The KL2442 is a 2-channel digital output terminal designed for the Beckhoff Bus Terminal system. It is engineered to control 24 V DC actuators, such as ohmic, inductive, or lamp loads. Each channel provides a high current capacity of up to 4.0 A and is individually short-circuit proof. For demanding applications requiring higher power, the two channels can be connected in parallel to achieve a capacity of up to 8 A. The terminal uses a 3-wire connection technology and ensures robust isolation (500 V) between the K-bus and field potential.

Features

  • 2 digital output channels
  • High current capacity: 4.0 A per channel (8 A total in parallel)
  • 3-wire connection technology
  • Individual short-circuit protection
  • Reverse voltage protection for enhanced reliability
  • Compact DIN rail mounting

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Number of Outputs 2
Nominal Voltage 24 V DC (-15 %/+20 %)
Max. Output Current 4.0 A per channel (8 A parallel)
Short-Circuit Current < 70 A
E-bus/Field Isolation 500 V
Protection Rating IP20
Weight Approx. 70 g
Approvals CE

Installation Guidelines

  • Mounting: Secure the KL2442 onto a standard 35 mm DIN rail (EN 60715). Ensure the locking mechanism is engaged to maintain solid power contact.
  • Wiring: The 3-wire technology allows for direct connection of sensors/actuators. Ensure wire gauges are sufficient to handle the 4 A (or 8 A) load current safely.
  • Parallel Operation: If connecting channels in parallel to achieve 8 A capacity, ensure the load is balanced and the wiring layout is optimized to handle the increased current.
  • Safety: While channels are short-circuit proof, external fuses are recommended to protect the wiring and field power supply from sustained fault currents.
  • Environment: Maintain ambient temperatures between 0 degC and +55 degC and keep relative humidity below 95% (non-condensing) to prevent moisture buildup in the terminal housing.

FAQ

What is the maximum output current for the KL2442?

The terminal supports 4.0 A per channel, which can be increased to 8 A if the two channels are connected in parallel.

Does the KL2442 include short-circuit protection?

Yes, each channel is individually short-circuit proof.

What connection technology does this terminal use?

It uses 3-wire connection technology for the outputs.

Is the module reverse voltage protected?

Yes, the module includes reverse voltage protection.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
Germany
Power source
DC Power

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.