The KL2442 is a 2-channel digital output terminal designed for the Beckhoff Bus Terminal system. It is engineered to control 24 V DC actuators, such as ohmic, inductive, or lamp loads. Each channel provides a high current capacity of up to 4.0 A and is individually short-circuit proof. For demanding applications requiring higher power, the two channels can be connected in parallel to achieve a capacity of up to 8 A. The terminal uses a 3-wire connection technology and ensures robust isolation (500 V) between the K-bus and field potential.

Features

  • 2 digital output channels
  • High current capacity: 4.0 A per channel (8 A total in parallel)
  • 3-wire connection technology
  • Individual short-circuit protection
  • Reverse voltage protection for enhanced reliability
  • Compact DIN rail mounting

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Number of Outputs 2
Nominal Voltage 24 V DC (-15 %/+20 %)
Max. Output Current 4.0 A per channel (8 A parallel)
Short-Circuit Current < 70 A
E-bus/Field Isolation 500 V
Protection Rating IP20
Weight Approx. 70 g
Approvals CE

Installation Guidelines

  • Mounting: Secure the KL2442 onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism is engaged to maintain solid power contact.
  • Wiring: The 3-wire technology allows for direct connection of sensors/actuators. Ensure wire gauges are sufficient to handle the 4 A (or 8 A) load current safely.
  • Parallel Operation: If connecting channels in parallel to achieve 8 A capacity, ensure the load is balanced and the wiring layout is optimized to handle the increased current.
  • Safety: While channels are short-circuit proof, external fuses are recommended to protect the wiring and field power supply from sustained fault currents.
  • Environment: Maintain ambient temperatures between 0 degC and +55 degC and keep relative humidity below 95% (non-condensing) to prevent moisture buildup in the terminal housing.

FAQ

What is the maximum output current for the KL2442?

The terminal supports 4.0 A per channel, which can be increased to 8 A if the two channels are connected in parallel.

Does the KL2442 include short-circuit protection?

Yes, each channel is individually short-circuit proof.

What connection technology does this terminal use?

It uses 3-wire connection technology for the outputs.

Is the module reverse voltage protected?

Yes, the module includes reverse voltage protection.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
Germany
Power source
DC Power

Technical knowledge

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide