Description

The BECKHOFF KS3362 is a 2-channel analog input Bus Terminal designed for high-speed data logging and analysis of voltage signals in the range of -10 to +10 V. As part of the Beckhoff K-bus system, this terminal integrates high-speed data logger capabilities directly into standard I/O stations, enabling rapid transient capture and analog signal processing without requiring external specialized measuring hardware.

Featuring an integrated trigger input and 32 kbytes of internal memory, the BECKHOFF KS3362 allows for precise, event-controlled measurement cycles. This terminal distinguishes itself from standard Bus Terminals by incorporating a pluggable wiring level (KS housing), which simplifies installation, commissioning, and physical maintenance workflows by allowing pre-wired terminal blocks to be detached without disturbing the field wiring.

Features

  • Two high-speed analog input channels supporting -10 to +10 V voltage signals
  • Integrated, configurable trigger input for precise measurement initiation
  • 32 kbytes of internal memory dedicated to high-speed data logging
  • Configurable conversion times down to 10 microseconds in fast sampling mode
  • Pluggable connection level (KS-series housing) for rapid, tool-free physical replacement
  • Power supplied completely via the internal K-bus, eliminating the need for power contact routing

Applications

  • High-speed transient voltage capturing and waveform analysis
  • Dynamic machine monitoring and diagnostic recording
  • Event-triggered signal sampling in quality assurance and test bench systems
  • Fast process loop feedback in synchronized industrial automation environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model KS3362
Product Type Bus Terminal (High-Speed Data Logger)
Housing Type Pluggable wiring level
Material Polycarbonate

Signal and I/O

Number of Inputs 2 analog inputs, 1 trigger input
Signal Voltage Range -10 to +10 V
Internal Memory 32 kbytes
Resolution 14 bit + sign
Measuring Error < ±0.5% (relative to full scale value)
Internal Resistance > 500 kΩ (E1-GND, E2-GND)

Electrical and Communication

Power Supply Via the K-bus
Current Consumption K-bus Typically 120 mA
Current Consumption Power Contacts None (no power contacts present)
Bit Width in Process Image Input/Output: 2 x 16 bit data (2 x 8 bit control/status per channel)

Performance

Conversion Time < 100 microseconds (configurable down to 10 microseconds in fast sampling mode)
Trigger Function Configurable

Connection and Mechanical

Connection Technology Pluggable spring-force actuation
Solid Conductor Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Stranded Conductor Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Fine-Stranded Conductor Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Mounting 35 mm DIN rail conforming to EN 60715 with lock

Environmental and Compliance

Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
IP Rating IP20
Approvals and Markings CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)

Installation Guidelines

  1. Ensure all electrical components and power sources to the K-bus system are fully de-energized before mounting or servicing.
  2. Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, securing the lock to prevent mechanical drift.
  3. To perform wiring, utilize a small flat-blade screwdriver to actuate the spring-force terminals on the pluggable connector block.
  4. Ensure field wiring conductor insulation is stripped to the designated length of 9 to 10 mm before insertion.
  5. Verify K-bus power configuration. Because this terminal does not pass power contacts, ensure subsequent power-contact-dependent terminals on the same rail are supplied through a separate power supply terminal if required.

Replacement Recommendations

The pluggable wiring design of the BECKHOFF KS3362 simplifies replacement routines. Field-side wiring remains permanently clamped in the removable terminal block. To replace a faulty terminal, gently disconnect the pre-wired connector block from the housing, release the mechanical lock to slide the module off the DIN rail, install the replacement module, and securely re-plug the pre-wired connector. This eliminates manual rewiring and reduces potential commissioning wiring errors.

Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the main difference between the BECKHOFF KS3362 and KL3362 Bus Terminals?
The BECKHOFF KS3362 features a pluggable wiring level (KS housing), allowing the entire terminal wiring block to be unplugged and reinserted during module replacement, whereas the KL3362 utilizes a fixed terminal housing requiring individual wires to be disconnected manually.
What range of analog inputs does the BECKHOFF KS3362 support?
The BECKHOFF KS3362 is designed to accept analog voltage signals in the range of -10 V to +10 V across 2 separate input channels.
Does the BECKHOFF KS3362 require field-side power contacts?
No, the BECKHOFF KS3362 operates without integrated power contact connections and derives its power supply entirely from the K-bus (typically drawing 120 mA).
What is the conversion rate of the BECKHOFF KS3362 Bus Terminal?
The BECKHOFF KS3362 has a standard conversion time of under 100 microseconds, which is configurable down to 10 microseconds when operating in its high-speed fast sampling mode.
Reviews

KS3362

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF KS3362 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS3362

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 55g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KS3362 is a 2-channel analog input Bus Terminal designed for high-speed data logging and analysis of voltage signals in the range of -10 to +10 V. As part of the Beckhoff K-bus system, this terminal integrates high-speed data logger capabilities directly into standard I/O stations, enabling rapid transient capture and analog signal processing without requiring external specialized measuring hardware.

Featuring an integrated trigger input and 32 kbytes of internal memory, the BECKHOFF KS3362 allows for precise, event-controlled measurement cycles. This terminal distinguishes itself from standard Bus Terminals by incorporating a pluggable wiring level (KS housing), which simplifies installation, commissioning, and physical maintenance workflows by allowing pre-wired terminal blocks to be detached without disturbing the field wiring.

Features

  • Two high-speed analog input channels supporting -10 to +10 V voltage signals
  • Integrated, configurable trigger input for precise measurement initiation
  • 32 kbytes of internal memory dedicated to high-speed data logging
  • Configurable conversion times down to 10 microseconds in fast sampling mode
  • Pluggable connection level (KS-series housing) for rapid, tool-free physical replacement
  • Power supplied completely via the internal K-bus, eliminating the need for power contact routing

Applications

  • High-speed transient voltage capturing and waveform analysis
  • Dynamic machine monitoring and diagnostic recording
  • Event-triggered signal sampling in quality assurance and test bench systems
  • Fast process loop feedback in synchronized industrial automation environments

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model KS3362
Product Type Bus Terminal (High-Speed Data Logger)
Housing Type Pluggable wiring level
Material Polycarbonate

Signal and I/O

Number of Inputs 2 analog inputs, 1 trigger input
Signal Voltage Range -10 to +10 V
Internal Memory 32 kbytes
Resolution 14 bit + sign
Measuring Error < ±0.5% (relative to full scale value)
Internal Resistance > 500 kΩ (E1-GND, E2-GND)

Electrical and Communication

Power Supply Via the K-bus
Current Consumption K-bus Typically 120 mA
Current Consumption Power Contacts None (no power contacts present)
Bit Width in Process Image Input/Output: 2 x 16 bit data (2 x 8 bit control/status per channel)

Performance

Conversion Time < 100 microseconds (configurable down to 10 microseconds in fast sampling mode)
Trigger Function Configurable

Connection and Mechanical

Connection Technology Pluggable spring-force actuation
Solid Conductor Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Stranded Conductor Cross-Section 0.08 to 1.5 mm² (AWG 28 to 16)
Fine-Stranded Conductor Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Mounting 35 mm DIN rail conforming to EN 60715 with lock

Environmental and Compliance

Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
IP Rating IP20
Approvals and Markings CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)

Installation Guidelines

  1. Ensure all electrical components and power sources to the K-bus system are fully de-energized before mounting or servicing.
  2. Mount the terminal onto a standard 35 mm DIN rail conforming to EN 60715, securing the lock to prevent mechanical drift.
  3. To perform wiring, utilize a small flat-blade screwdriver to actuate the spring-force terminals on the pluggable connector block.
  4. Ensure field wiring conductor insulation is stripped to the designated length of 9 to 10 mm before insertion.
  5. Verify K-bus power configuration. Because this terminal does not pass power contacts, ensure subsequent power-contact-dependent terminals on the same rail are supplied through a separate power supply terminal if required.

Replacement Recommendations

The pluggable wiring design of the BECKHOFF KS3362 simplifies replacement routines. Field-side wiring remains permanently clamped in the removable terminal block. To replace a faulty terminal, gently disconnect the pre-wired connector block from the housing, release the mechanical lock to slide the module off the DIN rail, install the replacement module, and securely re-plug the pre-wired connector. This eliminates manual rewiring and reduces potential commissioning wiring errors.

Loading product navigation…

What is the main difference between the BECKHOFF KS3362 and KL3362 Bus Terminals?

The BECKHOFF KS3362 features a pluggable wiring level (KS housing), allowing the entire terminal wiring block to be unplugged and reinserted during module replacement, whereas the KL3362 utilizes a fixed terminal housing requiring individual wires to be disconnected manually.

What range of analog inputs does the BECKHOFF KS3362 support?

The BECKHOFF KS3362 is designed to accept analog voltage signals in the range of -10 V to +10 V across 2 separate input channels.

Does the BECKHOFF KS3362 require field-side power contacts?

No, the BECKHOFF KS3362 operates without integrated power contact connections and derives its power supply entirely from the K-bus (typically drawing 120 mA).

What is the conversion rate of the BECKHOFF KS3362 Bus Terminal?

The BECKHOFF KS3362 has a standard conversion time of under 100 microseconds, which is configurable down to 10 microseconds when operating in its high-speed fast sampling mode.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...