Danfoss

Danfoss 060G2115 AKS 33 Pressure Transmitter

SKU 060G2115

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G2115

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 157g

  • Shipping port: Xiamen

  • Warranty: 12 months

The 060G2115 is a high-precision AKS 33 Pressure Transmitter from Danfoss, specifically developed for the refrigeration and air conditioning industry. This sensor provides reliable pressure measurement using a 4–20 mA output signal and is engineered to function across a wide range of environmental and medium temperatures. Its robust IP65-rated enclosure and sealed gauge reference ensure consistent performance even in challenging industrial refrigeration applications.

Features

  • Optimized for refrigeration and air conditioning systems
  • Sealed gauge pressure reference for precise measurement consistency
  • Standard 4–20 mA current output for easy PLC/DCS integration
  • Wide operational temperature range: -40 degC to 85 degC
  • Durable IP65 enclosure rating protecting against dust and moisture
  • Standard EN 175301-803-A electrical connection

Technical Specifications

Feature Specification
Manufacturer Danfoss
Part Number 060G2115
Type AKS 33
Output Signal 4 – 20 mA (Current)
Pressure Reference Sealed gauge
Max. Overload Pressure 40 bar / 580 psi
Enclosure Rating IP65
Electrical Connection Angular (EN 175301-803-A)
Compensated Temp. Range 0 – 80 degC
Medium/Ambient Temp. Range -40 – 85 degC
Net Weight 0.157 Kg
Shipping Weight 1 Kg

Installation Guidelines

  • Mounting: Install the transmitter in an area where the pressure pulses are dampened. For refrigeration systems, mount the sensor in a position that prevents oil from settling in the pressure port.
  • Orientation: While the device is robust, mounting it vertically with the electrical connection facing upward or sideways is recommended to prevent moisture accumulation in the connector.
  • Wiring: Use high-quality shielded twisted-pair cables for the 4–20 mA signal. Connect the shield to the common ground at the controller end only to avoid ground loops.
  • Sealing: Ensure the connector gasket is properly seated before tightening the angular connector to maintain the IP65 rating.
  • Calibration: Ensure the controller input matches the 4–20 mA range of the transmitter to avoid measurement offsets.

FAQ

What is the output signal range of the 060G2115 transmitter?

This transmitter provides a standard 4–20 mA current output signal.

Is this transmitter suitable for outdoor refrigeration use?

Yes, it is rated IP65 and handles medium and ambient temperatures between -40 degC and 85 degC.

What is the maximum overload pressure for this unit?

The maximum overload pressure is 40 bar (580 psi).

What electrical connection standard does it utilize?

It utilizes an angular connector conforming to the EN 175301-803-A standard.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely