BECKHOFF

BECKHOFF IP2022-B510 CANopen Fieldbus Box 8-Channel Digital Output

SKU IP2022-B510

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: IP2022-B510

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 30 mm x 175 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF IP2022-B510 is a high-performance decentralised Fieldbus Box designed to connect digital actuators directly within CANopen network architectures. By facilitating direct machine mounting without an enclosure, this module simplifies field-level wiring and minimises control cabinet space requirements. It features 8 digital outputs that operate at 24 V DC, providing dependable control for valves, contactors, indicators, and small motor loads in industrial settings.

Engineered for harsh industrial environments, the BECKHOFF IP2022-B510 features a rugged polyamide housing offering IP65, IP66, or IP67 protection. It communicates via CANopen using a standard 5-pin M12 connector and supports automatic baud rate detection up to 1 Mbaud. The load and control voltages are supplied via compact M8 connections with downstream loop-through capabilities, facilitating efficient daisy-chain power distribution across multiple modules.

Features

  • 8-channel digital output interface for direct field actuator control.
  • CANopen protocol compatibility with automatic baud rate detection from 10 kbaud up to 1 Mbaud.
  • High switching capability providing up to 2 A per channel (maximum 4 A total sum current).
  • Individually short-circuit proof outputs to protect field cabling and equipment.
  • Robust IP65/66/67 protection class allowing direct mounting on machinery without protective cabinets.
  • Integrated diagnostic monitoring and status LED indicators for rapid troubleshooting.
  • Efficient power distribution using M8 feed and downstream loop-through connectors.

Applications

  • Decentralised pneumatic and hydraulic valve control on manufacturing machinery.
  • Conveyor systems and material handling systems requiring local actuator switching.
  • Distributed packaging machinery and assembly line automation setups.
  • Direct machine-mount digital output expansions where control cabinet space is constrained.

Technical Specifications

General

Manufacturer BECKHOFF
Model IP2022-B510
Product Type Fieldbus Box
Housing Material PA6 (Polyamide)
Installation / Mounting 2 fixing holes, 3.5 mm diameter (for M3 screws)

Digital Outputs

Number of Outputs 8
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 2 A per channel (individually short-circuit proof)
Total Max. Output Current (Sum) 4 A
Load Type Ohmic, inductive, lamp load
Short-Circuit Current Max. 4 A
Auxiliary Power Current Typically 30 mA per channel

CANopen Communication

Fieldbus Protocol CANopen
Data Transfer Rates Automatic detection: 10 kbaud up to 1 Mbaud
Bus Interface Connection 1 x M12 plug, 5-pin
Process Image Bit Width 8 outputs
CANopen Features Life/Node guarding, emergency object, variable mapping, store/restore configuration
Configuration Interface Via KS2000 software tool or the system controller (SDOs)

Electrical & Isolation

Control Voltage Power Supply 24 V DC (-15 % / +20 %)
Box Supply Current 45 mA + sensor/auxiliary current (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V; channels/control voltage: no
Power Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin

Mechanical & Environmental

Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Vibration & Shock Resistance Conforms to EN 60068-2-6 & EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 & EN 61000-6-4
Approvals CE, UL

Connections / Interfaces

Interface / Connector Function / Description
M12 Bus Interface (5-pin Plug) CANopen network interface connection. Supports standard CAN wiring.
M12 Output Connectors (Screw Type) Connection points for the 8 digital outputs to field-level actuators.
M8 Power Supply Feed (4-pin Male) Main power connection input for control and load voltage supplies.
M8 Power Supply Downstream (4-pin Female) Loop-through connector to pass control and load voltages to adjacent Fieldbus Boxes.

Installation Guidelines

  1. Verify System State: Ensure all electrical power sources are switched off and locked out before initiating installation or maintenance tasks.
  2. Mounting: Securely install the module using the two 3.5 mm diameter fixing holes with suitable M3 screws on a flat surface or machine framework. Mounting orientation is variable.
  3. Fieldbus Connection: Connect the CANopen bus line to the 5-pin M12 bus interface plug, adhering to proper CAN shielding and termination practices.
  4. I/O Connections: Wire the actuators to the digital output M12 screw connections. Ensure the current draw does not exceed 2 A per individual channel and 4 A total.
  5. Power Wiring: Connect the 24 V DC power feed to the M8 male socket. If using downstream modules, daisy-chain the power from the downstream M8 female socket.
  6. Commissioning: Apply power, configure the CANopen node address and baud rate via the controller interface or KS2000 software, and verify status via the integrated diagnostic LEDs.

FAQ

What is the primary function of the BECKHOFF IP2022-B510?

The BECKHOFF IP2022-B510 is an 8-channel digital output CANopen Fieldbus Box designed to connect and control local field actuators directly on machinery, bypassing the need for protective electrical enclosures due to its IP67-rated construction.

What are the maximum current capabilities of the digital outputs on the BECKHOFF IP2022-B510?

The BECKHOFF IP2022-B510 digital outputs can switch up to 2 A per individual channel. However, the cumulative sum current of all channels combined must not exceed a maximum of 4 A.

How is the power distribution handled on the BECKHOFF IP2022-B510?

The BECKHOFF IP2022-B510 uses M8 power connections: one 4-pin male socket for the initial power feed and one 4-pin female socket to downstream loop-through power to adjacent Fieldbus Box modules, saving local wiring effort.

What protection standards does the BECKHOFF IP2022-B510 housing meet?

The BECKHOFF IP2022-B510 is built using a polyamide (PA6) housing that conforms to the IP65, IP66, and IP67 protection standards, ensuring reliable operation in dusty, damp, and wet industrial environments.

Does the BECKHOFF IP2022-B510 support electrical isolation?

The BECKHOFF IP2022-B510 provides 500 V of electrical isolation between the control voltage and the fieldbus interface. No isolation is present between the individual digital output channels or between the channels and the control voltage.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.