Product Overview

The E82EV251_2C (E82EV251K2C) is a high-precision vector frequency inverter from the established Lenze 8200-series, engineered for the efficient control of small-scale asynchronous motors. Delivering a rated power of 0.25 kW (0.34 HP), this drive is optimized for single-phase 230/240 V mains connections, making it an essential component for decentralized automation tasks such as small conveyor belts, dosing pumps, and laboratory equipment. The E82EV251_2C excels in maintaining high torque at low speeds through its advanced vector control characteristics, ensuring smooth operation across a broad frequency range of 0 to 650 Hz. Despite its current "Phase-Out" status, this German-manufactured inverter remains a critical replacement part for maintaining legacy production lines where space-saving dimensions (7.60 x 15.20 x 15.20 cm) and long-term reliability are non-negotiable requirements.

Technical Configuration

The hardware architecture of the E82EV251_2C is built for maximum power density and thermal efficiency. It accepts a 1-phase AC input (1/N/PE) and converts it to a 3-phase AC output (3/PE), allowing for the use of standard three-phase motors in environments where only single-phase power is available. The module is housed in a robust, compact enclosure weighing just 0.70 kg, designed specifically for high-density cabinet mounting. It features integrated protection against short circuits, earth faults, and motor overloading. The unit's modular interface allows for the addition of various communication or I/O function modules, providing the flexibility to integrate into basic manual control setups or more complex, bus-controlled automation networks.

Technical Specifications

Feature Specification Details
Model E82EV251_2C / E82EV251K2C
Brand Lenze
Series 8200 Vector
Input Voltage 1/N/PE AC 230/240 V
Input Current 3.4 A (50/60 Hz)
Output Power 0.25 kW / 0.34 HP
Output Current 1.7 A (3-Phase)
Output Frequency 0 to 650 Hz
Dimensions 7.60 x 15.20 x 15.20 cm
Weight 0.70 kg
Status Phase-Out / Legacy Support
Commodity Code 85044095

Technical FAQs

Can the E82EV251_2C be operated with a 50 Hz or 60 Hz input?

Yes, the inverter is designed to handle both 50 Hz and 60 Hz mains frequencies automatically, making it suitable for global industrial applications without the need for hardware modification.

What is the maximum output frequency, and is it suitable for high-speed spindles?

The unit supports an output frequency of up to 650 Hz. While this is high enough for many standard applications, ensure that your motor's bearings and balance are rated for the corresponding RPM before configuring the drive for high-frequency operation.

How do I handle a replacement if the original unit is obsolete?

As this is a "Phase-Out" model, we maintain "Brand New" and "Refurbished" original stock. Since it is a legacy 8200-series component, it is a 1:1 match for existing E82EV251K2C units, requiring only a parameter transfer to restore full machine functionality.


Engineering & Installation Guide

Mounting and Heat Management:

For optimal performance, the E82EV251_2C must be mounted vertically. Although the unit is compact, it still requires adequate airflow. Maintain a minimum vertical clearance of 100 mm above and below the inverter. If the drive is installed in a small, non-ventilated enclosure, monitor the ambient temperature to ensure it does not exceed 45 deg C, as this could trigger an internal thermal fault.

Correct Wiring for Single-Phase Input:

Ensure that the mains input is connected strictly to the 1/N/PE terminals. Never apply three-phase 400 V power to this unit, as it is rated for 230/240 V only. To reduce electromagnetic interference, use shielded motor cables and ensure the shield is bonded to the common ground rail of the cabinet using a metal EMC clamp.

Parameter Backup and Transfer:

Before decommissioning a failing unit, use a Lenze keypad module (such as the E82ZAF) to copy the parameter set. This "Standard PT" configuration can then be uploaded to the replacement E82EV251_2C in seconds, ensuring that ramp times, V/f curves, and current limits are identical to the original setup.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White Greyish White
Country of origin
Germany

Technical knowledge

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.