Product Overview

The AHCPU500-RS2 (AHCPU500 RS2) is a high-performance, mid-range central processing unit designed for the Delta AH Series PLC system. Serving as the intelligent core for advanced industrial machinery, this module is engineered to handle complex automation tasks with a program capacity of 32K steps and an impressive execution speed of 0.1 microseconds per LD instruction. The AHCPU500-RS2 excels in multi-axis motion control and large-scale data processing, supporting up to 768 local I/O points. Its battery-free design and integrated SD card slot for data logging make it a robust and low-maintenance solution for high-end applications in the semiconductor, textile, and food processing industries.

Technical Configuration

The AHCPU500-RS2 architecture focuses on high-speed connectivity and deterministic control. It features two built-in multi-mode communication ports supporting RS-232, RS-422, and RS-485, allowing for simultaneous high-speed data exchange (up to 921.6 kbps) with HMIs, variable frequency drives, and other MODBUS-compliant devices. The module's "PLC Link" function enables automatic data exchange across a network without complex programming. For high-precision timing and event-driven tasks, the CPU supports 256 interrupts and 2,048 timers/counters. The inclusion of a Mini-USB programming port and support for all five standard IEC 61131-3 languages (LD, SFC, FBD, IL, ST) ensures maximum flexibility for international engineering teams.

Technical Specifications

Feature Specification
Model AHCPU500-RS2
Brand Delta
Series AH Series (High-end Rack PLC)
Local I/O Points 768
Program Capacity 32K steps (128 KB)
Data Register (D/L) 16K words / 16K words
Execution Speed 0.1 micro-s (LD instruction)
Communication Ports 2 x RS-232/422/485 (Multi-mode)
Max. Baud Rate 921.6 kbps (RS-422/485)
Storage SD Card Slot (Max. 2 GB)
Programming Port Mini-USB
Function Blocks 128
RTC Function Integrated (30-day power-off retention)
Dimensions (H x W x D) 110 mm x 40 mm x 103 mm
Weight Approx. 0.4 kg (2 kg shipping weight)

Technical FAQs

Does the AHCPU500-RS2 require a battery for program retention?

No, the AHCPU500-RS2 features a battery-free design. System programs and critical data registers are stored in non-volatile memory. The Real-Time Clock (RTC) is maintained by an internal supercapacitor for up to 30 days after power is removed.

Can I expand the I/O capacity beyond the 768 local points?

The AHCPU500-RS2 is optimized for local rack control. While it supports 768 local points, for systems requiring extensive expansion across multiple backplanes or long distances, higher-tier models in the AH series or remote I/O modules via communication cards should be considered.

How does the SD card slot function in this CPU?

The SD card slot supports cards up to 2 GB and can be used for program backup, recipe storage, and historical data logging (data registers). This is particularly useful for traceability in manufacturing processes or for updating machine firmware in the field without a PC.


Engineering & Installation Guide

  • Communication Mode Selection: The RS-232/422/485 ports are multi-mode. Ensure the hardware dip switches (if applicable) and software parameter settings in ISPSoft match your physical wiring. Using RS-422/485 is recommended for longer distances or high-noise environments to take advantage of the 921.6 kbps throughput.

  • Thermal and Electrical Clearance: To ensure the 0.1 micro-s execution speed remains stable and the CPU does not overheat, maintain a minimum clearance of 50 mm above and below the AH series rack. Use a dedicated 24 VDC power supply for the backplane to prevent electrical noise from actuators from affecting the CPU logic.

  • Firmware & Online Editing: The AHCPU500-RS2 supports online editing and debugging. When performing online edits in a running system, ensure that the changes in the logic sequence will not cause mechanical interference, as the CPU updates the process image immediately upon program download.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...