BECKHOFF

BECKHOFF KS3362 Bus Terminal

SKU KS3362

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: KS3362

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 55g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF KS3362 is a 2-channel analog input Bus Terminal designed for high-speed data logging and analysis of voltage signals in the range of -10 to +10 V. As part of the Beckhoff K-bus system, this terminal integrates high-speed data logger capabilities directly into standard I/O stations, enabling rapid transient capture and analog signal processing without requiring external specialized measuring hardware.

Featuring an integrated trigger input and 32 kbytes of internal memory, the BECKHOFF KS3362 allows for precise, event-controlled measurement cycles. This terminal distinguishes itself from standard Bus Terminals by incorporating a pluggable wiring level (KS housing), which simplifies installation, commissioning, and physical maintenance workflows by allowing pre-wired terminal blocks to be detached without disturbing the field wiring.

Features

  • Two high-speed analog input channels supporting -10 to +10 V voltage signals
  • Integrated, configurable trigger input for precise measurement initiation
  • 32 kbytes of internal memory dedicated to high-speed data logging
  • Configurable conversion times down to 10 microseconds in fast sampling mode
  • Pluggable connection level (KS-series housing) for rapid, tool-free physical replacement
  • Power supplied completely via the internal K-bus, eliminating the need for power contact routing

Applications

  • High-speed transient voltage capturing and waveform analysis
  • Dynamic machine monitoring and diagnostic recording
  • Event-triggered signal sampling in quality assurance and test bench systems
  • Fast process loop feedback in synchronized industrial automation environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model KS3362
Product Type Bus Terminal (High-Speed Data Logger)
Housing Type Pluggable wiring level
Material Polycarbonate

Signal and I/O

Number of Inputs 2 analog inputs, 1 trigger input
Signal Voltage Range -10 to +10 V
Internal Memory 32 kbytes
Resolution 14 bit + sign
Measuring Error < ±0.5% (relative to full scale value)
Internal Resistance > 500 kΩ (E1-GND, E2-GND)

Electrical and Communication

Power Supply Via the K-bus
Current Consumption K-bus Typically 120 mA
Current Consumption Power Contacts None (no power contacts present)
Bit Width in Process Image Input/Output: 2 x 16 bit data (2 x 8 bit control/status per channel)

Performance

Conversion Time < 100 microseconds (configurable down to 10 microseconds in fast sampling mode)
Trigger Function Configurable

Connection and Mechanical

Connection Technology Pluggable spring-force actuation
Solid Conductor Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Stranded Conductor Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Fine-Stranded Conductor Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Mounting 35 mm DIN rail conforming to EN 60715 with lock

Environmental and Compliance

Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
IP Rating IP20
Approvals and Markings CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)

Installation Guidelines

  1. Ensure all electrical components and power sources to the K-bus system are fully de-energized before mounting or servicing.
  2. Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, securing the lock to prevent mechanical drift.
  3. To perform wiring, utilize a small flat-blade screwdriver to actuate the spring-force terminals on the pluggable connector block.
  4. Ensure field wiring conductor insulation is stripped to the designated length of 9 to 10 mm before insertion.
  5. Verify K-bus power configuration. Because this terminal does not pass power contacts, ensure subsequent power-contact-dependent terminals on the same rail are supplied through a separate power supply terminal if required.

Replacement Recommendations

The pluggable wiring design of the BECKHOFF KS3362 simplifies replacement routines. Field-side wiring remains permanently clamped in the removable terminal block. To replace a faulty terminal, gently disconnect the pre-wired connector block from the housing, release the mechanical lock to slide the module off the DIN rail, install the replacement module, and securely re-plug the pre-wired connector. This eliminates manual rewiring and reduces potential commissioning wiring errors.

FAQ

What is the main difference between the BECKHOFF KS3362 and KL3362 Bus Terminals?

The BECKHOFF KS3362 features a pluggable wiring level (KS housing), allowing the entire terminal wiring block to be unplugged and reinserted during module replacement, whereas the KL3362 utilizes a fixed terminal housing requiring individual wires to be disconnected manually.

What range of analog inputs does the BECKHOFF KS3362 support?

The BECKHOFF KS3362 is designed to accept analog voltage signals in the range of -10 V to +10 V across 2 separate input channels.

Does the BECKHOFF KS3362 require field-side power contacts?

No, the BECKHOFF KS3362 operates without integrated power contact connections and derives its power supply entirely from the K-bus (typically drawing 120 mA).

What is the conversion rate of the BECKHOFF KS3362 Bus Terminal?

The BECKHOFF KS3362 has a standard conversion time of under 100 microseconds, which is configurable down to 10 microseconds when operating in its high-speed fast sampling mode.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.