BECKHOFF

BECKHOFF KL6841 Bus Terminal

SKU KL6841

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: KL6841
  • Origin Germany
  • Product Type: Bus Terminals
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF KL6841 Bus Terminal is a specialized SMI (Standard Motor Interface) master terminal designed for integration into Beckhoff K-bus modular I/O systems. This single-channel terminal enables the direct connection and control of up to 16 SMI slaves, such as shutter and blind drives, via a standard two-wire line topology. Operating as a dedicated communication interface, the device manages data exchange at a transfer rate of 2400 baud over cable lengths of up to 200 meters, allowing precise positioning and status monitoring within building automation and industrial shading applications.

The terminal features integrated power management for the connected field devices, supporting an SMI system voltage of 230 V AC and a nominal input voltage of 24 V DC for internal electronics. Additionally, the KL6841 includes two onboard digital inputs intended to facilitate simplified local commissioning and manual override functions. Integration into the control system is handled via the higher-level Bus Coupler or controller, utilizing the dedicated TwinCAT PLC SMI library for streamlined engineering and parameterization.

Features

  • Single-channel SMI master interface for up to 16 Standard Motor Interface slaves
  • Supports line topology with a maximum cable length of 200 meters at 2400 baud
  • Integrated SMI system supply at 230 V AC for connected drives
  • Equipped with 2 digital inputs for simplified local commissioning
  • Process image bit width of 24 bytes for input and output data exchange
  • Robust electrical isolation between the SMI bus, K-bus, and power contacts
  • Configurable via the higher-level Bus Coupler or controller using TwinCAT PLC libraries

Applications

  • Building automation and commercial real estate management
  • Centralized and decentralized control of motorized blinds, roller shutters, and sun protection systems
  • Energy-efficient facade automation integrated into Beckhoff control architectures

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KL6841
Product Type Bus Terminal
Technology SMI (Standard Motor Interface)
Country of Origin Germany

Signal and I/O

Parameter Specification
Number of Channels 1
Number of Slaves Up to 16 SMI slaves
Digital Inputs 2 inputs for simplified commissioning
Bit Width in Process Image Input/output: 24 bytes

Electrical and Communication

Parameter Specification
Data Transfer Standard SMI
Data Transfer Rate 2400 baud
Topology Line topology
Max. Cable Length 200 m
Input Voltage 24 V DC (-15 % / +20 %)
SMI System Voltage 230 V AC
Current Consumption K-Bus Typ. 55 mA
Electrical Isolation 500 V (K-bus / SMI-bus)
Insulation Voltage SMI bus / K-bus: 1,500 V DC; SMI bus / power contacts: 1,500 V AC

Mechanical and Environmental

Parameter Specification
Weight Approx. 80 g
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Approvals CE

Installation Guidelines

  1. Ensure the entire control system is de-energized and locked out before beginning installation or wiring work.
  2. Inspect the BECKHOFF KL6841 Bus Terminal and its housing for any signs of transport damage.
  3. Mount the terminal onto the 35 mm DIN rail adjacent to the appropriate Bus Coupler or existing K-bus terminals, ensuring a secure mechanical lock.
  4. Verify that the K-bus connections and power contacts interlock correctly with neighboring modules.
  5. Connect the SMI line topology and field power supplies in accordance with the application wiring requirements, maintaining proper shielding and separation between low-voltage control circuits and the 230 V AC SMI network.
  6. Apply system power and verify operation using the diagnostic indicators and the TwinCAT software environment.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the BECKHOFF KL6841 Bus Terminal and how many devices can it control?
The BECKHOFF KL6841 Bus Terminal is a specialized single-channel SMI master terminal designed for integration into modular K-bus I/O systems. It enables the direct connection, precise positioning, and status monitoring of up to 16 Standard Motor Interface slaves, such as motorized blinds and roller shutters. The device uses a standard two-wire line topology to manage data exchange securely across your building automation network.
What are the communication specifications and limits for the BECKHOFF KL6841?
The BECKHOFF KL6841 operates using the Standard Motor Interface data transfer protocol at a fixed rate of 2400 baud. It supports a maximum cable length of up to 200 meters in a line topology configuration. Additionally, it features a process image bit width of 24 bytes for both input and output data exchange.
What power supplies does the BECKHOFF KL6841 require during operation?
The BECKHOFF KL6841 requires a nominal input voltage of 24 V DC to power its internal electronics, drawing a typical K-bus current consumption of 55 mA. For the field side, it incorporates an integrated SMI system supply voltage of 230 V AC to drive the connected motor slaves. Robust electrical isolation of up to 1,500 V DC ensures safe separation between the SMI bus, K-bus, and power contacts.
What is the purpose of the onboard digital inputs on the BECKHOFF KL6841?
The BECKHOFF KL6841 is equipped with two onboard digital inputs intended to facilitate simplified local commissioning and manual override functions. These inputs allow technicians to test and verify connected actuators directly on-site before executing final parameterization. Integration into the broader control system is handled seamlessly through higher-level Bus Couplers and the TwinCAT PLC SMI library.
Reviews

KL6841

Stock & lead time on request

Call
1 of 1

BECKHOFF KL6841 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL6841

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KL6841 Bus Terminal is a specialized SMI (Standard Motor Interface) master terminal designed for integration into Beckhoff K-bus modular I/O systems. This single-channel terminal enables the direct connection and control of up to 16 SMI slaves, such as shutter and blind drives, via a standard two-wire line topology. Operating as a dedicated communication interface, the device manages data exchange at a transfer rate of 2400 baud over cable lengths of up to 200 meters, allowing precise positioning and status monitoring within building automation and industrial shading applications.

The terminal features integrated power management for the connected field devices, supporting an SMI system voltage of 230 V AC and a nominal input voltage of 24 V DC for internal electronics. Additionally, the KL6841 includes two onboard digital inputs intended to facilitate simplified local commissioning and manual override functions. Integration into the control system is handled via the higher-level Bus Coupler or controller, utilizing the dedicated TwinCAT PLC SMI library for streamlined engineering and parameterization.

Features

  • Single-channel SMI master interface for up to 16 Standard Motor Interface slaves
  • Supports line topology with a maximum cable length of 200 meters at 2400 baud
  • Integrated SMI system supply at 230 V AC for connected drives
  • Equipped with 2 digital inputs for simplified local commissioning
  • Process image bit width of 24 bytes for input and output data exchange
  • Robust electrical isolation between the SMI bus, K-bus, and power contacts
  • Configurable via the higher-level Bus Coupler or controller using TwinCAT PLC libraries

Applications

  • Building automation and commercial real estate management
  • Centralized and decentralized control of motorized blinds, roller shutters, and sun protection systems
  • Energy-efficient facade automation integrated into Beckhoff control architectures

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KL6841
Product Type Bus Terminal
Technology SMI (Standard Motor Interface)
Country of Origin Germany

Signal and I/O

Parameter Specification
Number of Channels 1
Number of Slaves Up to 16 SMI slaves
Digital Inputs 2 inputs for simplified commissioning
Bit Width in Process Image Input/output: 24 bytes

Electrical and Communication

Parameter Specification
Data Transfer Standard SMI
Data Transfer Rate 2400 baud
Topology Line topology
Max. Cable Length 200 m
Input Voltage 24 V DC (-15 % / +20 %)
SMI System Voltage 230 V AC
Current Consumption K-Bus Typ. 55 mA
Electrical Isolation 500 V (K-bus / SMI-bus)
Insulation Voltage SMI bus / K-bus: 1,500 V DC; SMI bus / power contacts: 1,500 V AC

Mechanical and Environmental

Parameter Specification
Weight Approx. 80 g
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95 %, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Approvals CE

Installation Guidelines

  1. Ensure the entire control system is de-energized and locked out before beginning installation or wiring work.
  2. Inspect the BECKHOFF KL6841 Bus Terminal and its housing for any signs of transport damage.
  3. Mount the terminal onto the 35 mm DIN rail adjacent to the appropriate Bus Coupler or existing K-bus terminals, ensuring a secure mechanical lock.
  4. Verify that the K-bus connections and power contacts interlock correctly with neighboring modules.
  5. Connect the SMI line topology and field power supplies in accordance with the application wiring requirements, maintaining proper shielding and separation between low-voltage control circuits and the 230 V AC SMI network.
  6. Apply system power and verify operation using the diagnostic indicators and the TwinCAT software environment.
Loading product navigation…
Key Features:

What is the BECKHOFF KL6841 Bus Terminal and how many devices can it control?

The BECKHOFF KL6841 Bus Terminal is a specialized single-channel SMI master terminal designed for integration into modular K-bus I/O systems. It enables the direct connection, precise positioning, and status monitoring of up to 16 Standard Motor Interface slaves, such as motorized blinds and roller shutters. The device uses a standard two-wire line topology to manage data exchange securely across your building automation network.

What are the communication specifications and limits for the BECKHOFF KL6841?

The BECKHOFF KL6841 operates using the Standard Motor Interface data transfer protocol at a fixed rate of 2400 baud. It supports a maximum cable length of up to 200 meters in a line topology configuration. Additionally, it features a process image bit width of 24 bytes for both input and output data exchange.

What power supplies does the BECKHOFF KL6841 require during operation?

The BECKHOFF KL6841 requires a nominal input voltage of 24 V DC to power its internal electronics, drawing a typical K-bus current consumption of 55 mA. For the field side, it incorporates an integrated SMI system supply voltage of 230 V AC to drive the connected motor slaves. Robust electrical isolation of up to 1,500 V DC ensures safe separation between the SMI bus, K-bus, and power contacts.

What is the purpose of the onboard digital inputs on the BECKHOFF KL6841?

The BECKHOFF KL6841 is equipped with two onboard digital inputs intended to facilitate simplified local commissioning and manual override functions. These inputs allow technicians to test and verify connected actuators directly on-site before executing final parameterization. Integration into the broader control system is handled seamlessly through higher-level Bus Couplers and the TwinCAT PLC SMI library.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.