Description

The BECKHOFF KL6224 is an IO-Link master Bus Terminal designed to integrate field-level IO-Link devices directly into the standard K-bus terminal system. Operating as a point-to-point interface, this terminal enables the integration of up to four IO-Link devices, including intelligent sensors, actuators, or specialty modules. This integration facilitates bidirectional communication, allowing the controller level to access process data, parameter configurations, and comprehensive diagnostic information.

Utilizing a compact 12 mm housing, the BECKHOFF KL6224 supports a 3-wire connection method for efficient field wiring. The terminal accommodates variable communication speeds and acts as a gateway between the field devices and the higher-level automation bus network. This enables predictive maintenance, parameter storage, and real-time device monitoring within standard K-bus configurations.

Features

  • Four independent IO-Link channels for connection of up to four IO-Link field devices
  • Full compliance with the IO-Link specification V1.1
  • Supports standard transmission rates of 4.8 kbaud, 38.4 kbaud, and 230.4 kbaud
  • 3-wire connection technology for straightforward wiring topologies
  • Standard 500 V electrical isolation between K-bus and signal voltage levels
  • Integral diagnostic status LEDs for individual channel monitoring
  • Saves cabinet space with a compact, DIN rail-mountable housing

Applications

  • Integration of intelligent sensors and actuators into K-bus control architectures
  • Automated parameters mapping and recipe distribution to field-level components
  • Machine diagnostic networks requiring device-specific health and error monitoring
  • Factory automation environments utilizing standardized IO-Link topologies

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model KL6224
Product Type Bus Terminal (IO-Link Master)
Number of Channels 4
Weight approx. 60 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Protection Class IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Electrical

Parameter Specification
Nominal Voltage 24 V DC (-15 % / +20 %)
Power Supply Via K-bus and power contacts
Current Consumption (K-bus) typ. 85 mA
Power Contacts Yes
Electrical Isolation 500 V (K-bus / signal voltage)

IO-Link and Communication

Parameter Specification
Specification Version IO-Link V1.1
Connection Method 3-wire
Data Transfer Rates 4.8 kbaud, 38.4 kbaud, and 230.4 kbaud
Cable Length max. 20 m

Installation Guidelines

  1. Ensure the power supply to the entire K-bus assembly is switched off before inserting or removing any terminal block.
  2. Inspect the BECKHOFF KL6224 for physical damage prior to installation on the mounting rail.
  3. Mount the terminal on a standard 35 mm DIN rail, pushing it firmly into place until the locking mechanism clicks securely.
  4. Align and lock the terminal into the adjacent Bus Terminals to ensure proper contact of K-bus interfaces and power contacts.
  5. Connect field cables to the designated terminal contact points using the proper 3-wire termination procedure. Do not exceed the maximum IO-Link cable length of 20 meters.
  6. Reapply power to the system and configure the master node settings using the appropriate engineering environment.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF KL6224?
The BECKHOFF KL6224 is a 4-channel IO-Link master Bus Terminal designed to integrate up to four IO-Link field devices directly into a standard K-bus control system.
Which IO-Link specification version does the BECKHOFF KL6224 support?
The BECKHOFF KL6224 supports the IO-Link V1.1 specification, enabling bidirectionality for process data, configuration parameters, and diagnostic communication.
What data transfer rates are supported by the BECKHOFF KL6224?
The BECKHOFF KL6224 supports three standard IO-Link transmission rates: 4.8 kbaud, 38.4 kbaud, and 230.4 kbaud.
What is the maximum cable distance for devices connected to the BECKHOFF KL6224?
The BECKHOFF KL6224 supports a maximum connection cable length of up to 20 meters between the terminal channel and each individual IO-Link device.
How is the BECKHOFF KL6224 powered?
The BECKHOFF KL6224 is powered internally via the standard K-bus (drawing typically 85 mA) and externally through the module's integrated 24 V DC power contacts.
Reviews

KL6224

Stock & lead time on request

Call
1 of 1

BECKHOFF KL6224 IO-Link Master Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL6224

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 60g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KL6224 is an IO-Link master Bus Terminal designed to integrate field-level IO-Link devices directly into the standard K-bus terminal system. Operating as a point-to-point interface, this terminal enables the integration of up to four IO-Link devices, including intelligent sensors, actuators, or specialty modules. This integration facilitates bidirectional communication, allowing the controller level to access process data, parameter configurations, and comprehensive diagnostic information.

Utilizing a compact 12 mm housing, the BECKHOFF KL6224 supports a 3-wire connection method for efficient field wiring. The terminal accommodates variable communication speeds and acts as a gateway between the field devices and the higher-level automation bus network. This enables predictive maintenance, parameter storage, and real-time device monitoring within standard K-bus configurations.

Features

  • Four independent IO-Link channels for connection of up to four IO-Link field devices
  • Full compliance with the IO-Link specification V1.1
  • Supports standard transmission rates of 4.8 kbaud, 38.4 kbaud, and 230.4 kbaud
  • 3-wire connection technology for straightforward wiring topologies
  • Standard 500 V electrical isolation between K-bus and signal voltage levels
  • Integral diagnostic status LEDs for individual channel monitoring
  • Saves cabinet space with a compact, DIN rail-mountable housing

Applications

  • Integration of intelligent sensors and actuators into K-bus control architectures
  • Automated parameters mapping and recipe distribution to field-level components
  • Machine diagnostic networks requiring device-specific health and error monitoring
  • Factory automation environments utilizing standardized IO-Link topologies

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model KL6224
Product Type Bus Terminal (IO-Link Master)
Number of Channels 4
Weight approx. 60 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
Protection Class IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Electrical

Parameter Specification
Nominal Voltage 24 V DC (-15 % / +20 %)
Power Supply Via K-bus and power contacts
Current Consumption (K-bus) typ. 85 mA
Power Contacts Yes
Electrical Isolation 500 V (K-bus / signal voltage)

IO-Link and Communication

Parameter Specification
Specification Version IO-Link V1.1
Connection Method 3-wire
Data Transfer Rates 4.8 kbaud, 38.4 kbaud, and 230.4 kbaud
Cable Length max. 20 m

Installation Guidelines

  1. Ensure the power supply to the entire K-bus assembly is switched off before inserting or removing any terminal block.
  2. Inspect the BECKHOFF KL6224 for physical damage prior to installation on the mounting rail.
  3. Mount the terminal on a standard 35 mm DIN rail, pushing it firmly into place until the locking mechanism clicks securely.
  4. Align and lock the terminal into the adjacent Bus Terminals to ensure proper contact of K-bus interfaces and power contacts.
  5. Connect field cables to the designated terminal contact points using the proper 3-wire termination procedure. Do not exceed the maximum IO-Link cable length of 20 meters.
  6. Reapply power to the system and configure the master node settings using the appropriate engineering environment.
Loading product navigation…

What is the primary function of the BECKHOFF KL6224?

The BECKHOFF KL6224 is a 4-channel IO-Link master Bus Terminal designed to integrate up to four IO-Link field devices directly into a standard K-bus control system.

Which IO-Link specification version does the BECKHOFF KL6224 support?

The BECKHOFF KL6224 supports the IO-Link V1.1 specification, enabling bidirectionality for process data, configuration parameters, and diagnostic communication.

What data transfer rates are supported by the BECKHOFF KL6224?

The BECKHOFF KL6224 supports three standard IO-Link transmission rates: 4.8 kbaud, 38.4 kbaud, and 230.4 kbaud.

What is the maximum cable distance for devices connected to the BECKHOFF KL6224?

The BECKHOFF KL6224 supports a maximum connection cable length of up to 20 meters between the terminal channel and each individual IO-Link device.

How is the BECKHOFF KL6224 powered?

The BECKHOFF KL6224 is powered internally via the standard K-bus (drawing typically 85 mA) and externally through the module's integrated 24 V DC power contacts.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...