The EL3002 is a 2-channel analog input terminal manufactured by Beckhoff, designed for high-precision voltage measurement within EtherCAT automation systems. It processes signals in the ±10 V range with 12-bit resolution, providing reliable data for industrial monitoring and control. The module utilizes a single-ended input technology and features configurable filtering options, including FIR and IIR filters, to ensure signal integrity.

Features

  • 2-channel analog input (±10 V)
  • 12-bit resolution (16-bit internal representation)
  • Configurable input filter limit frequency (1 kHz)
  • Integrated limit value monitoring and overload status indication
  • Electrical isolation of 500 V between E-bus and field potential
  • Compact housing with signal LEDs for diagnostic feedback

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EL3002
Number of Inputs 2 (single-ended)
Signal Voltage -10 to +10 V
Resolution 12 bit
Conversion Time 0.625 ms (configurable)
Input Filter Frequency 1 kHz
Internal Resistance > 130 kΩ
Dielectric Strength Max. 30 V
Current Consumption (E-bus) Typ. 130 mA
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC

Installation Guidelines

  • DIN Rail Mounting: Secure the EL3002 onto a 35 mm DIN rail (EN 60715). Use the integrated double slot and key connection for reliable side-by-side assembly.
  • Wiring: The terminal accepts solid (0.08–2.5 mm²) and flexible (0.14–1.5 mm²) conductors. Use a screwdriver for spring-loaded terminal actuation. Strip wires to a length of 8–9 mm.
  • Environmental: The unit is IP20 rated. Ensure installation in a clean, temperature-controlled environment within the specified -25 to +60 degC range.
  • Hazardous Areas: Complies with ATEX (II 3 G Ex nA IIC T4 Gc). Ensure all local safety regulations are followed when integrating into potentially explosive atmospheres.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock: Conforms to EN 60068-2-6 / EN 60068-2-27

What is the voltage input range of the EL3002?

The EL3002 supports a signal voltage range of -10 V to +10 V.

Does the EL3002 require manual address configuration?

No, this EtherCAT terminal does not require any manual address or configuration settings.

What is the conversion time for the input signals?

The default conversion time is 0.625 ms, which is configurable by the user.

What kind of signal filtering is available?

The module features activatable FIR/IIR filters to help manage signal noise and improve measurement accuracy.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...