Danfoss

131L9864 Danfoss VLT HVAC Basic Drive FC-101 2.2kW Frequency Converter

SKU 131L9864

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 131L9864

  • Country of origin:United States

  • Product Type: FC-101P2K2T4E20H4

  • Payment: T/T, Western Union

  • Weight: 5500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 131L9864 (131L9864) is a high-efficiency VLT® HVAC Basic Drive FC-101 designed by Danfoss to provide precision motor control for 2.2 kW (3.0 HP) applications. Engineered specifically for the HVAC sector, this frequency converter optimizes the performance of pumps, fans, and compressors in commercial and industrial building automation systems. By utilizing advanced variable speed technology, the 131L9864 significantly reduces energy consumption and mechanical wear on drive components. Its compact IP20 enclosure is designed for efficient cabinet integration, while the integrated H4 RFI filter ensures electromagnetic compatibility (Class A1/C2), making it a reliable choice for mission-critical ventilation and climate control infrastructures.

Suffix Breakdown

The model code FC-101P2K2T4E20H4 follows a modular logic that defines its core operational parameters:

  • FC: Part of the VLT® HVAC Drive family.

  • 101: Specifically the 101 series (HVAC Basic Drive).

  • P2K2: Represents a power rating of 2.2 kW / 3.0 HP.

  • T4: Three-phase input configured for 380 - 480 VAC mains voltage.

  • E20: Protection rating of IP20 (Chassis/Open type), requiring installation in a control panel.

  • H4: Integrated RFI filter compliant with Class A1 (Category C2) standards for reduced electromagnetic interference.

Technical Specifications

Feature Specification
Model 131L9864
Brand Danfoss
Series VLT® HVAC Basic Drive FC-101
Power Output 2.2 kW / 3.0 HP
Mains Voltage 380 - 480 VAC (3-phase)
Enclosure Rating IP20 / Chassis
RFI Category Class A1 (C2) Integrated
Operating Temp -10 to 50 deg C (with derating)
Efficiency >96%
Net Weight 5.5 kg
Shipping Weight 7.5 kg

Technical FAQs

Does the 131L9864 support communication with building management systems (BMS)?

Yes. The FC-101 series comes standard with built-in HVAC protocols including BACnet, Modbus RTU, and FC Protocol. This allows the 131L9864 to seamlessly integrate with central controllers for remote monitoring and automated energy management.

Is an external filter required to meet industrial EMC standards?

This unit includes an integrated H4 (Class A1/C2) RFI filter. For most industrial and commercial installations, no additional filtering is required to meet electromagnetic emission standards, provided that shielded motor cables are installed correctly.

What are the cooling requirements for this 2.2 kW drive?

The 131L9864 is air-cooled. For IP20 chassis models, ensure the control cabinet has sufficient airflow to keep the ambient temperature below 40 deg C for full-rated performance. Operation up to 50 deg C is possible with calculated current derating.


Engineering & Installation Guide

  • Vertical Mounting & Airflow: To ensure proper convection through the heat sink, the drive must be mounted vertically. Maintain at least 100 mm of free space above and below the unit. The FC-101 supports side-by-side mounting ("bookstyle"), which allows for high-density installation in compact electrical panels.

  • Cable Shielding Protocols: To utilize the benefits of the H4 RFI filter, use screened (shielded) motor cables. The shield must be connected to the metal decoupling plate of the drive using a 360-degree clamp to effectively divert high-frequency noise to ground and protect nearby sensitive electronics.

  • Motor Protection Settings: Upon commissioning, ensure the motor nameplate data (Voltage, Frequency, Current) is accurately entered into the drive's parameter group 1-2. This allows the 131L9864 to provide thermal overload protection and optimize the VVC+ (Voltage Vector Control) for maximum torque efficiency.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.