Delta Electronics

Delta AHCPU520-EN CPU Module

SKU AHCPU520-EN

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Delta Electronics

  • Product No.: AHCPU520-EN

  • Country of origin:United States

  • Product Type: CPU Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Delta AHCPU520-EN is a high-performance CPU module belonging to the AH500 series, engineered to serve as the central processing unit for complex automation tasks. This CPU module offers a robust program capacity of 128K steps (512KB) and supports up to 2304 local I/O points, making it highly suitable for mid-to-large-scale industrial control systems.

Designed for modern industrial environments, the AHCPU520-EN features integrated Ethernet communication (100Mbps) for seamless network connectivity, alongside multi-mode RS-232/422/485 ports. It supports multiple programming languages including LD, SFC, FBD, IL, and ST, providing engineers with the flexibility to implement diverse control strategies. The unit also includes advanced diagnostic features, online editing, and debugging capabilities to minimize downtime. With built-in features like an SD card slot for data logging, NTP network time correction, and web/email functions, this module ensures efficient system management and communication.

Features

  • Program Capacity: 128K steps (512KB)
  • Local I/O Capacity: Up to 2304 points
  • Communication: Built-in Ethernet (100Mbps), RS-232/422/485, and Mini-USB
  • Programming Languages: LD, SFC, FBD, IL, ST
  • Data Storage: SD card slot (supports up to 2GB)
  • Performance: LD instruction at 0.1μs; 1K steps at 0.3ms
  • Maintenance: No battery required; RTC with 30-day power-off retention
  • Advanced Networking: NTP time correction, WEB/Email functions, and IP Filter
  • Diagnostics: System diagnosis, status light, and online editing/debugging

Applications

  • Large-scale factory automation systems
  • High-speed motion control and process control
  • Building automation and HVAC management
  • Data acquisition and remote monitoring systems
  • Industrial IoT (IIoT) infrastructure

Technical Specifications

Feature Specification
Manufacturer Delta
Model AHCPU520-EN
Product Type CPU Module
Program Capacity 128K steps (512KB)
Local I/O Points 2304
Internal Power Consumption 2 W
Dimensions (H x W x D) 110 x 40 x 103 mm
Execution Speed (LD) 0.1 μs
Extension Backplane 3
Weight 0.35 kg (approx.)
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Ensure the AHCPU520-EN is mounted on a compatible AH500 backplane within a well-ventilated control cabinet.
  • Grounding: Proper chassis grounding is essential to protect against electrical noise and ensure stable operation of the communication interfaces.
  • Cabling: Use shielded cables for RS-485/422 communication to maintain signal integrity over long distances.
  • Environment: Avoid installation in areas with high humidity, extreme temperatures, or excessive dust and metal particles.
  • USB/Ethernet: Use standard, high-quality cables for programming and network connection to avoid communication interruptions.

FAQ

Does the AHCPU520-EN require a battery for program retention?

No, this module does not require a battery; it features a maintenance-free design.

What is the maximum capacity for the SD card slot?

The built-in SD card slot supports a maximum capacity of 2GB.

What programming languages are supported by this module?

The AHCPU520-EN supports LD, SFC, FBD, IL, and ST programming languages.

What is the primary communication speed for the RS-422/485 port?

The RS-422/485 port supports communication speeds up to 921.6kbps.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.