The Delta VFD110C43A is a high-performance AC drive belonging to the advanced C2000 series. Designed for sophisticated motor control, this model is rated for an applicable motor capacity of 11 kW (15 HP) and is engineered to operate on a 460 V three-phase power supply.
The C2000 series is recognized for its high-level vector control capabilities, providing precise torque and speed management across a wide range of industrial applications. With a rated output current of 24 A and an output capacity of 19 kVA, the VFD110C43A is built to handle dynamic load profiles, ensuring efficient energy usage and operational stability in demanding mechanical systems. Its compact 5.4 kg design allows for efficient panel space utilization while maintaining high-end control functionality.
Features
Series: C2000 (Field-oriented Control Drive)
Motor Capacity: 11 kW (15 HP)
Input Voltage: 460 V Three-phase
Output Current: 24 A
Output Capacity: 19 kVA
Control Precision: High-performance vector control for superior torque regulation
Robust Design: Standardized Version A architecture for reliable industrial performance
Applications
Pump and fan control systems
Conveyor and material handling systems
Extrusion and plastics processing
HVAC and building automation
General industrial machinery
Technical Specifications
Feature
Specification
Manufacturer
Delta
Model
VFD110C43A
Series
C2000
Product Type
AC Drive
Applicable Motor Capacity
11 kW (15 HP)
Input Voltage
460 V Three-phase
Rated Output Capacity
19 kVA
Rated Output Current
24 A
Weight
5.4 kg
Shipping Weight
7 kg
Installation Guidelines
Mounting: Install the AC drive vertically within an electrical enclosure to ensure optimal heat dissipation and prevent overheating.
Environment: Ensure the installation site is free from conductive dust, corrosive gases, and excessive vibration.
Cabling: Utilize shielded motor cables to minimize electromagnetic interference (EMI) and ensure compliance with industrial noise standards.
Grounding: Proper grounding of the drive chassis to the system’s protective earth is critical for safety and operational reliability.
Clearance: Maintain adequate spacing around the unit to facilitate sufficient airflow as required for the internal cooling mechanisms.
FAQ
What is the rated output current of the VFD110C43A?
The rated output current for this model is 24 A.
What is the motor capacity supported by this C2000 series drive?
This drive is designed for motors up to 11 kW (15 HP).
Does this drive require three-phase input power?
Yes, it is designed for a 460 V three-phase power supply.
What is the output capacity in kVA?
The rated output capacity of the VFD110C43A is 19 kVA.
Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...
Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.
Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...
Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...
A practical Micro800 commissioning workflow covering hardware checks, USB and Ethernet discovery, safe ladder testing, download risks, fault isolation, and project recovery in FactoryTalk Design...
Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.
Choosing a selection results in a full page refresh.