Description

The BECKHOFF IP2022-B510 is a high-performance decentralised Fieldbus Box designed to connect digital actuators directly within CANopen network architectures. By facilitating direct machine mounting without an enclosure, this module simplifies field-level wiring and minimises control cabinet space requirements. It features 8 digital outputs that operate at 24 V DC, providing dependable control for valves, contactors, indicators, and small motor loads in industrial settings.

Engineered for harsh industrial environments, the BECKHOFF IP2022-B510 features a rugged polyamide housing offering IP65, IP66, or IP67 protection. It communicates via CANopen using a standard 5-pin M12 connector and supports automatic baud rate detection up to 1 Mbaud. The load and control voltages are supplied via compact M8 connections with downstream loop-through capabilities, facilitating efficient daisy-chain power distribution across multiple modules.

Features

  • 8-channel digital output interface for direct field actuator control.
  • CANopen protocol compatibility with automatic baud rate detection from 10 kbaud up to 1 Mbaud.
  • High switching capability providing up to 2 A per channel (maximum 4 A total sum current).
  • Individually short-circuit proof outputs to protect field cabling and equipment.
  • Robust IP65/66/67 protection class allowing direct mounting on machinery without protective cabinets.
  • Integrated diagnostic monitoring and status LED indicators for rapid troubleshooting.
  • Efficient power distribution using M8 feed and downstream loop-through connectors.

Applications

  • Decentralised pneumatic and hydraulic valve control on manufacturing machinery.
  • Conveyor systems and material handling systems requiring local actuator switching.
  • Distributed packaging machinery and assembly line automation setups.
  • Direct machine-mount digital output expansions where control cabinet space is constrained.

Technical Specifications

General

Manufacturer BECKHOFF
Model IP2022-B510
Product Type Fieldbus Box
Housing Material PA6 (Polyamide)
Installation / Mounting 2 fixing holes, 3.5 mm diameter (for M3 screws)

Digital Outputs

Number of Outputs 8
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 2 A per channel (individually short-circuit proof)
Total Max. Output Current (Sum) 4 A
Load Type Ohmic, inductive, lamp load
Short-Circuit Current Max. 4 A
Auxiliary Power Current Typically 30 mA per channel

CANopen Communication

Fieldbus Protocol CANopen
Data Transfer Rates Automatic detection: 10 kbaud up to 1 Mbaud
Bus Interface Connection 1 x M12 plug, 5-pin
Process Image Bit Width 8 outputs
CANopen Features Life/Node guarding, emergency object, variable mapping, store/restore configuration
Configuration Interface Via KS2000 software tool or the system controller (SDOs)

Electrical & Isolation

Control Voltage Power Supply 24 V DC (-15 % / +20 %)
Box Supply Current 45 mA + sensor/auxiliary current (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V; channels/control voltage: no
Power Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin

Mechanical & Environmental

Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Vibration & Shock Resistance Conforms to EN 60068-2-6 & EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 & EN 61000-6-4
Approvals CE, UL

Connections / Interfaces

Interface / Connector Function / Description
M12 Bus Interface (5-pin Plug) CANopen network interface connection. Supports standard CAN wiring.
M12 Output Connectors (Screw Type) Connection points for the 8 digital outputs to field-level actuators.
M8 Power Supply Feed (4-pin Male) Main power connection input for control and load voltage supplies.
M8 Power Supply Downstream (4-pin Female) Loop-through connector to pass control and load voltages to adjacent Fieldbus Boxes.

Installation Guidelines

  1. Verify System State: Ensure all electrical power sources are switched off and locked out before initiating installation or maintenance tasks.
  2. Mounting: Securely install the module using the two 3.5 mm diameter fixing holes with suitable M3 screws on a flat surface or machine framework. Mounting orientation is variable.
  3. Fieldbus Connection: Connect the CANopen bus line to the 5-pin M12 bus interface plug, adhering to proper CAN shielding and termination practices.
  4. I/O Connections: Wire the actuators to the digital output M12 screw connections. Ensure the current draw does not exceed 2 A per individual channel and 4 A total.
  5. Power Wiring: Connect the 24 V DC power feed to the M8 male socket. If using downstream modules, daisy-chain the power from the downstream M8 female socket.
  6. Commissioning: Apply power, configure the CANopen node address and baud rate via the controller interface or KS2000 software, and verify status via the integrated diagnostic LEDs.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2022-B510?
The BECKHOFF IP2022-B510 is an 8-channel digital output CANopen Fieldbus Box designed to connect and control local field actuators directly on machinery, bypassing the need for protective electrical enclosures due to its IP67-rated construction.
What are the maximum current capabilities of the digital outputs on the BECKHOFF IP2022-B510?
The BECKHOFF IP2022-B510 digital outputs can switch up to 2 A per individual channel. However, the cumulative sum current of all channels combined must not exceed a maximum of 4 A.
How is the power distribution handled on the BECKHOFF IP2022-B510?
The BECKHOFF IP2022-B510 uses M8 power connections: one 4-pin male socket for the initial power feed and one 4-pin female socket to downstream loop-through power to adjacent Fieldbus Box modules, saving local wiring effort.
What protection standards does the BECKHOFF IP2022-B510 housing meet?
The BECKHOFF IP2022-B510 is built using a polyamide (PA6) housing that conforms to the IP65, IP66, and IP67 protection standards, ensuring reliable operation in dusty, damp, and wet industrial environments.
Does the BECKHOFF IP2022-B510 support electrical isolation?
The BECKHOFF IP2022-B510 provides 500 V of electrical isolation between the control voltage and the fieldbus interface. No isolation is present between the individual digital output channels or between the channels and the control voltage.
Reviews

IP2022-B510

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2022-B510 CANopen Fieldbus Box 8-Channel Digital Output

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2022-B510

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 30 mm x 175 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF IP2022-B510 is a high-performance decentralised Fieldbus Box designed to connect digital actuators directly within CANopen network architectures. By facilitating direct machine mounting without an enclosure, this module simplifies field-level wiring and minimises control cabinet space requirements. It features 8 digital outputs that operate at 24 V DC, providing dependable control for valves, contactors, indicators, and small motor loads in industrial settings.

Engineered for harsh industrial environments, the BECKHOFF IP2022-B510 features a rugged polyamide housing offering IP65, IP66, or IP67 protection. It communicates via CANopen using a standard 5-pin M12 connector and supports automatic baud rate detection up to 1 Mbaud. The load and control voltages are supplied via compact M8 connections with downstream loop-through capabilities, facilitating efficient daisy-chain power distribution across multiple modules.

Features

  • 8-channel digital output interface for direct field actuator control.
  • CANopen protocol compatibility with automatic baud rate detection from 10 kbaud up to 1 Mbaud.
  • High switching capability providing up to 2 A per channel (maximum 4 A total sum current).
  • Individually short-circuit proof outputs to protect field cabling and equipment.
  • Robust IP65/66/67 protection class allowing direct mounting on machinery without protective cabinets.
  • Integrated diagnostic monitoring and status LED indicators for rapid troubleshooting.
  • Efficient power distribution using M8 feed and downstream loop-through connectors.

Applications

  • Decentralised pneumatic and hydraulic valve control on manufacturing machinery.
  • Conveyor systems and material handling systems requiring local actuator switching.
  • Distributed packaging machinery and assembly line automation setups.
  • Direct machine-mount digital output expansions where control cabinet space is constrained.

Technical Specifications

General

Manufacturer BECKHOFF
Model IP2022-B510
Product Type Fieldbus Box
Housing Material PA6 (Polyamide)
Installation / Mounting 2 fixing holes, 3.5 mm diameter (for M3 screws)

Digital Outputs

Number of Outputs 8
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 2 A per channel (individually short-circuit proof)
Total Max. Output Current (Sum) 4 A
Load Type Ohmic, inductive, lamp load
Short-Circuit Current Max. 4 A
Auxiliary Power Current Typically 30 mA per channel

CANopen Communication

Fieldbus Protocol CANopen
Data Transfer Rates Automatic detection: 10 kbaud up to 1 Mbaud
Bus Interface Connection 1 x M12 plug, 5-pin
Process Image Bit Width 8 outputs
CANopen Features Life/Node guarding, emergency object, variable mapping, store/restore configuration
Configuration Interface Via KS2000 software tool or the system controller (SDOs)

Electrical & Isolation

Control Voltage Power Supply 24 V DC (-15 % / +20 %)
Box Supply Current 45 mA + sensor/auxiliary current (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V; channels/control voltage: no
Power Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin

Mechanical & Environmental

Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Vibration & Shock Resistance Conforms to EN 60068-2-6 & EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 & EN 61000-6-4
Approvals CE, UL

Connections / Interfaces

Interface / Connector Function / Description
M12 Bus Interface (5-pin Plug) CANopen network interface connection. Supports standard CAN wiring.
M12 Output Connectors (Screw Type) Connection points for the 8 digital outputs to field-level actuators.
M8 Power Supply Feed (4-pin Male) Main power connection input for control and load voltage supplies.
M8 Power Supply Downstream (4-pin Female) Loop-through connector to pass control and load voltages to adjacent Fieldbus Boxes.

Installation Guidelines

  1. Verify System State: Ensure all electrical power sources are switched off and locked out before initiating installation or maintenance tasks.
  2. Mounting: Securely install the module using the two 3.5 mm diameter fixing holes with suitable M3 screws on a flat surface or machine framework. Mounting orientation is variable.
  3. Fieldbus Connection: Connect the CANopen bus line to the 5-pin M12 bus interface plug, adhering to proper CAN shielding and termination practices.
  4. I/O Connections: Wire the actuators to the digital output M12 screw connections. Ensure the current draw does not exceed 2 A per individual channel and 4 A total.
  5. Power Wiring: Connect the 24 V DC power feed to the M8 male socket. If using downstream modules, daisy-chain the power from the downstream M8 female socket.
  6. Commissioning: Apply power, configure the CANopen node address and baud rate via the controller interface or KS2000 software, and verify status via the integrated diagnostic LEDs.
Loading product navigation…

What is the primary function of the BECKHOFF IP2022-B510?

The BECKHOFF IP2022-B510 is an 8-channel digital output CANopen Fieldbus Box designed to connect and control local field actuators directly on machinery, bypassing the need for protective electrical enclosures due to its IP67-rated construction.

What are the maximum current capabilities of the digital outputs on the BECKHOFF IP2022-B510?

The BECKHOFF IP2022-B510 digital outputs can switch up to 2 A per individual channel. However, the cumulative sum current of all channels combined must not exceed a maximum of 4 A.

How is the power distribution handled on the BECKHOFF IP2022-B510?

The BECKHOFF IP2022-B510 uses M8 power connections: one 4-pin male socket for the initial power feed and one 4-pin female socket to downstream loop-through power to adjacent Fieldbus Box modules, saving local wiring effort.

What protection standards does the BECKHOFF IP2022-B510 housing meet?

The BECKHOFF IP2022-B510 is built using a polyamide (PA6) housing that conforms to the IP65, IP66, and IP67 protection standards, ensuring reliable operation in dusty, damp, and wet industrial environments.

Does the BECKHOFF IP2022-B510 support electrical isolation?

The BECKHOFF IP2022-B510 provides 500 V of electrical isolation between the control voltage and the fieldbus interface. No isolation is present between the individual digital output channels or between the channels and the control voltage.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...