Delta Electronics

Delta Electronics DOP-112WX HMI Advanced Narrow Frame Type

SKU DOP-112WX

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Delta Electronics

  • Product No.: DOP-112WX

  • Country of origin:United States

  • Product Type: HMI Touch Screens

  • Payment: T/T, Western Union

  • Weight: 2110g

  • Dimensions: 317.4 mm x 246.4 mm x 52.7 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for industrial visualization and monitoring, the DOP-112WX operator terminal provides a high-resolution human-machine interface for machine control and factory automation networks. This unit features a 12-inch TFT LCD display designed with a narrow frame profile to maximize active screen space within compact control panels. Equipped with a high-performance Dual Core 1GHz processor, 8GB of Flash ROM, and 1GB of DDR3 RAM, the hardware facilitates rapid graphic rendering, screen transition, and efficient alarm handling.

The interface supports diverse industrial connectivity protocols via dual 100 Mbps Ethernet ports and integrated USB host/slave ports, easing integration with external PLCs and enterprise systems. A robust four-wire resistive touch interface enables dependable input even in demanding factory floor environments where operators may be wearing gloves.

Features

  • High-Resolution Display: 12-inch TFT LCD screen displaying 24-bit color at 1024 x 768 pixel resolution.
  • High-Performance Processing: Integrated Dual Core 1GHz CPU paired with 8GB Flash ROM and 1GB DDR3 RAM.
  • Dual Ethernet Ports: Two onboard 100 Mbps ports support concurrent network routing and control architectures.
  • Heavy-Duty Touchscreen: 4-wire resistive touch screen rated for over 10,000,000 physical presses.
  • Peripheral Expansion: Features one USB Host 2.0 port, one Mini USB Slave 2.0 port, and a dedicated SD card slot for expanded storage.

Applications

  • Factory automation and process monitoring systems.
  • Water treatment facilities and pumping stations.
  • HVAC controls and centralized building management systems.
  • Packaging, labeling, and material handling machinery.

Technical Specifications

Manufacturer Delta Electronics
Model/Part Number DOP-112WX
Display Type 12-inch TFT LCD
Color Depth 24-bit
Resolution 1024 x 768 Pixels
Backlight Type LED Backlight
Backlight Brightness 500 cd/m2
Backlight Lifetime 50,000 hours
Active Display Area 245.76 mm x 184.32 mm
Processor Dual Core 1GHz
Flash ROM 8 GB
System RAM DDR3 1000MHz 1 GB
Touch Panel Type 4-wire resistive (pressure-sensitive)
Ethernet Interface 2 Ports, 100M bps x 2
USB Ports 1x Mini USB Slave Ver 2.0, 1x USB Host Ver 2.0
Storage Slot 1x SD Slot
Buzzer Multi-Tone Frequency (2K Hz to 4K Hz) / 85dB
Cooling System Natural air circulation
Operating Voltage 24 VDC (-15% to +15% allowable range)
Voltage Endurance 500 VAC for 1 minute (between DC24 terminal and FG terminals)
Power Consumption Max. 16.08 W
Dimensions (W x H x D) 317.4 mm x 246.4 mm x 52.7 mm
Mounting Cutout Size 302.7 mm x 228.7 mm
Weight 2110 g

Installation Guidelines

Ensure the terminal cutout dimensions match the specified 302.7 mm x 228.7 mm panel opening. Insert the HMI through the front of the panel cutout and secure it from the rear using the provided mounting brackets, tightening to the specified torque. Standard DC supply lines must be wired to the 24 VDC terminals, and the Frame Ground (FG) terminal must be directly bonded to the main system ground to prevent electromagnetic interference. Allow sufficient clearance around the back of the enclosure to support natural convective air cooling.

FAQ

What is the screen resolution of the Delta DOP-112WX?

The DOP-112WX features a 12-inch TFT LCD display with a high-resolution screen of 1024 x 768 pixels and 24-bit color depth.

How many communication ports does the DOP-112WX HMI offer?

This unit features dual 100 Mbps Ethernet ports, one USB Host 2.0 port, and one Mini USB Slave 2.0 port for extensive network and peripheral connectivity.

What power input is required for the DOP-112WX HMI?

The DOP-112WX operates on a nominal supply voltage of 24 VDC (with an allowable range of -15% to +15%) and has a maximum power consumption of 16.08 W.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.