Lenze

EMF2181IB Lenze 8200-series ModemCAN Communication Module

SKU EMF2181IB

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Lenze

  • Product No.: EMF2181IB

  • Country of origin:Germany

  • Product Type: Variable frequency drives

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 100g

  • Dimensions: 7,60cm x 12,70cm x 2,50cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The EMF2181IB (EMF2181IB) is a specialized ModemCAN communication interface designed for the Lenze 8200 Vector series of frequency inverters. This module enables robust, long-distance data exchange and remote parameterization capabilities, allowing the inverter to interface with modem-based networks or CAN-based system buses. In industrial sectors such as remote water management, distributed HVAC systems, and large-scale agricultural automation, the EMF2181IB acts as a critical bridge for telemetry and centralized control. Its wide operating temperature range from -10 to +70 Celsius ensures stable performance in outdoor enclosures or non-climate-controlled environments. Although classified as an obsolete part since 2017, this module remains an essential component for the maintenance and repair of legacy 8200 Vector installations, providing a reliable path for system connectivity without requiring a full drive upgrade.

Technical Configuration

The EMF2181IB is engineered for versatility and ease of integration, featuring a 9-pin dual-port configuration that supports daisy-chaining or multi-node network topologies. The hardware is designed for standard DIN rail mounting, separate from the drive if necessary, and requires an external power supply of 18-30 VDC at 100 mA. This independent power architecture ensures that communication remains active even if the main inverter power is disconnected for maintenance. The module facilitates the translation of internal drive parameters into CAN-compatible data packets, supporting high-speed diagnostics and real-time control adjustments. Its compact 7.60 x 12.70 x 2.50 cm footprint and ruggedized build quality reflect Lenze's commitment to industrial-grade communication reliability.

Technical Specifications

Attribute Specification Details
Model EMF2181IB
Brand Lenze
Origin Germany
Product Range 8200-series (Vector)
Module Type ModemCAN Communication
Supply Voltage 18 - 30 VDC
Current Consumption 100 mA
Operating Temp -10 to +70 deg C
Mounting Type DIN Rail Mount
Weight 0.10 kg
Dimensions 7.60 x 12.70 x 2.50 cm
Product Status Obsolete (Legacy Support)

Technical FAQs

What is the primary function of the "ModemCAN" interface on the EMF2181IB?

The ModemCAN interface is specifically designed to allow 8200 Vector drives to communicate over distances or through modem links that standard fieldbus cables cannot reach. It provides a standardized CAN protocol layer optimized for modem transmission speeds and stability.

Can this module be mounted directly onto the 8200 Vector inverter?

Unlike standard plug-in function modules, the EMF2181IB is a DIN rail-mounted unit. It connects to the inverter via a communication cable, allowing it to be positioned optimally within the control cabinet for wiring convenience and thermal management.

Is this module compatible with the 8200 motec or 8400 series?

No. The EMF2181IB is specifically tuned for the 8200 Vector series firmware and hardware architecture. For the 8400 series, different communication modules (such as the E84AYC... series) must be utilized.


Engineering & Installation Guide

For successful deployment of the EMF2181IB, ensure the 18-30 VDC power supply is stable and free from significant ripple, as voltage fluctuations can cause communication timeouts. Use shielded twisted-pair cabling for the CAN/Modem ports to prevent electromagnetic interference from the high-power inverter output cables. When mounting on a DIN rail, ensure there is sufficient clearance for the 9-pin connectors to avoid mechanical stress on the ports. In environments subject to extreme temperatures (approaching +70 deg C), ensure the cabinet has adequate ventilation, as excessive heat can degrade the reliability of the optocouplers used for galvanic isolation. If the module is the last node in a CAN network, ensure a 120-ohm termination resistor is correctly installed across the data lines to prevent signal reflections.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 7
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...