Danfoss

Danfoss KPS79 060L312166 Pressure Switch and Thermostat

SKU KPS79 060L312166

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: KPS79 060L312166

  • Country of origin:United States

  • Product Type: Pressure switch and Thermostat KPS

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Danfoss KPS79 060L312166 is a high-performance Pressure Switch and Thermostat specifically engineered for industrial temperature regulation and safety monitoring. As a member of the KPS series, this device provides reliable control within a setting range of 50 to 100 degC, making it an ideal solution for critical process environments requiring consistent thermal management.

This Pressure Switch and Thermostat offers an adjustable mechanical differential between 4 and 16 degC, allowing for precise calibration to meet operational demands. Designed for durability, the unit supports a maximum sensor temperature of 200 degC. The KPS79 is configured for use with a 75 mm sensor pocket, ensuring secure and accurate thermal sensing in various industrial media.

Features

  • Adjustable setting range: 50 to 100 degC
  • Adjustable mechanical differential: 4 to 16 degC
  • High durability with a max sensor temperature of 200 degC
  • Optimized for 75 mm sensor pocket installation
  • Compact and robust design for industrial duty

Applications

  • Industrial boiler and heating systems
  • Thermal plant process monitoring
  • HVAC industrial applications
  • Cooling and heat exchange systems
  • Automated temperature control loops

Technical Specifications

Feature Specification
Manufacturer Danfoss
Model KPS79
Code No. 060L312166
Product Type Pressure Switch and Thermostat
Setting Range 50 to 100 degC
Mechanical Differential 4 to 16 degC
Max. Sensor Temperature 200 degC
Sensor Pocket Length 75 mm
Shipping Weight 3 kg

Installation Guidelines

  • Mounting: Mount the unit in a vibration-free environment to ensure the longevity of the internal switching mechanism.
  • Sensor Pocket: Ensure the 75 mm sensor pocket is installed correctly in the media stream to achieve accurate thermal contact. Use heat-conductive paste if necessary to improve response time.
  • Differential Adjustment: Calibrate the mechanical differential within the 4 to 16 degC range according to the required hysteresis for your specific application.
  • Environmental Considerations: Ensure the unit is protected from extreme environmental conditions that may exceed its operational specifications.

FAQ

What is the temperature setting range of the KPS79?

The setting range is 50 to 100 degC.

Is the mechanical differential adjustable?

Yes, the mechanical differential can be adjusted between 4 and 16 degC.

What is the maximum temperature the sensor can withstand?

The maximum sensor temperature for this model is 200 degC.

What is the recommended sensor pocket length for this unit?

This unit is designed for use with a 75 mm sensor pocket.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.