BECKHOFF

BECKHOFF KL6031 Bus Terminal

SKU KL6031

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: KL6031
  • Origin Germany
  • Product Type: Bus Terminals
  • Payment: T/T, Western Union
  • Weight: 0.08 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF KL6031 is an RS232 serial interface Bus Terminal designed to integrate serial communication devices directly into the Beckhoff Bus Coupler system. This terminal establishes a bidirectional, full-duplex transmission channel with dedicated transmit (TxD) and receive (RxD) signal lines. The serial interface operates independently of the higher-level fieldbus, providing a flexible interface path for serial devices such as scanners, barcode readers, local operator panels, weighing scales, and sensors.

To ensure robust operation in industrial environments, the BECKHOFF KL6031 features 500 V electrical isolation between the internal K-bus and the field-side RS232 signal lines. The terminal integrates a local hardware data buffer to prevent data loss, storing incoming and outgoing bytes before they are processed by the controller. Configuration, including baud rate and parity adjustments, is managed directly through the bus coupler or the central controller, removing the need for manual DIP switches or onboard adjustment dials.

Features

  • Full-duplex RS232 communication via dedicated TxD and RxD channels
  • Integrated hardware buffers containing a 1024-byte receive buffer and a 128-byte transmit buffer
  • 500 V electrical isolation between the K-bus logic and the RS232 signal circuits
  • Adjustable data transfer rates from 4800 to 115,200 baud (default setting: 9600 baud, 8 data bits, no parity, 1 stop bit)
  • High interference immunity for stable transmission over serial lines
  • Automatic address assignment with configuration handled entirely via the Bus Coupler or controller software

Applications

  • Interfacing barcode scanners, barcode readers, and RFID systems with central automation networks
  • Connecting legacy serial operator terminals and local human-machine interfaces (HMIs)
  • Integrating industrial scales, measuring instruments, and digital sensors using serial protocols
  • Connecting serial control devices, printers, and laboratory instrumentation to a central control system

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model KL6031
Product Type Bus Terminal

Electrical

Parameter Specification
Power Supply Via the K-bus
Current Consumption (K-bus) Typical 55 mA
Power Contacts Current None (no power contacts present)
Electrical Isolation 500 V (K-bus / signal voltage)

Serial Interface and Communication

Parameter Specification
Interface Technology RS232
Data Transfer Channels 2 (1 transmit, 1 receive), full duplex
Data Transfer Rates 4800 to 115,200 baud (default: 9600 baud, 8 data bits, no parity, 1 stop bit)
Bit Distortion Less than 3%
Cable Length Maximum 15 m
"0" Signal Voltage -18 V to -3 V
"1" Signal Voltage 3 V to 18 V
Receive Buffer 1024 bytes
Transmit Buffer 128 bytes
Process Image Bit Width Input/output: 22 x 8-bit user data, 2 x 8-bit control/status (up to 22 bytes of user data)

Mechanical and Environmental

Parameter Specification
Weight Approx. 80 g
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 95%, non-condensing
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Wiring Configuration Pluggable wiring for KSxxxx series models

Installation Guidelines

  1. Ensure that the entire automation system and the fieldbus node are completely de-energized before mounting, wiring, or removing the terminal.
  2. Mount the BECKHOFF KL6031 terminal on a standard 35 mm DIN rail (EN 60715) by snapping it onto the rail alongside the other Bus Terminals and Bus Couplers.
  3. Verify that the mechanical side-locking mechanism and the lateral K-bus contacts engage securely with the neighboring modules.
  4. Connect the RS232 field signal wires (TxD, RxD, and reference ground) to the terminal contacts. Ensure the use of high-quality, shielded cables to limit electromagnetic interference, and keep the total serial cable length under 15 meters.
  5. Verify that no power contact routing is connected to this terminal, as the unit is powered solely via the K-bus and does not feed or utilize structural power contacts.
  6. Apply power to the bus node and verify the status indicators. Configure transmission parameters (such as baud rate, stop bits, and parity) within the controller project or TwinCAT System Manager.

Compliance and Certifications

The BECKHOFF KL6031 complies with standard industrial guidelines and certifications, including CE, UL, ATEX, and DNV GL. It features the Ex marking: II 3 G Ex nA IIC T4 Gc, making it suitable for deployment in classified hazardous environments under specified operation conditions.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What serial transmission rates does the BECKHOFF KL6031 support?
The BECKHOFF KL6031 supports data transfer rates from 4800 to 115,200 baud, with a default factory setting of 9600 baud, 8 data bits, no parity, and 1 stop bit.
Does the BECKHOFF KL6031 require external field power connections?
No, the BECKHOFF KL6031 does not require field-side power connections or power contacts. It is powered internally via the K-bus, with a typical current consumption of 55 mA.
What is the maximum RS232 cable length for the BECKHOFF KL6031?
The BECKHOFF KL6031 serial interface is designed for a maximum cable length of 15 meters using shielded communication cables to maintain proper signal integrity.
How large are the data buffers on the BECKHOFF KL6031?
The BECKHOFF KL6031 contains a built-in 1024-byte receive buffer and a 128-byte transmit buffer to prevent data overrun during active serial transmission.
Is the BECKHOFF KL6031 electrically isolated from the K-bus?
Yes, the BECKHOFF KL6031 provides 500 V of electrical isolation between the internal K-bus and the signal/serial interface circuits to shield the system from electromagnetic interference.
Reviews

KL6031

Stock & lead time on request

Call
1 of 1

BECKHOFF KL6031 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL6031

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 80g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KL6031 is an RS232 serial interface Bus Terminal designed to integrate serial communication devices directly into the Beckhoff Bus Coupler system. This terminal establishes a bidirectional, full-duplex transmission channel with dedicated transmit (TxD) and receive (RxD) signal lines. The serial interface operates independently of the higher-level fieldbus, providing a flexible interface path for serial devices such as scanners, barcode readers, local operator panels, weighing scales, and sensors.

To ensure robust operation in industrial environments, the BECKHOFF KL6031 features 500 V electrical isolation between the internal K-bus and the field-side RS232 signal lines. The terminal integrates a local hardware data buffer to prevent data loss, storing incoming and outgoing bytes before they are processed by the controller. Configuration, including baud rate and parity adjustments, is managed directly through the bus coupler or the central controller, removing the need for manual DIP switches or onboard adjustment dials.

Features

  • Full-duplex RS232 communication via dedicated TxD and RxD channels
  • Integrated hardware buffers containing a 1024-byte receive buffer and a 128-byte transmit buffer
  • 500 V electrical isolation between the K-bus logic and the RS232 signal circuits
  • Adjustable data transfer rates from 4800 to 115,200 baud (default setting: 9600 baud, 8 data bits, no parity, 1 stop bit)
  • High interference immunity for stable transmission over serial lines
  • Automatic address assignment with configuration handled entirely via the Bus Coupler or controller software

Applications

  • Interfacing barcode scanners, barcode readers, and RFID systems with central automation networks
  • Connecting legacy serial operator terminals and local human-machine interfaces (HMIs)
  • Integrating industrial scales, measuring instruments, and digital sensors using serial protocols
  • Connecting serial control devices, printers, and laboratory instrumentation to a central control system

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model KL6031
Product Type Bus Terminal

Electrical

Parameter Specification
Power Supply Via the K-bus
Current Consumption (K-bus) Typical 55 mA
Power Contacts Current None (no power contacts present)
Electrical Isolation 500 V (K-bus / signal voltage)

Serial Interface and Communication

Parameter Specification
Interface Technology RS232
Data Transfer Channels 2 (1 transmit, 1 receive), full duplex
Data Transfer Rates 4800 to 115,200 baud (default: 9600 baud, 8 data bits, no parity, 1 stop bit)
Bit Distortion Less than 3%
Cable Length Maximum 15 m
"0" Signal Voltage -18 V to -3 V
"1" Signal Voltage 3 V to 18 V
Receive Buffer 1024 bytes
Transmit Buffer 128 bytes
Process Image Bit Width Input/output: 22 x 8-bit user data, 2 x 8-bit control/status (up to 22 bytes of user data)

Mechanical and Environmental

Parameter Specification
Weight Approx. 80 g
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 95%, non-condensing
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Wiring Configuration Pluggable wiring for KSxxxx series models

Installation Guidelines

  1. Ensure that the entire automation system and the fieldbus node are completely de-energized before mounting, wiring, or removing the terminal.
  2. Mount the BECKHOFF KL6031 terminal on a standard 35 mm DIN rail (EN 60715) by snapping it onto the rail alongside the other Bus Terminals and Bus Couplers.
  3. Verify that the mechanical side-locking mechanism and the lateral K-bus contacts engage securely with the neighboring modules.
  4. Connect the RS232 field signal wires (TxD, RxD, and reference ground) to the terminal contacts. Ensure the use of high-quality, shielded cables to limit electromagnetic interference, and keep the total serial cable length under 15 meters.
  5. Verify that no power contact routing is connected to this terminal, as the unit is powered solely via the K-bus and does not feed or utilize structural power contacts.
  6. Apply power to the bus node and verify the status indicators. Configure transmission parameters (such as baud rate, stop bits, and parity) within the controller project or TwinCAT System Manager.

Compliance and Certifications

The BECKHOFF KL6031 complies with standard industrial guidelines and certifications, including CE, UL, ATEX, and DNV GL. It features the Ex marking: II 3 G Ex nA IIC T4 Gc, making it suitable for deployment in classified hazardous environments under specified operation conditions.

Loading product navigation…

What serial transmission rates does the BECKHOFF KL6031 support?

The BECKHOFF KL6031 supports data transfer rates from 4800 to 115,200 baud, with a default factory setting of 9600 baud, 8 data bits, no parity, and 1 stop bit.

Does the BECKHOFF KL6031 require external field power connections?

No, the BECKHOFF KL6031 does not require field-side power connections or power contacts. It is powered internally via the K-bus, with a typical current consumption of 55 mA.

What is the maximum RS232 cable length for the BECKHOFF KL6031?

The BECKHOFF KL6031 serial interface is designed for a maximum cable length of 15 meters using shielded communication cables to maintain proper signal integrity.

How large are the data buffers on the BECKHOFF KL6031?

The BECKHOFF KL6031 contains a built-in 1024-byte receive buffer and a 128-byte transmit buffer to prevent data overrun during active serial transmission.

Is the BECKHOFF KL6031 electrically isolated from the K-bus?

Yes, the BECKHOFF KL6031 provides 500 V of electrical isolation between the internal K-bus and the signal/serial interface circuits to shield the system from electromagnetic interference.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...