BECKHOFF

BECKHOFF KM1008-0002 Bus Terminal Module

SKU KM1008-0002

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: KM1008-0002

  • Country of origin:Germany

  • Product Type: Bus Terminal Module

  • Payment: T/T, Western Union

  • Weight: 310g

  • Dimensions: 12.3 x 10 x 5.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF KM1008-0002 is a high-density Bus Terminal module featuring 64 digital inputs designed for industrial automation tasks. Engineered to interface binary 24 V DC control signals from sensors to higher-level automation systems via the K-bus, this compact terminal module provides extensive channel integration within a space-saving housing.

Signal connection is handled via a pluggable wiring level utilizing 1-wire connection technology complete with integrated status LEDs for each channel. The module processes standard type 1 signals in accordance with EN 61131-2 specifications, offering dependable data acquisition with a typical input filter of 3.0 ms.

Features

  • 64 digital input channels arranged in an 8 x 8 matrix configuration
  • Nominal input voltage of 24 V DC compliant with EN 61131-2, type 1 standards
  • Pluggable wiring level supporting 1-wire connection technology with integrated channel status LEDs
  • Typical input filter time of 3.0 ms for stable signal processing
  • Direct integration into the BECKHOFF K-bus system requiring no manual address or configuration settings
  • Electrical isolation of 500 V between the K-bus and field potential

Applications

  • High-density digital signal acquisition in modular machine building
  • Industrial control panels requiring concentrated I/O footprints
  • Factory automation systems utilizing BECKHOFF Bus Terminal architectures
  • Process monitoring and sensor data collection in 24 V DC environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KM1008-0002
Product Type Bus Terminal Module
Design Form Compact terminal module with pluggable wiring level
Configuration No address or configuration setting required
Country of Origin Germany

Signal and I/O

Parameter Specification
Number of Inputs 64 (8 x 8)
Nominal Voltage 24 V DC (-15 % / +20 %)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 15 to 30 V
Input Current Typ. 5 mA
Input Filter Typ. 3.0 ms
Bit Width in Process Image 64 inputs

Electrical

Parameter Specification
Current Consumption K-bus Typ. 3 mA
Current Consumption Power Contacts None (no power contacts)
Electrical Isolation 500 V (K-bus / field potential)

Connection

Parameter Specification
Connection Technology Plug (1-wire with LEDs)
Connection Cross-Section 0.08 to 1.5 mm² (stranded and solid wire)
Stripping Length 8 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 123 mm x 100 mm x 55 mm
Net Weight Approx. 310 g (with 1-pin connector) / approx. 390 g (with 3-pin connector)
Mounting On 35 mm DIN rail conforming to EN 60715 with lock
Side-by-Side Mounting By means of double slot and key connection
Protection Rating IP20
Installation Position Variable
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE

Installation Guidelines

  1. Ensure the entire control system is safely de-energized before beginning any mechanical or electrical installation work.
  2. Inspect the BECKHOFF KM1008-0002 module and connectors for any signs of transit damage.
  3. Mount the module onto a standard 35 mm DIN rail by engaging the locking mechanism in accordance with EN 60715.
  4. Secure adjacent modules using the integrated double slot and key connection system.
  5. Strip the connecting wires to the specified length of 8 mm, maintaining a conductor cross-section between 0.08 and 1.5 mm².
  6. Connect the field sensors to the pluggable 1-wire terminal points while verifying correct potential and signal assignment.
  7. Verify system bus connections and supply voltages before re-applying power and commissioning the station.

FAQ

How many digital inputs does the BECKHOFF KM1008-0002 support?

The BECKHOFF KM1008-0002 supports 64 digital input channels arranged in an 8 x 8 configuration.

What is the nominal input voltage for the BECKHOFF KM1008-0002?

The BECKHOFF KM1008-0002 operates at a nominal input voltage of 24 V DC, compliant with EN 61131-2, type 1 standards.

Does the BECKHOFF KM1008-0002 require manual address setting?

No, the BECKHOFF KM1008-0002 requires no manual address or configuration settings as it integrates directly into the K-bus system.

What type of connection technology is used on the BECKHOFF KM1008-0002?

The BECKHOFF KM1008-0002 utilizes a pluggable 1-wire connection technology equipped with integrated status LEDs for each input channel.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.