Danfoss

Danfoss 132L6111 iC2-30 Frequency Converter

SKU 132L6111

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 132L6111

  • Country of origin:United States

  • Product Type: Frequency Converter

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Danfoss 132L6111 is an iC2-30 Frequency Converter designed for precise motor speed control in industrial applications. As an air-cooled frequency converter, this unit provides efficient performance for single-phase power systems, supporting a mains voltage range of 200-240 V AC. The 132L6111 is engineered to deliver a rated current of 4.2 A, ensuring reliable operation for various machinery and process control tasks.

This drive is built with an IP20/Open type protection rating and complies with C1 EMC category standards, making it suitable for integration into control panels or environments where electromagnetic compatibility is required. The 132L6111 model does not feature an integrated brake chopper, focusing its design on standard variable speed drive applications.

Features

  • Compact air-cooled design for efficient thermal management
  • Single-phase input power configuration
  • Rated output current of 4.2 A
  • Wide mains voltage compatibility (200-240 V AC)
  • IP20/Open type enclosure for panel-mounted systems
  • C1 category EMC filtering for sensitive industrial environments

Applications

  • Pump and fan speed control
  • Conveyor system regulation
  • Packaging machinery
  • HVAC system components
  • Material handling equipment

Technical Specifications

Feature Specification
Manufacturer Danfoss
Model 132L6111
Series iC2-30
Product Type Frequency converter (Air cooled)
Input Phases Single-phase
Mains Voltage 200-240 V AC
Current Rating 4.2 A
Enclosure Rating IP20/Open type
EMC Category C1
Integrated Brake Chopper No
Weight 0.985 kg
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Install the frequency converter in a vertical position within an electrical cabinet to ensure adequate airflow for the air-cooled system.
  • Clearance: Maintain minimum spacing above and below the unit as specified in the official manual to prevent thermal throttling.
  • Wiring: Ensure proper grounding of the 132L6111 chassis to the main PE bus to maintain C1 EMC compliance.
  • Environment: Protect the IP20 unit from dust, moisture, and extreme temperatures; use an external enclosure if the installation site environment is not clean.
  • Cabling: Use shielded motor cables to minimize electromagnetic interference, especially given the C1 EMC category rating.

FAQ

What is the rated current for the 132L6111?

The rated current for this frequency converter is 4.2 A.

Does this model include a built-in brake chopper?

No, the 132L6111 does not have an integrated brake chopper.

What is the ingress protection rating of this converter?

This unit has an IP20/Open type protection rating.

Is the 132L6111 designed for single-phase or three-phase power?

It is designed for single-phase power input (200-240 V AC).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.