Product Overview

The DVP80EH00R3 (DVP80EH00R3) is the flagship high-end Main Processing Unit within Delta’s DVP-EH3 series, offering a robust 80-point I/O density for complex industrial control. Designed for high-speed precision and large-scale automation, this AC-powered base unit features a dual-core processor that separates peripheral operations from main execution tasks, ensuring high-speed instruction processing. In demanding applications such as high-speed bottling lines, multi-axis packaging machinery, and central utility monitoring, the DVP80EH00R3 provides the necessary logic density and relay output reliability to manage extensive field devices while maintaining a compact footprint.

Technical Configuration

The architecture of the DVP80EH00R3 is optimized for sophisticated motion and sequence control. It features a high program capacity of 30k steps and provides 80 integrated I/O points, distributed between high-speed digital inputs and robust relay outputs. The "R3" designation signifies its Relay output type, which is ideal for switching high-current AC loads or interfacing with diverse voltage levels without additional isolation. For communication, the unit supports dual RS-232 and RS-485 ports with Modbus ASCII/RTU protocol support, allowing for seamless integration into HMI and SCADA networks. It also supports high-speed counters up to 200 kHz, making it suitable for precise position tracking and encoder feedback.

Technical Specifications

Parameter Specification
Model DVP80EH00R3
Brand Delta Electronics
Series DVP-EH3 Series
I/O Points 80 Points (40 Digital Inputs / 40 Relay Outputs)
Power Supply 100 to 240 VAC (50/60 Hz)
Output Type Relay
Program Capacity 30k Steps
Execution Speed LD: 0.24 microseconds
COM Ports RS-232 and RS-485 (x2)
High-Speed Counter Up to 200 kHz (on specific inputs)
Operating Temp 0 to 55 Celsius
Shipping Weight 2.0 kg

Technical FAQs

Does the DVP80EH00R3 support expansion for additional I/O?

Yes, the DVP-EH3 series is highly modular. You can connect up to 512 total I/O points by adding EH series digital, analog, or temperature expansion modules to the right side of the main unit.

What is the maximum switching frequency for the Relay outputs?

As a relay-type PLC, the switching frequency is limited by mechanical life and response time (approx. 10 ms). For high-speed PWM or pulse-train output (PTO) applications, such as servo control, a transistor-type unit (e.g., DVP80EH00T3) is required.

How does the dual-core processor benefit my application?

The dual-core architecture allows the PLC to process communication requests (HMI/SCADA) and data logging on one core while the logic execution and I/O scanning remain uninterrupted on the other, preventing "scan time jitter" during heavy network traffic.


Engineering & Installation Guide

  • Relay Protection and Longevity: When controlling inductive loads (solenoids, contactors, or motor starters) with the relay outputs, always install a snubber circuit (RC for AC loads, flyback diode for DC loads). This prevents back-EMF arcing, which protects the internal relay contacts from premature pitting and welding.

  • Wiring and Interference: To maintain the 200 kHz high-speed counter accuracy, use shielded twisted-pair cabling for input signals. Ensure the 100-240 VAC power input is wired through a dedicated isolation transformer if the local grid suffers from high-frequency noise or switching surges from large VFDs.

  • Thermal and Mounting Orientation: Always mount the unit horizontally on a 35mm DIN rail. Maintain a minimum of 50 mm clearance around all sides of the PLC. The DVP80EH00R3 uses natural convection for cooling; blocking the ventilation slots can lead to internal heat buildup and reduce the lifespan of the integrated power supply.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
AC-powered

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...