BECKHOFF

BECKHOFF KM1008-0002 Bus Terminal Module

SKU KM1008-0002

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: KM1008-0002
  • Origin Germany
  • Product Type: Bus Terminal Module
  • Payment: T/T, Western Union
  • Weight: 0.31 kg
  • Dimensions: 12.3 x 10 x 5.5 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF KM1008-0002 is a high-density Bus Terminal module featuring 64 digital inputs designed for industrial automation tasks. Engineered to interface binary 24 V DC control signals from sensors to higher-level automation systems via the K-bus, this compact terminal module provides extensive channel integration within a space-saving housing.

Signal connection is handled via a pluggable wiring level utilizing 1-wire connection technology complete with integrated status LEDs for each channel. The module processes standard type 1 signals in accordance with EN 61131-2 specifications, offering dependable data acquisition with a typical input filter of 3.0 ms.

Features

  • 64 digital input channels arranged in an 8 x 8 matrix configuration
  • Nominal input voltage of 24 V DC compliant with EN 61131-2, type 1 standards
  • Pluggable wiring level supporting 1-wire connection technology with integrated channel status LEDs
  • Typical input filter time of 3.0 ms for stable signal processing
  • Direct integration into the BECKHOFF K-bus system requiring no manual address or configuration settings
  • Electrical isolation of 500 V between the K-bus and field potential

Applications

  • High-density digital signal acquisition in modular machine building
  • Industrial control panels requiring concentrated I/O footprints
  • Factory automation systems utilizing BECKHOFF Bus Terminal architectures
  • Process monitoring and sensor data collection in 24 V DC environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KM1008-0002
Product Type Bus Terminal Module
Design Form Compact terminal module with pluggable wiring level
Configuration No address or configuration setting required
Country of Origin Germany

Signal and I/O

Parameter Specification
Number of Inputs 64 (8 x 8)
Nominal Voltage 24 V DC (-15 % / +20 %)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 15 to 30 V
Input Current Typ. 5 mA
Input Filter Typ. 3.0 ms
Bit Width in Process Image 64 inputs

Electrical

Parameter Specification
Current Consumption K-bus Typ. 3 mA
Current Consumption Power Contacts None (no power contacts)
Electrical Isolation 500 V (K-bus / field potential)

Connection

Parameter Specification
Connection Technology Plug (1-wire with LEDs)
Connection Cross-Section 0.08 to 1.5 mm² (stranded and solid wire)
Stripping Length 8 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 123 mm x 100 mm x 55 mm
Net Weight Approx. 310 g (with 1-pin connector) / approx. 390 g (with 3-pin connector)
Mounting On 35 mm DIN rail conforming to EN 60715 with lock
Side-by-Side Mounting By means of double slot and key connection
Protection Rating IP20
Installation Position Variable
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE

Installation Guidelines

  1. Ensure the entire control system is safely de-energized before beginning any mechanical or electrical installation work.
  2. Inspect the BECKHOFF KM1008-0002 module and connectors for any signs of transit damage.
  3. Mount the module onto a standard 35 mm DIN rail by engaging the locking mechanism in accordance with EN 60715.
  4. Secure adjacent modules using the integrated double slot and key connection system.
  5. Strip the connecting wires to the specified length of 8 mm, maintaining a conductor cross-section between 0.08 and 1.5 mm².
  6. Connect the field sensors to the pluggable 1-wire terminal points while verifying correct potential and signal assignment.
  7. Verify system bus connections and supply voltages before re-applying power and commissioning the station.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
How many digital inputs does the BECKHOFF KM1008-0002 support?
The BECKHOFF KM1008-0002 supports 64 digital input channels arranged in an 8 x 8 configuration.
What is the nominal input voltage for the BECKHOFF KM1008-0002?
The BECKHOFF KM1008-0002 operates at a nominal input voltage of 24 V DC, compliant with EN 61131-2, type 1 standards.
Does the BECKHOFF KM1008-0002 require manual address setting?
No, the BECKHOFF KM1008-0002 requires no manual address or configuration settings as it integrates directly into the K-bus system.
What type of connection technology is used on the BECKHOFF KM1008-0002?
The BECKHOFF KM1008-0002 utilizes a pluggable 1-wire connection technology equipped with integrated status LEDs for each input channel.
Reviews

KM1008-0002

Stock & lead time on request

Call
1 of 1

BECKHOFF KM1008-0002 Bus Terminal Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KM1008-0002

  • Country of origin:Germany

  • Product Type: Bus Terminal Module

  • Payment: T/T, Western Union

  • Weight: 310g

  • Dimensions: 12.3 x 10 x 5.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KM1008-0002 is a high-density Bus Terminal module featuring 64 digital inputs designed for industrial automation tasks. Engineered to interface binary 24 V DC control signals from sensors to higher-level automation systems via the K-bus, this compact terminal module provides extensive channel integration within a space-saving housing.

Signal connection is handled via a pluggable wiring level utilizing 1-wire connection technology complete with integrated status LEDs for each channel. The module processes standard type 1 signals in accordance with EN 61131-2 specifications, offering dependable data acquisition with a typical input filter of 3.0 ms.

Features

  • 64 digital input channels arranged in an 8 x 8 matrix configuration
  • Nominal input voltage of 24 V DC compliant with EN 61131-2, type 1 standards
  • Pluggable wiring level supporting 1-wire connection technology with integrated channel status LEDs
  • Typical input filter time of 3.0 ms for stable signal processing
  • Direct integration into the BECKHOFF K-bus system requiring no manual address or configuration settings
  • Electrical isolation of 500 V between the K-bus and field potential

Applications

  • High-density digital signal acquisition in modular machine building
  • Industrial control panels requiring concentrated I/O footprints
  • Factory automation systems utilizing BECKHOFF Bus Terminal architectures
  • Process monitoring and sensor data collection in 24 V DC environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KM1008-0002
Product Type Bus Terminal Module
Design Form Compact terminal module with pluggable wiring level
Configuration No address or configuration setting required
Country of Origin Germany

Signal and I/O

Parameter Specification
Number of Inputs 64 (8 x 8)
Nominal Voltage 24 V DC (-15 % / +20 %)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 15 to 30 V
Input Current Typ. 5 mA
Input Filter Typ. 3.0 ms
Bit Width in Process Image 64 inputs

Electrical

Parameter Specification
Current Consumption K-bus Typ. 3 mA
Current Consumption Power Contacts None (no power contacts)
Electrical Isolation 500 V (K-bus / field potential)

Connection

Parameter Specification
Connection Technology Plug (1-wire with LEDs)
Connection Cross-Section 0.08 to 1.5 mm² (stranded and solid wire)
Stripping Length 8 mm

Mechanical and Environmental

Parameter Specification
Dimensions (W x H x D) 123 mm x 100 mm x 55 mm
Net Weight Approx. 310 g (with 1-pin connector) / approx. 390 g (with 3-pin connector)
Mounting On 35 mm DIN rail conforming to EN 60715 with lock
Side-by-Side Mounting By means of double slot and key connection
Protection Rating IP20
Installation Position Variable
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE

Installation Guidelines

  1. Ensure the entire control system is safely de-energized before beginning any mechanical or electrical installation work.
  2. Inspect the BECKHOFF KM1008-0002 module and connectors for any signs of transit damage.
  3. Mount the module onto a standard 35 mm DIN rail by engaging the locking mechanism in accordance with EN 60715.
  4. Secure adjacent modules using the integrated double slot and key connection system.
  5. Strip the connecting wires to the specified length of 8 mm, maintaining a conductor cross-section between 0.08 and 1.5 mm².
  6. Connect the field sensors to the pluggable 1-wire terminal points while verifying correct potential and signal assignment.
  7. Verify system bus connections and supply voltages before re-applying power and commissioning the station.
Loading product navigation…

How many digital inputs does the BECKHOFF KM1008-0002 support?

The BECKHOFF KM1008-0002 supports 64 digital input channels arranged in an 8 x 8 configuration.

What is the nominal input voltage for the BECKHOFF KM1008-0002?

The BECKHOFF KM1008-0002 operates at a nominal input voltage of 24 V DC, compliant with EN 61131-2, type 1 standards.

Does the BECKHOFF KM1008-0002 require manual address setting?

No, the BECKHOFF KM1008-0002 requires no manual address or configuration settings as it integrates directly into the K-bus system.

What type of connection technology is used on the BECKHOFF KM1008-0002?

The BECKHOFF KM1008-0002 utilizes a pluggable 1-wire connection technology equipped with integrated status LEDs for each input channel.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors differently. Compare current ripple, low-speed torque, field control, feedback, reversing, braking energy, electromagnetic effects, and retrofit risks...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controlled AC from a DC bus, but reliable operation depends on PWM, motor control, cable effects, braking energy, thermal limits, protection, and commissioning across...

Robot Force Control: From Contact Detection to Stable Process

Robot force control adapts contact processes to real variation. This guide compares sensing methods and control modes, then explains tuning, safety boundaries, PLC integration, commissioning, and...