  • Manufacturer: BECKHOFF

  • Product No.: KS6001

  • Country of origin:Germany

  • Product Type: Serial Interface Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Operating as a dedicated serial interface within the Beckhoff I/O framework, this Beckhoff KS6001 Bus Terminal enables the direct integration of RS232-compatible devices into the control network. It establishes a robust bi-directional connection, facilitating full-duplex data transmission through RxD and TxD channels with high electromagnetic interference immunity. The module features pluggable wiring levels, allowing rapid field installation and maintenance without disrupting the existing terminal wiring setup. It communicates directly with the controller through the K-bus, offering an isolated, compact footprint for industrial serial communication.

Features

  • Pluggable Connection Design: Features a removable wiring tier for fast servicing and drop-in channel replacements.
  • High Noise Immunity: Electrically isolated signals protect the internal K-bus architecture from electrical surges up to 500 V.
  • Flexible Process Image: Configurable bit-width structures in the process image (up to 5 x 8-bit user data) to accommodate variable protocol lengths.
  • Integrated Data Buffers: Equipped with a 128-byte receive buffer and a 16-byte transmit buffer to handle continuous serial data streams.
  • Rugged DIN-Rail Mounting: Direct installation onto standard 35 mm DIN rails with integrated lock mechanisms.

Applications

  • Integration of legacy barcode scanners, printers, and operator panels into EtherCAT or Lightbus networks.
  • Point-to-point communication with analytical laboratory instruments and industrial weighing scales.
  • Interfacing with proprietary serial sensor arrays and legacy telecommunication modems in power distribution panels.

Technical Specifications

Parameter Value / Specification
Manufacturer Beckhoff Automation
Model / Part Number KS6001
Technology RS232 serial interface
Data Transfer Channels 2 (1 transmit / 1 receive), TxD and RxD, full duplex
Data Transfer Rates 1200 to 19,200 baud (Default: 9600 baud, 8 data bits, no parity, 1 stop bit)
Bit Distortion Less than 3 percent
Maximum Cable Length 15 meters
Signal Voltage Range Logical 0: -18 V to -3 V | Logical 1: 3 V to 18 V
Current Consumption (K-bus) Typical 55 mA
Electrical Isolation 500 V (K-bus to signal voltage)
Data Buffers 128 bytes receive buffer, 16 bytes transmit buffer
Process Image Bit Width Input/Output: 3 x 8-bit user data, 1 x 8-bit control/status (up to 5 x 8-bit user data)
Wiring Connection Solid conductor (e), flexible (f), ferrule (a); spring-actuated clamp
Connection Cross-Section 0.08 to 1.5 mm2 (AWG 28 to 16)
Stripping Length 9 to 10 mm
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Operating / Storage Temp. 0 to +55 degC / -25 to +85 degC
Relative Humidity 95 percent, non-condensing
Protection Rating IP20 / variable installation position
Approvals & Markings CE, UL, ATEX (II 3 G Ex nA IIC T4 Gc)
Country of Origin Germany
Shipping Weight (Calculated) 1.5 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The KS6001 module is functionally identical to the standard KL6001 terminal. The critical differentiator lies in the pluggable connection block on the KS series, which permits hot-swapping or physical component replacement without requiring the field wires to be individually disconnected. Both models use the identical TwinCAT process image, making them completely interchangeable from a software and program mapping perspective.

Application Pitfalls & Engineering Notes

Because this module utilizes standard RS232 single-ended signals, maximum physical cable runs must be restricted to 15 meters to prevent signal attenuation and susceptibility to external electromagnetic fields. If the module is deployed in close proximity to high-frequency AC variable frequency drives (VFDs) or heavy inductive loads, you must run double-shielded, low-capacitance cabling directly to the terminal, terminating the shield at a dedicated functional ground busbar external to the module.

Commissioning & Wiring Tips

When configuring the serial parameters in TwinCAT System Manager, verify that the baud rate, parity, data bits, and stop bits precisely match your connected end device. A mismatch will fail to establish communication and may lock up the internal buffers. When designing the logic, monitor the 1-byte control/status process image to implement proper software handshaking, since this terminal does not utilize hardware CTS/RTS handshaking lines.

Installation Guidelines

CRITICAL WARNING

Prior to installing or removing the terminal block, completely isolate the system power supply. Ensure all auxiliary voltages feeding the terminal and any associated field instruments are fully de-energized. Failure to isolate power can result in terminal damage, system communication faults, or spark ignition risks in hazardous ATEX zones.

1

Mount the module onto a standard 35 mm DIN rail (conforming to EN 60715). Ensure the rear lock slides securely over the rail profiles.

2

Align the terminal side-by-side with adjacent K-bus terminals to engage the integrated double slot and key connection points on the housing sides.

3

Strip wire insulation back by exactly 9 to 10 mm. Use a small screwdriver flat blade to open the spring clamp mechanics on the pluggable wiring block, insert the conductor, and release to secure.

4

Plug the wired connector block back into the module housing. Turn on system power and initiate configuration within your PLC system environment.

Loading product navigation…

Can the KS6001 terminal be used in hazardous locations?

Yes, the module is certified under ATEX requirements with the Ex marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas when mounted in an appropriately rated enclosure.

What is the key functional difference between the KS6001 and the KL6001?

The KS6001 contains a removable, pluggable terminal block for quick physical swap-outs, whereas the KL6001 utilizes a permanently integrated terminal block where wires must be individual released for replacement.

How do I configure the baud rate and transmission parameters for this interface?

All configurations, including baud rates from 1200 to 19,200 baud, parity, and data bits, are mapped and configured via the Beckhoff TwinCAT System Manager software or through register programming via the controller.

What size wire conductors can be connected to the terminal clamp?

The spring-actuated clamp accepts solid conductors, flexible conductors, and conductors with ferrules ranging from 0.08 to 1.5 mm2 (AWG 28 to AWG 16).

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...