Description
Engineered for high-performance motion control applications, the Delta Electronics ASD-B2-2023-F is a robust 2.0 kW (2000W) AC servo drive belonging to the widely-implemented ASDA-B2 series. Designed to deliver precise speed, position, and torque control, this driver handles demanding industrial tasks by translating control signals into accurate mechanical movement. It accepts a nominal 220V input and accommodates advanced tuning functions to optimize motor efficiency and system responsiveness. Dual analog inputs and pulse command capabilities allow seamless integration into centralized PLC and DCS architectures across various automation environments.
Features
- Implements advanced closed-loop position, speed, and torque control algorithms.
- Supports standard pulse-train input commands for simple positioning synchronization.
- Features dual analog inputs with a voltage range of 0 to ±10 VDC for real-time speed and torque adjustments.
- Equipped with a low-pass filter smoothing strategy to reduce high-frequency mechanical resonance.
- Robust thermal management utilizing an internal cooling fan system.
Applications
- Packaging and labeling machinery
- Textile processing and weaving equipment
- Conveyor and material handling automation
- Dedicated feeder axes in manufacturing lines
- Metal processing and feeding machinery
Technical Specifications
| Manufacturer |
Delta Electronics |
| Model / Part Number |
ASD-B2-2023-F |
| Series |
ASDA-B2 |
| Rated Output Power |
2.0 kW (2000W) |
| Input Voltage and Phase |
220 VAC, 3-phase (can accommodate single-phase derated operations) |
| Control Mode |
Position / Speed / Torque |
| Analog Input Range |
0 to ±10 VDC |
| Input Resistance |
10 kOhms |
| Time Constant |
2.2 microseconds |
| Recommended Circuit Breaker |
30A |
| Recommended Fuse |
50A |
| Mounting Screw Type |
M4 x 0.7 |
| Mounting Tightening Torque |
14 kgf-cm |
| Weight |
1.72 kg |
Installation Guidelines
- Mount the drive vertically on a flat, solid surface to prevent excessive mechanical vibration and ensure proper natural airflow.
- Maintain at least 50 mm of clearance above and below the drive housing for ventilation.
- Secure the unit using standard M4 screws tightened to the specified torque of 14 kgf-cm.
- Connect a Class 3 protective ground wire (resistance below 100 Ohms) directly to the designated grounding terminal.
- Ensure all signal cables (encoder and control I/O) are shielded and routed away from high-voltage motor power lines to minimize electrical noise.