The EL3002 is a 2-channel analog input terminal manufactured by Beckhoff, designed for high-precision voltage measurement within EtherCAT automation systems. It processes signals in the ±10 V range with 12-bit resolution, providing reliable data for industrial monitoring and control. The module utilizes a single-ended input technology and features configurable filtering options, including FIR and IIR filters, to ensure signal integrity.

Features

  • 2-channel analog input (±10 V)
  • 12-bit resolution (16-bit internal representation)
  • Configurable input filter limit frequency (1 kHz)
  • Integrated limit value monitoring and overload status indication
  • Electrical isolation of 500 V between E-bus and field potential
  • Compact housing with signal LEDs for diagnostic feedback

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model EL3002
Number of Inputs 2 (single-ended)
Signal Voltage -10 to +10 V
Resolution 12 bit
Conversion Time 0.625 ms (configurable)
Input Filter Frequency 1 kHz
Internal Resistance > 130 kΩ
Dielectric Strength Max. 30 V
Current Consumption (E-bus) Typ. 130 mA
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC

Installation Guidelines

  • DIN Rail Mounting: Secure the EL3002 onto a 35 mm DIN rail (EN 60715). Use the integrated double slot and key connection for reliable side-by-side assembly.
  • Wiring: The terminal accepts solid (0.08–2.5 mm²) and flexible (0.14–1.5 mm²) conductors. Use a screwdriver for spring-loaded terminal actuation. Strip wires to a length of 8–9 mm.
  • Environmental: The unit is IP20 rated. Ensure installation in a clean, temperature-controlled environment within the specified -25 to +60 degC range.
  • Hazardous Areas: Complies with ATEX (II 3 G Ex nA IIC T4 Gc). Ensure all local safety regulations are followed when integrating into potentially explosive atmospheres.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock: Conforms to EN 60068-2-6 / EN 60068-2-27

FAQ

What is the voltage input range of the EL3002?

The EL3002 supports a signal voltage range of -10 V to +10 V.

Does the EL3002 require manual address configuration?

No, this EtherCAT terminal does not require any manual address or configuration settings.

What is the conversion time for the input signals?

The default conversion time is 0.625 ms, which is configurable by the user.

What kind of signal filtering is available?

The module features activatable FIR/IIR filters to help manage signal noise and improve measurement accuracy.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Germany

Technical knowledge

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.

Designing Current Shunt Measurements That Stay Accurate

A practical guide to current-shunt measurement covering resistor sizing, high-side and low-side placement, Kelvin sensing, error budgets, thermal effects, protection and commissioning tests.

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.