Danfoss

Danfoss KPS79 060L310466 KPS Series Thermostat

SKU KPS79 060L310466

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: KPS79 060L310466

  • Country of origin:United States

  • Product Type: Pressure switch and Thermostat KPS

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Danfoss KPS79 060L310466 is a KPS series thermostat engineered for robust temperature control in demanding industrial applications. This KPS 79 unit utilizes a capillary tube sensing system to provide accurate switching within a defined setting range. Designed for high reliability, the device is suitable for monitoring and controlling temperature in fluid or gas systems where precise, adjustable differential control is required. The 060L310466 provides stable performance in harsh environments, ensuring effective thermal management for automated industrial processes.

Features

  • Adjustable temperature setting range of 50 to 100 Celsius.
  • Integrated adjustable mechanical differential (4 to 16 Celsius).
  • Durable capillary tube design with 2 m length.
  • High maximum sensor temperature tolerance up to 200 Celsius.
  • Suitable for use with various sensor pocket lengths for flexible installation.

Applications

  • Heating, ventilation, and air conditioning (HVAC) systems.
  • Industrial process temperature regulation.
  • Cooling water circuits.
  • Boilers and heat exchangers.
  • Compressor and pump protection.

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Model KPS79 060L310466
Series KPS
Setting Range 50 – 100 Celsius
Mechanical Differential 4 – 16 Celsius (Adjustable)
Max Sensor Temperature 200 Celsius
Capillary Tube Length 2 m
Compatible Sensor Pockets 65 mm, 75 mm, 110 mm, 160 mm
Shipping Weight 3 Kg

Installation Guidelines

  • Mounting: Ensure the thermostat enclosure is mounted in a stable location free from excessive vibration.
  • Sensor Placement: The sensor bulb must be fully immersed in the medium being monitored to ensure accurate temperature sensing. Use appropriate thermowells or pockets as specified.
  • Capillary Handling: Avoid sharp bends or kinks in the 2 m capillary tube, as this can damage the internal system and affect accuracy.
  • Calibration: After installation, verify the switching point within the 50 – 100 Celsius range and adjust the differential as required for the specific process load.
  • Environment: Protect the housing from direct exposure to corrosive substances or moisture ingress.

FAQ

What is the adjustable temperature range for the KPS79?

The setting range for this unit is between 50 Celsius and 100 Celsius.

Can the mechanical differential be adjusted on this model?

Yes, the mechanical differential is adjustable between 4 Celsius and 16 Celsius to suit specific process requirements.

What is the maximum temperature the sensor can withstand?

The maximum sensor temperature for this device is 200 Celsius.

What is the length of the capillary tube included with this unit?

This unit is equipped with a 2 meter long capillary tube.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop