Danfoss

Danfoss 060G1371 Industrial Pressure Transmitter

SKU 060G1371

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G1371

  • Country of origin:United States

  • Product Type: Controles Industriales Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 060G1371 (060G1371) is a high-precision pressure transmitter engineered for demanding industrial automation environments. Designed to provide reliable feedback in heavy-duty applications—including hydraulic systems, cooling loops, and water distribution networks—this instrument converts process pressure into a stable 4-20 mA analog signal. By offering consistent monitoring for central PLCs and Distributed Control Systems (DCS), the 060G1371 enables real-time optimization of pump performance and valve operation, significantly reducing the risk of fluid hammer, cavitation, and unexpected plant downtime.

Technical Configuration

The hardware features a piezoresistive sensing element housed within a durable, acid-resistant body. To ensure operational stability, the electronics are factory-calibrated with a fixed configuration, isolating the signal from drift caused by mechanical resonance or vibration. The module includes integrated signal clipping diagnostics, bounding the output between 3.6 mA and 22.4 mA; this allows control systems to instantly differentiate between valid process fluctuations and wiring faults or circuit shorts. The entire assembly is protected by an IP65-rated enclosure, which shields internal circuitry from splashing water, ambient humidity, and airborne contaminants.

Technical Specifications

Feature Specification
Model 060G1371
Brand Danfoss
Pressure Range 0 to 25 bar
Output Signal 4-20 mA
Accuracy +/- 0.5% (Typical) / +/- 1.0% (Max)
Overload Pressure 50 bar
Process Connection G 1/4 Male (EN 837)
Operating Temp -40 to 100 deg C
Electrical Connector Pg 11 Angular
Ingress Protection IP65
Weight Approx 1.5 kg

FAQs

How do the clipping levels assist with system diagnostics?

The transmitter restricts output to a 4-20 mA band. Values shifting to 3.6 mA or 22.4 mA indicate a hardware or wiring failure. Because these are outside the standard operating range, your controller can flag a specific sensor fault without mistaking it for a legitimate pressure change.

Does this model require field adjustment of zero or span?

No. This unit features a factory-calibrated, non-adjustable internal configuration. This design prevents signal drift caused by continuous vibration and eliminates the risk of unauthorized field modifications, ensuring long-term measurement stability.

Is the unit suitable for outdoor or humid environments?

Yes, the 060G1371 is rated IP65, providing a robust barrier against moisture, splashing water, and dust ingress. Ensure the angular connector is correctly seated and the housing screw is tightened to maintain this environmental seal.

What is the correct wiring polarity?

The transmitter utilizes a 2-pin interface: connect the positive power supply to Pin 1 and the shared negative return path to Pin 2 on the Pg 11 angular connector.

Mechanical Installation & Wiring Protocols

  • Process Port Mounting: Thread the G 1/4 male fitting into a port counter-bored to EN 837 specifications. Use a calibrated torque wrench on the 27 mm hex base to achieve the required tightness. Do not apply rotational force to the upper cylindrical body during installation, as this can damage the internal seal joints.

  • Acoustic and Shock Mitigation: In setups featuring fast-cycling hydraulic loops or high-frequency piston pumps, integrate an upstream dampening orifice or siphon loop. While the sensor safely accommodates 50 bar surges, continuous exposure to cavitation peaks can degrade the structural integrity of the diaphragm over time.

  • Electrical Termination: Ensure the perimeter rubber seal within the angular connector sits flush inside the cap before securing the retaining screw. This is critical for preserving the IP65 environmental rating.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.