Danfoss

Danfoss VLT HVAC Drive FC-102P5K5T4E20 5.5kW

SKU 131B4220

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 131B4220

  • Country of origin:Denmark

  • Product Type: FC-102P5K5T4E20

  • Payment: T/T, Western Union

  • Weight: 9000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The FC-102P5K5T4E20 (131B4220) is a premier VLT® HVAC Drive FC 102 series frequency converter, specifically engineered by Danfoss to provide advanced control and maximum energy savings for high-end building automation systems. Delivering 5.5 kW (7.5 HP) of power, this drive is the industry standard for managing sophisticated fan, pump, and chiller applications. The FC-102P5K5T4E20 distinguishes itself from basic drives through its intelligent HVAC features, including a built-in Smart Logic Controller, multiple PID loops, and an intuitive user interface. By precisely matching motor speed to actual demand, it significantly reduces energy consumption and mechanical stress, ensuring the longevity of critical HVAC infrastructure in hospitals, data centers, and commercial complexes.

Technical Configuration

The VLT® HVAC Drive FC 102 platform is designed for seamless integration into modern smart buildings. This unit operates on a three-phase 380 - 480 VAC mains supply and is housed in a compact IP20 enclosure, optimized for high-density mounting within control cabinets. The 131B4220 is built with high-quality internal DC link reactors to minimize harmonic distortion without the need for external filters. Its hardware architecture supports a wide range of I/O configurations and high-speed communication protocols. A key functional advantage is the drive's ability to operate in "Sleep Mode," which automatically detects low-flow conditions and shuts down the motor to conserve power, while remaining ready to restart instantly upon demand.

Technical Specifications

Feature Specification
Model FC-102P5K5T4E20 (131B4220)
Brand Danfoss
Power Rating 5.5 kW / 7.5 HP
Mains Voltage 3-Phase 380 - 480 VAC
Enclosure Rating IP20 / Chassis
Drive Series FC 102 (Advanced HVAC)
Efficiency > 98%
Communication Built-in BACnet, Modbus RTU, FC Protocol
Net Weight 6.54 kg
Shipping Weight 9.0 kg

Technical FAQs

What makes the FC 102 series different from the FC 101 basic series?While both control HVAC motors, the FC-102P5K5T4E20 offers a much deeper feature set, including more advanced PID control (up to 4 internal loops), enhanced diagnostic tools, and higher modularity for fieldbus options. The FC 102 is designed for "Total Building Control" rather than simple motor speed adjustment.

Can this drive help in detecting a broken fan belt?Yes. The FC 102 includes an "End-of-Curve" and "Broken Belt" detection feature. By monitoring the relationship between power consumption and speed, the 131B4220 can trigger an alarm or stop the motor if it detects a sudden drop in load, preventing unnecessary energy waste and mechanical damage.

Is it possible to use this 5.5 kW drive on a 230 V network?No. This specific model is configured with "Mains Voltage 4," which is strictly for 380 - 480 VAC three-phase supplies. Attempting to power it with 230 V will result in an undervoltage trip, and connection to higher voltages may cause permanent damage to the internal bridge rectifier.


Engineering & Installation Guide

  • Optimized Cooling: The FC 102 series utilizes back-channel cooling to dissipate heat efficiently. For the IP20 chassis, ensure a vertical clearance of at least 100 mm above and below the 6.54 kg unit. Avoid mounting the drive directly above heat-producing components like large contactors or power supplies.

  • BMS Integration: When connecting the drive to a BACnet or Modbus network, use high-quality twisted-pair shielded cable. Ensure the drive is correctly addressed in the software to allow the Building Management System (BMS) to access the drive's energy meters and diagnostic registers for centralized reporting.

  • EMC Best Practices: To maintain the drive's low-noise profile, ensure the motor cable is shielded and that the shield is properly grounded at the drive's metal decoupling plate. Keep control signal wires (0-10V or 4-20mA) separate from power cables to prevent electromagnetic interference from causing speed fluctuations.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Denmark

Technical knowledge

Designing Current Shunt Measurements That Stay Accurate

A practical guide to current-shunt measurement covering resistor sizing, high-side and low-side placement, Kelvin sensing, error budgets, thermal effects, protection and commissioning tests.

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.