plug and socket arrangement with an integrated tee-connector to simplify network topology. Transmission rates are detected automatically up to a maximum of 500 kbaud, matching the configured speed of the local DeviceNet segment. Electrical isolation of 500 V between the control logic and the fieldbus network ensures safe, stable signal transfer even in electrically noisy industrial environments.

Power delivery is split into distinct paths to maintain operational security, with control and load voltages configured via M8 supply connectors. Highly durable and protective housings make this device suitable for wet, dusty, or mechanically demanding environments, providing reliable signal integration directly at the point of action.

Features

  • DeviceNet network communication with automatic transmission rate detection up to 500 kbaud
  • Integrated physical bus interface consisting of one M12 plug (5-pin) and one M12 socket (5-pin) featuring a built-in tee-connector
  • Separate 24 V DC control voltage input and load voltage supply lines to isolate logical operations from field loads
  • Flexible I/O communication options, supporting polling, bit strobe, cyclic, and change-of-state modes
  • Direct machine mounting capability supported by a highly protective IP65, IP66, and IP67-rated enclosure
  • Configuration options using the KS2000 software interface or direct controller-level explicit messaging

Applications

  • Decentralized signal processing in high-moisture or washdown-heavy environments
  • Distributed machinery architectures using DeviceNet fieldbus topologies
  • Modular production lines requiring on-machine mounting without external electrical enclosures

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP5109-B528
Product Type Fieldbus Box
Configuration Option Via KS2000 software or the controller (explicit messaging)

Fieldbus and Communication

Parameter Specification
Fieldbus Protocol DeviceNet
Data Transfer Rates Automatic detection up to 500 kbaud
Bus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin), integrated tee-connector
Data Transfer Medium Shielded copper cable, with power supply, typically 2 x 2 x 0.25 mm²
I/O Communication Types Bit strobe, polling, cyclic, change of state

Electrical Data

Parameter Specification
Control Voltage Supply 24 V DC (-15% / +20%)
Load Voltage Supply According to I/O type
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + sensor current consumption (maximum 0.5 A)
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage to fieldbus: 500 V; Control voltage to inputs/outputs: according to I/O type

Environmental and Mechanical

Parameter Specification
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Approvals and Markings CE, UL

Installation Guidelines

  1. Ensure that all power sources (control and load voltages) are completely de-energized before mounting, wiring, or servicing the unit.
  2. Inspect the physical housing of the device for any structural damage before installation.
  3. Mount the module securely on a flat machine surface using the designated mounting holes. Variable orientation is permitted.
  4. Connect the DeviceNet network cabling to the M12 connectors, ensuring the integrated tee-connector configuration matches your network loop requirements.
  5. Connect the 24 V DC control power and downstream power loop via the integrated 4-pin M8 connectors, paying close attention to correct pin assignments.
  6. Ensure all unused M12 and M8 ports are sealed with appropriate protective caps to maintain the IP65/66/67 environmental protection rating.
  7. Perform configuration tasks using the KS2000 tool or direct explicit messaging via your master controller.

Replacement Recommendations

When replacing an existing unit with a new BECKHOFF IP5109-B528, record all physical wiring connections, device node addressing, and network baud rate configurations beforehand. Switch off all control and load power supplies. Swap the physical unit and reconnect the M12 and M8 cables, securing the connections tightly to preserve environmental sealing. Verify node configuration and run system checks to confirm correct network communication and status led behaviors before resuming automated operations.

Loading product navigation…

What fieldbus protocol does the BECKHOFF IP5109-B528 support?

The BECKHOFF IP5109-B528 supports the DeviceNet fieldbus protocol, offering automatic data transfer rate detection up to a maximum of 500 kbaud.

How is the BECKHOFF IP5109-B528 module configured?

The BECKHOFF IP5109-B528 can be configured using either the BECKHOFF KS2000 configuration software or directly through the main controller using explicit messaging.

What are the physical network interfaces on the BECKHOFF IP5109-B528?

The BECKHOFF IP5109-B528 is equipped with one 5-pin M12 plug and one 5-pin M12 socket, which feature an integrated tee-connector for bus-looping applications.

Can the BECKHOFF IP5109-B528 be mounted directly on a machine?

Yes, the BECKHOFF IP5109-B528 features a protective housing rated to IP65, IP66, and IP67, allowing it to be mounted directly on machines in wet or dusty environments without a protective control panel.

What are the power connection requirements for the BECKHOFF IP5109-B528?

The BECKHOFF IP5109-B528 utilizes a 4-pin M8 male socket for incoming power feed and a 4-pin M8 female socket for downstream power loops, operating on a 24 V DC control voltage supply.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...