Danfoss

Danfoss 060G2051 AKS 33 Pressure Transmitter

SKU 060G2051

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G2051

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 152g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Danfoss 060G2051 (AKS 33) pressure transmitter is a precision-engineered sensor designed for high-reliability monitoring in industrial refrigeration and air conditioning systems. The 060G2051 utilizes advanced piezoresistive technology to provide accurate signal output, serving as a critical component in process control loops to monitor refrigerant pressures. By delivering a stable 4 to 20 mA signal, this transmitter minimizes measurement drift, ensuring optimal system performance and reducing the likelihood of catastrophic equipment failure in critical cooling infrastructure.

Technical Configuration

The AKS 33 series is designed to handle demanding physical and chemical stresses inherent in industrial process environments:

  • Sensing Technology: Utilizes a laser-calibrated piezoresistive sensing element for high linearity and thermal stability.
  • Output Protocol: Provides a standard 4 to 20 mA analog output, offering high noise immunity over long cable runs.
  • Connection Standard: Features an industry-standard EN 175301-803-A angular connector, facilitating easy integration and field maintenance.
  • Media Compatibility: Optimized for a wide range of refrigerants (including ammonia and HFCs) and capable of withstanding extreme ambient conditions ranging from -40 to 85 Celsius.
  • Pressure Reference: Configured as a sealed gauge transmitter, ensuring internal integrity even when exposed to fluctuating external atmospheric pressures.

Technical Specifications

Feature Specification
Model 060G2051 (AKS 33)
Brand Danfoss
Output Signal 4 to 20 mA
Pressure Reference Sealed gauge
Max Overload Pressure 55 bar (798 psi)
Enclosure Rating IP65
Electrical Connection EN 175301-803-A (Angular)
Ambient Temp Range -40 to 85 deg C
Compensated Temp Range 0 to 80 deg C
Net Weight 0.152 kg
Shipping Weight 1 kg

FAQs

Is the AKS 33 transmitter compatible with ammonia (R717) systems?

Yes, the AKS 33 is specifically designed for high compatibility with various refrigerants, including ammonia, due to its stainless steel wetted parts.

What is the significance of the 4-20 mA output in this transmitter?

The 4-20 mA current loop is the industrial standard for transmitting sensor data over long distances because it is highly resistant to electromagnetic interference and allows for simple cable break detection.

Does the 060G2051 require calibration after installation?

No, the device is factory-calibrated for high accuracy. However, periodic verification against a master gauge is recommended in safety-critical applications.

Installation and Operational Guidelines

  • Pressure Pulsations: In systems with high pressure transients or rapid compressor cycling, install a pulsation damper or a restrictor orifice at the pressure port to prevent mechanical fatigue of the sensor diaphragm.
  • Electrical Installation: Use shielded cable for the 4-20 mA signal loop. Connect the cable shield to the ground terminal only at the controller side to avoid creating ground loops, which can induce measurement noise.
  • Seal Integrity: The IP65 rating relies on the correct installation of the angular connector gasket. Ensure the gasket is seated properly and the central screw is tightened to the specified torque to prevent moisture ingress.
  • Orientation: While the sensor can be mounted in any orientation, it is recommended to install it in a vertical position with the pressure connection pointing downward to prevent accumulation of debris or oil in the sensing chamber.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...