Engineered for high-speed, dynamic measurement tasks, the BECKHOFF KS3361 acts as a high-performance Bus Terminal designed for direct connection to strain gauges in full-bridge configurations. This unit processes analog bridge signals and delivers digitized measurement values to the supervisory control system via the K-bus. By integrating a rapid analog input and a dedicated trigger input, it provides precise capturing of transient mechanical loads, making it an ideal choice for precise force, pressure, and torque logging in diverse automation structures.

The KS3361 features an integrated high-speed data logger with a 32 kbyte internal memory buffer, enabling local buffering of high-frequency signal waveforms. Its pluggable wiring design level allows for rapid terminal exchange without disconnecting the field wiring, facilitating straightforward installation and minimizing system downtime during maintenance. Compatible with all standard industrial fieldbuses through Beckhoff Bus Couplers, this terminal ensures seamless integration across varied industrial communication protocols.

Features

  • Equipped with 1 analog input for strain gauge bridge connections and 1 dedicated trigger input.
  • Features high-speed data logger technology with 32 kbytes of internal memory for signal storage.
  • Offers highly flexible conversion times, configurable down to 10 microseconds in fast sampling mode.
  • Provides 14-bit plus sign resolution for precise digitizing of low-level sensor signals.
  • Pluggable connection design facilitates quick maintenance and secure wiring configuration.
  • Direct power supply routing through the K-bus simplifies cabinet power distribution.

Applications

  • Dynamic force and torque measurement in automated test benches.
  • High-speed industrial weighing and dosing applications.
  • Structural health monitoring and mechanical load evaluation in heavy machinery.
  • Press-fit and joining process supervision in automotive and assembly lines.

Technical Specifications

ManufacturerPart Number / ModelProduct TypeNumber of InputsPower SupplySignal Voltage (UIN)Internal ResistanceBridge Supply VoltageResolutionConversion TimeSampling RateMeasuring ErrorInternal MemoryK-Bus Current ConsumptionProcess Image Bit WidthOperating TemperatureStorage TemperatureRelative HumidityVibration and Shock ResistanceEMC Immunity and EmissionProtection RatingDimensions (L x W x H)Weight
BECKHOFF
KS3361
Bus Terminal (Pluggable Connection Level)
1 analog, 1 trigger
Via the K-bus
-16 to +16 mV / -20 to +20 mV
> 1 MOhm (UB)
5 V DC, max. 20 mA
14 bit + sign
< 100 us (configurable down to 10 us in fast sampling mode)
< 100 us (configurable down to 10 us in fast sampling mode)
< +/- 1% (relative to full scale value)
32 kbytes
Typ. 120 mA (external SG power supply) / Typ. 140 mA (internal SG power supply from terminal 4 x 350 Ohm)
Input/Output: 1 x 16 bit data (1 x 8 bit status, 1 x 8 bit control)
0 to +55 degC
-25 to +85 degC
95%, no condensation
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP20
68 mm x 12 mm x 100 mm
0.055 kg

Connections and Interfaces

Wiring MethodPluggable Wiring LevelSolid Conductor Cross-SectionStranded Conductor Cross-SectionFlexible Conductor Cross-SectionStripping Length
Connection Property Specification
Spring actuation by screwdriver
Compatible with KSxxxx series terminals
0.08 to 1.5 mm2 (AWG 28 to 16)
0.08 to 1.5 mm2 (AWG 28 to 16)
0.14 to 1.5 mm2 (AWG 26 to 16)
9 to 10 mm

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF KS3361?
The BECKHOFF KS3361 is a Bus Terminal designed for high-speed strain gauge analysis. It allows direct connection of full-bridge strain gauges to K-bus systems for accurate force, weight, and torque measurements.
What is the maximum sampling rate of this terminal?
The conversion time and sampling rate are configurable under 100 microseconds, reaching down to 10 microseconds when operated in the fast sampling mode.
Does the KS3361 feature pluggable terminal connections?
Yes, as part of the KSxxxx series, the KS3361 includes a pluggable wiring level that allows the housing to be replaced without disconnecting individual field wires.
What are the ATEX hazardous area classifications for the KS3361?
The terminal is certified under ATEX marking II 3 G Ex nA IIC T4 Gc for safe operation in Zone 2 hazardous environments.
What is the capacity of the onboard memory buffer?
The KS3361 contains an integrated 32 kbyte internal memory buffer used for localized logging of dynamic signal waveforms.
Reviews

KS3361

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF KS3361 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS3361

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 55g

  • Dimensions: 68 mm x 12 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Engineered for high-speed, dynamic measurement tasks, the BECKHOFF KS3361 acts as a high-performance Bus Terminal designed for direct connection to strain gauges in full-bridge configurations. This unit processes analog bridge signals and delivers digitized measurement values to the supervisory control system via the K-bus. By integrating a rapid analog input and a dedicated trigger input, it provides precise capturing of transient mechanical loads, making it an ideal choice for precise force, pressure, and torque logging in diverse automation structures.

The KS3361 features an integrated high-speed data logger with a 32 kbyte internal memory buffer, enabling local buffering of high-frequency signal waveforms. Its pluggable wiring design level allows for rapid terminal exchange without disconnecting the field wiring, facilitating straightforward installation and minimizing system downtime during maintenance. Compatible with all standard industrial fieldbuses through Beckhoff Bus Couplers, this terminal ensures seamless integration across varied industrial communication protocols.

Features

  • Equipped with 1 analog input for strain gauge bridge connections and 1 dedicated trigger input.
  • Features high-speed data logger technology with 32 kbytes of internal memory for signal storage.
  • Offers highly flexible conversion times, configurable down to 10 microseconds in fast sampling mode.
  • Provides 14-bit plus sign resolution for precise digitizing of low-level sensor signals.
  • Pluggable connection design facilitates quick maintenance and secure wiring configuration.
  • Direct power supply routing through the K-bus simplifies cabinet power distribution.

Applications

  • Dynamic force and torque measurement in automated test benches.
  • High-speed industrial weighing and dosing applications.
  • Structural health monitoring and mechanical load evaluation in heavy machinery.
  • Press-fit and joining process supervision in automotive and assembly lines.

Technical Specifications

ManufacturerPart Number / ModelProduct TypeNumber of InputsPower SupplySignal Voltage (UIN)Internal ResistanceBridge Supply VoltageResolutionConversion TimeSampling RateMeasuring ErrorInternal MemoryK-Bus Current ConsumptionProcess Image Bit WidthOperating TemperatureStorage TemperatureRelative HumidityVibration and Shock ResistanceEMC Immunity and EmissionProtection RatingDimensions (L x W x H)Weight
BECKHOFF
KS3361
Bus Terminal (Pluggable Connection Level)
1 analog, 1 trigger
Via the K-bus
-16 to +16 mV / -20 to +20 mV
> 1 MOhm (UB)
5 V DC, max. 20 mA
14 bit + sign
< 100 us (configurable down to 10 us in fast sampling mode)
< 100 us (configurable down to 10 us in fast sampling mode)
< +/- 1% (relative to full scale value)
32 kbytes
Typ. 120 mA (external SG power supply) / Typ. 140 mA (internal SG power supply from terminal 4 x 350 Ohm)
Input/Output: 1 x 16 bit data (1 x 8 bit status, 1 x 8 bit control)
0 to +55 degC
-25 to +85 degC
95%, no condensation
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP20
68 mm x 12 mm x 100 mm
0.055 kg

Connections and Interfaces

Wiring MethodPluggable Wiring LevelSolid Conductor Cross-SectionStranded Conductor Cross-SectionFlexible Conductor Cross-SectionStripping Length
Connection Property Specification
Spring actuation by screwdriver
Compatible with KSxxxx series terminals
0.08 to 1.5 mm2 (AWG 28 to 16)
0.08 to 1.5 mm2 (AWG 28 to 16)
0.14 to 1.5 mm2 (AWG 26 to 16)
9 to 10 mm

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
Key Features:

What is the primary function of the BECKHOFF KS3361?

The BECKHOFF KS3361 is a Bus Terminal designed for high-speed strain gauge analysis. It allows direct connection of full-bridge strain gauges to K-bus systems for accurate force, weight, and torque measurements.

What is the maximum sampling rate of this terminal?

The conversion time and sampling rate are configurable under 100 microseconds, reaching down to 10 microseconds when operated in the fast sampling mode.

Does the KS3361 feature pluggable terminal connections?

Yes, as part of the KSxxxx series, the KS3361 includes a pluggable wiring level that allows the housing to be replaced without disconnecting individual field wires.

What are the ATEX hazardous area classifications for the KS3361?

The terminal is certified under ATEX marking II 3 G Ex nA IIC T4 Gc for safe operation in Zone 2 hazardous environments.

What is the capacity of the onboard memory buffer?

The KS3361 contains an integrated 32 kbyte internal memory buffer used for localized logging of dynamic signal waveforms.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...